Speedmeter [Frequency meter, Tachometer]/ Counter [Switchable] SPD-2401

PERIOMATICTM calculation for High accuracy and High speed response

Frequency is measured by the sensor's pulse signal and indicated and output as rpm, L/h, km/h, or any other rate you wish.

Gear Tooth Sensors   Flow sensors  Rotary encoders  Linear encoders

Customization is possible, built into box, multi-CH, etc.     Go to custumize page
Can be calibrated as an embedded product.
Calibration documents and traceability charts can be issued.
19-inch rack mounting Built into box Multi-CH with indicator HDMI output + display software With SD logger
■Selectable measurement type and number of CHs ■Convenient, easy, low cost ■Customize input power and output signals to suit your facility
CAN output 1ms update [Option]
3-wire wiring greatly reduces wiring compared to BCD
Powerful error detection system for improved noise immunity and safety

16bit analog output 0.1ms update [Option]
Resolution 50,000 or more/Full scale and zero scale settings, output zero adjustment

Alarm output 1ms update [Option] 1 to 4points [Depends on model]

USB Type-C 1ms update [standard feature] 
Data logging, setting, power supply

Input 600μHz - 1MHz, resolution 10.4ns 

Supports signals 5V Logic zero cross NPN open collector 12V Logic Customized Signals
Various options Input Isolation A/B phase input Line driver input [Please contact us for more than 1 MHz]
Flexible adjustment  Trigger Level 0-9.99V Hysteresis Select Pull-up ON/OFF  
Sensor power supply 5V/12V, other voltages are possible. [Option]

PERIOMATICTM calculation 
High accuracy from ultra-low speed to high speed. Follows sudden changes and stops.

Frequency measurement technology originally developed by COCORESEARCH

Can be used as a counter, totalizer [Switchable] 

Reasonable and easy-to-use 1CH type  Go to Low-cost version
SPD-2401 Display only, Equipped with USB communication 32,500 yen and up* [tax not included]
SPD-2451 DIN rail mounting, no display 28,100 yen and up* [tax not included]
*Reference price in Japan.

Smart configuration and logging
Setting management, report printing, and CSV logging with dedicated software LINKSHIP [free of charge]  Go to LINKSHIP page

CSV logging Compare and match set value lists PC save and copy of set values Prevention of misoperation Quickly set up multiple units
Time-specified logging, such as 600 seconds, is also available. Custom logger software is also available. Multiple lists of set values can be compared and collated. It prevents errors in note-taking and manual entry, and reduces management effort and costs. Settings and confirmations can be made on the PC screen, preventing misoperation of the main unit's buttons. Even multiple units can be easily configured by simply writing the configuration data.

USB Type-C connector standard: configuration, logging, power supply   Setup unit without LINKSHIP or PC required:
Program Loader PL-5A
  [sold separately]

  PL-5A Product Page

*Setting only / data logging and power supply not available


Rear USB 2411 type also available.
 

Easy wiring and installation On-site usability considerations

Simply connect the wires to the connector and plug it in by hand.
Detachable Plug Connectors
Fixed Connectors
[Customized support]non-detachable
Mounting hooks:
Fixing the main body

Spring lock type [standard]

M2 screw type [J04 option]


*Not included in 2431 and 2451 types.

Various ways to use

Carry and measure Built in panel DIN rail mounting
Carry PC, instrument, and cable, and measure with USB power supply. Storage case BXS-1 is also available. 24x48 size contributes to downsizing One-touch fixture and display-less type are available.

BXS-1 Overview


SPD-24 Dimensions
DIN rail attachment
[sold separately]

BXF-DN2 page
SPD-2451
Display-less type
SPD-2431
With display type

Specifications 

  Name
Model
Measuring method
Speedmeter/Counter [Switchable]
SPD-2401
PeriomaticTMB method Cycle calculation method
Input  Number of input points
Input frequency
Input resolution
Input Signal
Input method
1 point
0.0006Hz to 1.0MHz
Approx. 10.4ns (96MHz)
5V logic, zero cross, NPN open collector, 12V logic, input customized signal
Single-phase signal
[*] General-purpose
input option
Input Level and Sensitivity
5V logic

Zero-cross
NPN open collector
12V logic
Customized input
Trigger level
2.5V
0V
2.5V
6V
0-9.0V
in 10mV units
Hysteresis
±0.4V
±0.03V
±0.4V
±0.4V
Small:±0.03V, Medium : 0.4V,
Large: ±1.3V, trigger level 4.7V or lower/ ±2.6V, trigger level 4.7V or higher
  Input pulse
Input resistance

Input withstand voltage
[Small] [Medium] 0.2 μs or more   [Large] 0.3 μs or more, for both H and L levels
5V logic, zero cross, NPN open collector, and Input customized signal (trigger level 4.7V or lower): 10kΩ
12V logic, input customized signal (trigger level 4.71V or higher): 5kΩ
±30V  *Inputs and outputs are not insulated for the general-purpose input option.
[D] Line driver
input option
Input signal
Input withstand voltage
Recommended line driver
Termination resistance
Line driver signal
±25V (differential voltage)
Equivalent to AM26LS31
300Ω (standard specification)  *Input and output are isolated for the line driver input option.
[W] 2-Phase(A/B)
input option
Input Level and Sensitivity
5V logic

Zero-cross
NPN open collector
12V logic
Customized input
Trigger level
2.5V
0V
2.5V
6V
0 / 2.5 / 6V
Hysteresis
±0.4V
±0.03V
±0.4V
±0.4V
Small:±0.03V, Medium : 0.4V
  Input low-pass filter
Trigger edge
Input withstand voltage
Input connector
Sensor Power supply output[Option]
Select from OFF, 500Hz, 5kHz, 120kHz, or 800kHz
Fall
±30V
Spring lock plug connector / [J04 option] M2 screw type plug connector
[H] DC +12V±5% 60mA max / [L] DC +5V±5% 150mA max
*When USB power is supplied, sensor power is not output.
Calculation Measurement mode
Calculation rate
Frequency divider ratio
Output moving average
Dynamic PredictiveTM
Control input
 [Setting contents]


 [Operation Method]
 [Data communication]

Low cut function
Velocity meter/Frequency meter/Period meter (seconds only) /Counter
Set the reference pulse number, reference change, and speed unit time with respect to the input frequency.
1 to 60000
1 to 99
8 levels (including continuous and stop prediction) 
None or 1 point (depending on model), [D2] Option to add 2 points.
Set a function for each control input (CTL) and control from outside
Functions: hold (current/max./min. value, max. fluctuation range), zero/span shift (Count), stop Count (stop, start)
Control input ON logic (normally open, normally closed) can be set
ON when control input (CTL*) pin (ON logic) is shorted (open) to GND; setting is reflected when open (shorted).
Command control is possible via communication (USB, CAN, RS-485)
Commands set via communication cannot be released by terminal input. Reset execution is always required.
Low cut function Stop judgment at a speed lower than the set value
Display Display Color
Indicator (Numerical Display)

Decimal point position
Display update time
Display accuracy
Indicator
[Standard] SPD-2401 Red LED / [Option] SPD-2401-G Green LED
5-digit, 7-segment LED Character height 9mm / Display range:-19999 to 99999
Polarity indication: Reverse rotation -Lighted / Over indication: OL / Zero indication: Leading zero suppress
Semi-fixed Decimal point position is set in program mode. [0] *****,  [1] ****.* to [4] *.****
0.3 sec (settable from 0.1 to 9.9 sec)
20ppm ± 1 digit
LED 1 point (selected from power/ control input/ trigger/ comparator output)
USB
communication
Communication specification
Communication function
Output update time
USB2.0 (Serial port communication by USB virtual COM 230.4kbps)
Writing/reading of set values/continuous output of measured values
1 to 9999.9ms, settable in 0.1ms increments (No output when output update time is set to 1 to 9)
General
Information
Operating temp./humidity
Power supply voltage
Power consumption
Isolation
Withstand voltage
Weight
-10°C to +50°C / 35 to 85%RH (non-condensing)
7 to 60V DC with reverse connection protection. Power supply from USB host: 5V
3W or less
Power Supply/Other Input/Output
Power supply/other input/output: 500V DC between each terminal for 1 minute
Approx. 60g
CAN Option Communication specifications
Communication function
Setting item
Output update time
CAN2.0B 10 k / 20 k / 50 k / 100 k / 250 k / 500 k / 1M bps, [Format] INTEL/MOTOROLA, [Frame] 11bit/29bit
Writing/reading of set values/continuous output of measured values
CAN transmit ID, CAN receive ID
1 to 9999.9 ms (settable in 0.1 ms increments)
(When output update time is set to 1 to 9, instantaneous values are output every 1 ms.)
RS-485
communication
option
Number of connected units
Communication format
Communication method
Communication standard
Communication speed
Data format
Communication code
Communication function

32 units (max.)
2-wire multi-drop serial communication
Asynchronous
RS-485
9,600 /19,200 /38,400bps Set in program mode
Start bit: 1 bit / Stop bit: 1 bit / Data length: 8 bits / Parity bit: None
ASCII
Writing/reading set values/measurement value output (response to request command)
Modbus RTU support is available upon request.
Analog
output option
Output signals
D/A conversion method
Output resolution
Load resistance
Output accuracy
Temperature fluctuation
Output scaling
Output update time
Input/output delay time
[E1] 0 to 10 V, [E5] 0 to 5 V, [R1] ±10 V, [R5] ±5 V, [I1] 4 to 20 mA    [Select a model]
DAC conversion method
16bit (50,000 or more)
[Voltage output] 4.7kΩ or more / [Current output] 300Ω or less
[Voltage output] ±0.1% of FS @ 23°C / [Current output] ±0.1% of FS @ 23°C
±200ppm/℃ or less
Arbitrary scaling is possible by full scale and zero scale settings
0.1 to 9999.9ms settable in 0.1ms increments
Output update time + analog rise time 150 μs max.
Alarm
[Comparator]
output option
Setting method
Number of outputs

Output form


Output load voltage
Output logic



Update time
Set in program mode
2 points (or 1 point) Depends on model selection conditions.
1 point for line driver input and analog output with comparator output specification.

Isolated non-contact output (photo-MOS relay) No polarity.
When comparator operating condition is ON, resistance between COMP and COM
50 Ω or less for C2 option (2 comparator) / 100 Ω or less for C1 option ( 1 comparator)

Peak AC/DC280V 100mA (resistive load) / ON resistance 50Ω or less
Comparison is made with polarity (0 is greater than minus)
[Over] ON when set value or more / [Under] ON when set value or less/
[Within range] ON within the set value, OFF outside the range
[Out of range] ON outside the set value, OFF inside the range

Depends on analog output update time setting. Response time 1ms (max)

To the page top