- Different speed ratios during winding can cause sagging or tearing, so the speed ratio must be measured and used for control.
- In this example, rotary encoders A and B are attached to rollers A and B, and the pulses are input to the FRM-3921 rotational speed ratio meter to measure the rotational speed ratio.
- The FRM-3921 performs high-speed calculations of speed, speed ratio [B/A], and speed ratio [(B-A)/A] for each of the 2-channel input frequencies.
FRM-3921 TDP-49 Series SPD/SPDL Series Measuring Instruments |
→ Analog Output Alarm Output CAN RS-485 etc. |
PLC・ Motor driver controllers etc. |
What we can do with measurement
- Internal calculation and output enables high-speed, high-precision measurement compared to methods that calculate with multiple measuring instruments (tachometers, etc.).
- The unique Periomatic™ calculation method enables high speed response with high accuracy to start of motion from a standstill, ultra-low speed, high speed, and sudden speed change (sudden acceleration and stop).
- Optional analog or digital output of rotation speed, rotation speed ratio, and ratio with 1ms update (FRM) is available.
- BCD output and RS-485 options can be installed simultaneously with the analog output option.
- Speed can also be managed by TDP or SPD series.
Selection Points
- Analog output update 0.1ms~(SPD), 0.5ms~(TDP), 1ms~(FRM)
- RS-485, RS-232C, CAN, Ethernet output available
- Unique Periomatic™ calculation method: High-precision, high-speed response to start of motion from standstill, ultra-low speed, high-speed, and sudden speed change (sudden acceleration, sudden stop), etc.
- Optional line driver signal support: Highly resistant to transmission noise (TDP, SPD)
Products | Points | Overviews | |
---|---|---|---|
FRM-3921 |
RS-232C Alarm output 2ch Analog output BCD output RS-485 |
- Inputs signals from 2 channels and measures the speed ratio between the channels. | |
TDP-4921/TDP-4931 |
RS-485 RS-232C Analog output Alarm output BCD output LINKSHIP support |
- 16bit analog output with 0.5ms update |
|
SPD-4801 |
RS-485 Modbus CAN Analog output Alarm output Zero shift Span shift Count Stop/Start LINKSHIP support |
- 48x96 size speed/totalizer [switchable] for frequency meter, tachometer, flowmeter, speed meter, totalizer, etc. |
|
SPD-2401 SPDL-2401 |
RS-485 Modbus CAN Analog output Alarm output Zero shift Span shift Count Stop/Start LINKSHIP support |
- 24x48 size speed/totalizer [switchable] for frequency meter, tachometer, flowmeter, speed meter, totalizer, etc. |
|
SPD-HD |
RS-485 Modbus CAN Analog output Alarm output Zero shift Span shift Count Stop/Start LINKSHIP support |
- Speed/totalizer [switchable] for frequency meter, tachometer, flowmeter, speed meter, totalizer, etc. |