計測器メーカーのココリサーチ
HOME
Products
Applications
Company
Technical Info.
Support
Contact
Japanese
PAGE
TOP

Application: Pinpoint Data Acquisition of Specific Signals from CAN Output Sensors

The CAN Series provides cost-effective, single-channel (1CH) CAN-to-Analog converters.
Operating on 7–60 VDC* or 5 V USB power, these compact units offer unmatched ease of use on-site. *CANL-24 operates on 7–30 VDC.

1CH / Display Only / 40ms USB Output
18,600 JPY (excl. tax)
1CH / 1ms Analog Output + 2 Alarm Outputs
53,000 JPY (excl. tax)
Easily verify outputs without a CAN analyzer. Alarm outputs trigger instantly upon anomaly detection. [Optional]
No Complex Setup
No Costly Analyzers
No Expensive Diagnostic Tools

Example: Capturing 3CH Attitude Angle Data from a Gyroscope Sensor (Roll, Pitch, Yaw Angles & Angular Velocity)

Key Capabilities

Pinpoint capture of target CAN signals without using heavy CAN analyzers
Effortless on-site testing inside prototype vehicles and field environments
Analog output with an ultra-fast update response down to 1ms
Budget-friendly, standalone 1CH unit for quick and versatile deployment
Ideal for command control via specific CAN-bus data and real-time validation of CAN output sensors
Available with Handheld Type and Ethernet Output configuration options

Selection Factors

CAN Data Conversion
User-friendly Single-Channel (1CH) Type

1ms update Analog Output & Alarm Output

Handheld models available. Optional Ethernet support
Low Cost

Economy Model CANL-24
40ms update Analog Output

Economical Data Verification

Easily and affordably check data using your existing hardware, such as data loggers or oscilloscopes (via Analog Input).

Why Choose COCORESEARCH?

Low-Cost & Simple Measurement

Eliminate the need for high-end software analyzers. Easily measure starting from a single channel (1CH). Seamlessly scale up by adding modular units when more channels are required.

1CH
Meas.

> View 1ms Response Models

> View 40ms Economy Models

Simple Configuration

Skip deep menu hierarchies typical of complex instruments. Configure settings instantly using our complimentary setup software.


PC-free external handheld configurators also available (sold separately)

> Explore Setup Software

We also provide complimentary factory pre-configuration—simply share your DBC file with us prior to shipment.

Custom Tailored Solutions

We provide full customization starting from a single unit—including multi-channel integration in customized enclosures, targeted switch wiring, and dedicated connectors. Contact us to discuss your needs.

Ex:

> Customization & OEM Options

Analog-to-CAN Converters Available

Along with CAN-to-Analog (voltage/current) and discrete alarm units, we offer a wide range of input-to-CAN solutions covering speed, angle, torque, voltage, current, resistance, strain, temperature, flow rate, and more.
Analog-to-CAN Sensor
Input
CAN
       
CAN-to-Analog CAN Volt /
Curr

> Explore Measurement Ranges

Product Introduction

Key Features
> View Full Series Lineup

16-bit Analog Output
1ms update response: supports 4–20 mA, 1–5 V, etc. Allows concurrent CAN output.
USB Type-C Connectivity
Easy configuration.
The 24** series can operate entirely via 5V USB bus power.
Discrete Alarm Outputs
2 to 4 channels. Custom conditional parameters per channel (Above / Below / Out of Range / In Range).
LINKSHIP Software (Complimentary)
Streamlined configuration profiles, value monitoring, and report printing.
Integrated Digital Display
In-line value validation directly on the device panel (Available on 2401, 2411, 2431 models).
Galvanic Isolation
Robust electrical isolation between power supply and I/O lines.

Product Lineup


CAN-24

High-Performance 1CH Solution

Analog Output
1 to 9,999 ms update rate

Power Supply
7–60 VDC / 5 V USB Power

Display 5-digit panel
Green LED option available

Dimensions W48 x H24 x D106 mm
Compact 24x48 DIN Size

DIN-rail mount compatible


CANL-24

1CH Economy Model

Analog Output
40 to 9,999 ms update rate

Power Supply
7–30 VDC / 5 V USB Power

Display 5-digit panel
Red LED only

Dimensions W48 x H24 x D106 mm
Compact 24x48 DIN Size

DIN-rail mount compatible


CAN-1801

Processes 15CH Signals under a Single CAN-ID

15CH Contact Output
Outputs discrete ON/OFF comparative criteria per channel.
Independent threshold rules configurable by channel.
NPN open collector output topology.
Response latency within 100ms.

Power Supply
9–30 VDC


Enclosure included

CAN-HD

Handheld Unit for Field Operations

1CH Input

Output
16-bit Analog (Volt/Current)
Discrete Alarm Relay
Ethernet Connectivity

Power Supply AA Batteries / AC Adapter
Configurable Ingress/Ports
BNC, M8, Terminal Blocks, etc.



Compact Multi-CH

Ultra-Lightweight for On-Vehicle Tests

Multi-CH Input Custom-Engineered Build

Output
CAN / 16-bit Analog (Volt/Curr) / Alarm Output / Ethernet / HDMI

Power Supply 8–30 VDC
Display Option Available with or without panel display
Interface Selection BNC / LAN / D-sub / Terminal Blocks



Multi-CH CAN Converter

Flexible Layouts for Channel Count & Form Factor

Multi-CH Input Custom-Engineered Build

Output
16-bit Analog (Volt/Current)
Alarm Output
Ethernet / RS-485
HDMI (Direct Monitor Output)

Power Supply 8–30 VDC
Interface Selection
BNC / LAN / D-sub / Terminal Blocks

Input Specification: CAN 2.0 Compliant

Isolate and query specific tracking rows by filtering CAN-ID parameters, data structural definitions, and byte-start string indexing profiles from the live CAN network traffic.

We provide complimentary factory pre-configuration—simply share your DBC file with us prior to shipment.

Supported Data Formats
- Single-precision Floating Point (32-bit)
- Double-precision Floating Point (64-bit)
- 16-bit Unsigned Integer (0 to 65,535)
- 16-bit Signed Integer (-32,768 to +32,767)
- 32-bit Unsigned Integer (0 to 255)
- 32-bit Signed Integer (-2,147,483,648 to +2,147,483,647)
- 8-bit Unsigned Integer (0 to 15)
- 8-bit Signed Integer (-128 to +127)
- 1-bit Digital Value Boolean (0 to 1)

Baud Rate (bps)
10k, 20k, 50k, 100k, 250k, 500k, 1 Mbps

Endian Format
- INTEL (Little Endian) /
- MOTOROLA (Big Endian)

Frame Format
- Standard (11-bit ID) /
- Extended (29-bit ID)

Upper 5-bit Identifier Masking
[Exclusive to CAN/CANL-24 models]
When evaluating Extended (29-bit) IDs, the filter allows structural detection criteria to exclude the upper 5 bits.

Reference: 29-bit Identifier Architecture used in SAE J1939 Protocols
Priority EDP Data
Page
PDU
Format
PDU
Specific
Source
Address
3 bits 1 bit 1 bit 8 bits 8 bits 8 bits
Masked Range (Upper 5 bits) Detected Target Identifier Range

Signal Interruption Detection (Bus Line Monitoring)
[Exclusive to CAN/CANL-24 models]
Automatically triggers an "OFF" state display when incoming CAN stream data stops packet routing.
Optional configurations can execute dedicated analog output safety clamping* or trip alarm status loops.
Timeout delay bounds are configurable from 1 to 999 seconds.
*Analog fault clamps are selectable between zero scale, maximum positive scale, or maximum negative scale limits.

Signal Lost

OFF Display
Analog / Alarm
Trigger Output

Smart Configuration & Logging Protocols

Simplify profile management, print comprehensive reports, and record custom CSV data streams with our free LINKSHIP utility software.
Explore LINKSHIP Software

CSV Data Logging



Set localized time polling periods. Customized logging source builds are available upon request.

Parameter Validation



Compare and validate distinct configuration tables side-by-side.

File Management & Backups



Save system configuration profiles to a local PC to prevent manual data-entry errors and trim engineering overhead.

Error Avoidance



Perform all system scaling and parameters setup in a clean UI layout, eliminating keying errors on physical hardware buttons.

Batch Deployment



Replicate a single master profile configuration file across multiple identical physical units in seconds.

Standard USB Type-C Architecture


Configuration, Live Logging, & Bus Power

*Live logging and USB power features are exclusive to the CAN/CANL-24 models.

Effortless Wiring & Mechanical Installation

Engineered for reliable field terminal operations

Detachable Plug-in Connectors
Simply wire up the terminal block layout and press into position.

Detachable Plug-in Connectors
Spring-Lock Mechanism [Standard Build]


Detachable Plug-in Connectors
M2 Screw-Lock Mechanism [Optional Type]

Fixed Integrated Connectors
[Custom-Tailored Option]


Lateral Mounting Hooks [Left/Right]
Snap housing in place without requiring dedicated tooling.




Versatile Operation Scenarios

Portable Field Testing


Deploy mobile diagnostic checks by powering the hardware unit through a laptop or tablet via USB power*. Rugged protective carrying cases (BXS-1, sold separately) are available.
*Note: For Load Cell / Strain Gauge and Pressure Transducer models (ST/STL series), external power must be supplied via the rear terminal blocks instead of the USB connector port.



Explore BXS-1 Enclosure

Control Panel Integration


The ultra-slim 24x48 mm structural body minimizes instrument rack footprint.


View 24x48 Size Dimension Sheets

DIN-Rail Installation Setup


Available with quick-mount adaptors or streamlined displayless configuration profiles.

BXF-DN2
DIN-Rail Mounting Base (Sold Separately)
Model 2451
Displayless Blind Module
Model 2431
Panel Display Module
Explore BXF-DN2 Base View 2451 / 2431 Configurations

Other Related Products Panel Meters / Signal Converters / Indicators

Product Lineup >
EX Series Series Overview >

- CAN Bus Output
- 16-bit Analog (Voltage / Current) Output
- USB-C: For easy configuration and data logging
- Alarm Signal Output / RS-485 Communication
- Free LINKSHIP Software: Supports report printing and data logging
- Dual Analog Outputs [EX48 model]
- Ethernet (LAN) Connectivity [EX48 model]

Load Cell / Strain
CAN Converters
DC Current
DC Voltage
Thermocouple
Thermistor
RTD Sensor
Resistance
Speed / Total
Torque Meter

EX48 Series

EX(L)24 Series

Full Customization Services [Please Consult Us]

Custom Solution Lineup >

■ Flexible measurement pairing & channel layout ■ Cost-efficient and user-friendly structural design ■ Parameter adjustments (custom power input, scaling voltages, specialized communication specs)
■ Available from single-unit runs ■ Calibration tailored to assembly units ■ Inspection certifications and traceability charts can be provided

Enclosed Cases

> Details

Multi-CH with Display

> Details

Multi-CH Radiation Thermometer (CAN Out)

> Details

Integrated SD Logger

> Details

Rack-Mount Modular

> Details

Handheld Custom Enclosures

> Details

Selectable Connectors, Display Configurations, & Power Sources

Connectors
Terminal Blocks
Thermocouple
Banana Plug
BNC
       
LAN
USB Type-C
D-sub
HDMI
Display Types
LCD Monitor Displayless Type External Monitor Out
Free monitor software included.
*Monitor hardware not included.
Power Sources
AC Power

DC Power
 > Contact us