Converts CAN data to analog signals |
No need for complex settings | No need for expensive CAN analyzers | No need for expensive diagnostic equipment |
|
|
CANL-2401 | Display only, Equipped with USB communication | 17,600 yen and up* [tax not included] | |
CANL-2451 | DIN rail mounting, no display, Comparator output 2 points | 19,300 yen and up* [tax not included] |
Customization is possible, built into box, multi-CH, etc.
>Customization page Can be calibrated as an embedded product. Calibration documents and traceability charts can be issued.
|
BPS | 10k, 20k, 50k, 100k, 250k, 500k, 1Mbps |
FORMAT | INTEL [Little Endian] /MOTOROLA[(Big Endian] |
FRAME | Standard, 11bit length ID / Extended. 29bit length ID |
USB |
|
Data logging, configuration, and power supply available [ USB Type-C connector ]. | |
16bit analog output |
|
0-10V/0-5V/±10V/±5V/4-20mA [Select a model] | |
Alarm output |
|
2 points / 3 points [ Depends on the model ] |
CSV logging | Compare and match set value lists | PC save and copy of set values | Prevention of misoperation | Quickly set up multiple units | ||||
Time-specified logging, such as 600 seconds, is also available. Custom logger software is also available. | Multiple lists of set values can be compared and collated. | It prevents errors in note-taking and manual entry, and reduces management effort and costs. | Settings and confirmations can be made on the PC screen, preventing misoperation of the main unit's buttons. | Even multiple units can be easily configured by simply writing the configuration data. |
USB Type-C connector standard: configuration, logging, power supply | Setup unit without LINKSHIP or PC required: Program Loader PL-5A [sold separately] *Setting only / data logging and power supply not available
|
|
Rear USB 2411 type also available. |
Simply connect the wires to the connector and plug it in by hand. Detachable Plug Connectors |
Fixed Connectors [Customized support]non-detachable |
Mounting hooks: Fixing the main body |
||||
Spring lock type [standard] |
M2 screw type [J04 option] |
|
*Not included in 2431 and 2451 types. |
Carry and measure | Built in panel | DIN rail mounting | |||||||||||
Carry PC, instrument, and cable, and measure with USB power supply. Storage case BXS-1 is also available. | 24x48 size contributes to downsizing | One-touch fixture and display-less type are available. | |||||||||||
|
CANL-24 Dimensions |
|
Specifications
Name Model |
CAN Analog Converter CANL-2401 |
||||
Input | Number of input points CAN BPS CAN FORMAT CAN FRAME Data frame Connector |
1 point [Communication standard] CAN2.0B Set from 10k / 20k / 50k / 100k / 250k / 500k / 1M bps Select from INTEL (Little Endian) / MOTOROLA (Big Endian) Select from Standard (11bit length ID) / Extended (29bit length ID) 8Byte, set the type selection and read start byte of received data Spring lock plug connector [Option] M2 screw plug connector |
|||
Calculation | Setting value memory | Nonvolatile memory (EEPROM) | |||
Display | Display Color Indicator (Numerical Display) Decimal point position Display update time Display accuracy Indicator |
Red LED 5-digit, 7-segment LED Character height 9mm / Display range:-19999 to 99999 Over indication: OL / Zero indication: Leading zero suppress Semi-fixed Decimal point position is set in program mode. [0] *****, [1] ****.* to [4] *.**** 0.3 sec (settable from 0.1 to 9.9 sec) 20ppm±1digit LED 1 point (power) |
|||
USB communication |
Communication specification Communication function Output update time |
USB2.0 (Serial port communication by USB virtual COM 230.4kbps) Writing/reading of set values/continuous output of measured values 40 to 9999ms, settable in 1ms increments |
|||
General Information |
Operating temp./humidity Power supply voltage Power consumption Isolation Withstand voltage Weight |
-10°C to +50°C / 35 to 85%RH (non-condensing) 7 to 30V DC with reverse connection protection. Power supply from USB host: 5V 3W or less Power supply / Other input/output Between each terminal of the above isolations: 500V DC between each terminal for 1 minute Approx. 60g |
|||
Analog output option |
Output signals D/A conversion method Output resolution Load resistance Output accuracy Temperature fluctuation Output scaling Output update time Input/output delay time |
[E1] 0 to 10 V, [E5] 0 to 5 V, [R1] ±10 V, [R5] ±5 V, [I1] 4 to 20 mA [Select a model] DAC conversion method 16bit (50,000 or more) [Voltage output] 4.7kΩ or more / [Current output] 300Ω or less [Voltage output] ±0.1% of FS @ 23°C / [Current output] ±0.1% of FS @ 23°C ±200ppm/℃ or less Arbitrary scaling is possible by full scale and zero scale settings 40 to 9999ms settable in 1ms increments Output update time + analog rise time 150 μs max. |
|||
Alarm [Comparator] output option |
Setting method Number of outputs Output form Output load voltage Output logic Update time |
Set in program mode 2 or 4 points [Varies depending on model.] Isolated non-contact output (photo-MOS relay) No polarity. When comparator is ON, resistance between COMP and COM: 50 Ω or less [at C2 Option] Peak AC/DC280V 100mA (resistive load) / ON resistance 50Ω or less Comparison is made with polarity (0 is greater than minus) [Over] ON when set value or more / [Under] ON when set value or less/ [Within range] ON within the set value, OFF outside the range [Out of range] ON outside the set value, OFF inside the range Depends on analog output update time setting. Response time 1ms (max) |