Applications

Worksheet thickness and travel measurement for rolling mills, etc.

- When using rollers to wind paper or roll steel, it is necessary to know the thickness of the worksheet for quality control purposes.
- The thickness of the worksheet can be detected by attaching a linear gauge to the worksheet.
- If a rotary encoder is attached to the shaft of the roller, the amount of movement (amount of winding and cutting position) can also be measured.



Pulse signal from linear gauge or encoder


CNT-49 Series

2-phase quadruple measurement


No miscounting even after repeated forward and reverse rotation


Analog output




BCD output

 

Input to oscilloscope, etc.

 

 
Input to PLC, etc.
Feedback based on measurement results


What we can do with measurement
- Input up to 4MHz (A/B phase signal 1MHz), so it can be used in combination with a high-resolution encoder.
- Scaling function allows display in arbitrary units.
- The automatic reset function can be used to measure the angle of a rotating object.
- Analog output and BCD output with 0.5ms update can be added. (Option)
- BCD output and RS-485 option can be installed at the same time as the analog output option.

Selection Points
- 0.5ms analog output update
- BCD output and RS-485 option are available
- 2-phase quadruplicated measurement supported

Products
 
Products Points Overviews

CNT-723-CAN
Pulse Counter with High-speed Analog Output

Product page 

- High-speed pulse counter with analog output for analysis
- High-speed analog output of 7.6μs (±10V, ±5V)
- Scaling function supports various units such as angle, degree, minute, second, length measurement, etc.
- Reset input/Z-phase reset input function

CNT-4921/4931
Pulse totalizer (reversible)Counter

Product page

Analog output RS-485 RS-232C BCD output Alarm output Quadruplicated measurement Scaling function Reset input Count value backup LINKSHIP compatible

- 16bit analog output with 0.5ms update
- Various options such as RS-232C/RS-485/BCD output
- Up to 4 alarm outputs can be mounted
- 46x98 size panel meter with scaling function
- LINKSHIP" compatible, which can also be set via PC

PFC-4921
Instantaneous Counter

Product page

Reset input Start input Stop inpu Analog output Quadruplicated measurement Scaling function Totalizer backup Alarm output LINKSHIP support

- Simultaneous measurement of instantaneous flowrate (L/min, etc.) and totalized flowrate (mL, etc.)
- Quadruplicated measurement function
- 16-bit analog output with fastest 1ms update
- Up to 4 alarm outputs
- 48x96 size panel meter with scaling function
- LINKSHIP" compatible for PC setting
CRM-281

2-input transfer deviation meter

Product page

2ch input Analog output Data logging Re-pulse output Quadruplicated measurement Scaling function Count value backup

- Analog output update 100μs
- Simultaneous 2-channel analog outputs for instantaneous flowrate, instantaneous flowrate difference, totalized flowrate, totalized flowrate difference, and ring counter
- Speed ratio setting