Speedmeter, Frequency meter, Tachometer/ Counter [Switchable] SPD-24
Digital panel meter, Signal converter, Indicating alarm meter, Rotational pulse meter

Specifications
Option
Dimensions
Applications
Manual Downloads
Software Downloads

Compatible with pulse output type sensors *The figure below includes optional functions

Input
Pulse (frequency) output type sensors
Gear sensor
Flow sensor
 
Rotary encoder
Linear encoder

Input Pulse
・General-purpose ・A/B phase
・Line driver

・5V logic ・Zero cross ・12V logic
・NPN open collector
・Customized signal

Sensor power output
・12V/5V/others
 
Calculation
[Speed, frequency, period, totalization]

・ PeriomaticTM B method
・Moving average ・Low cut
・Hold [Current/max./min./max. fluctuation range]
・Totalization [Zero shift, span shift, stop, start]
SPD-24 series
Power supply
・7 to 60V DC
・USB power 5V
Setting
・LINKSHIP software
・Setting unit PL-5A
   
Output
・16bit analog ・Alarm
・CAN ・RS-485 ・Modbus ・USB
 
PC

 
PLC
 
Logger
Oscilloscope
 
Indicator lamps

Integral function [Switchable]

Angle
Position
Length
Flow rate
Rewind volume

Body Type

SPD-2401

Front USB


SPD-2411

Rear USB, Front waterproof gasket included


SPD-2431

DIN rail mounting, with indicator


SPD-2451

DIN rail mounting, no indicator


Customization [Minimum of 1 unit: Please consult with us]

 >View more 

■Select and combine only what you need
■Convenient, easy, and low cost
■Functional change : power supply, output voltage, communication specifications, etc.
■Calibration as an embedded product is available
■Calibration documents and traceability charts can be issued

Compact multi-CH
Flexible number of CHs

Boxed type
Easy to use and low cost

With SD logger
Logging data storage

Multi-CH CAN output
20CH, with display

Rack Mounted, Control Box

HDMI output, multi-CH

Various outputs

 See 40ms type> 

CAN output 1ms update [Option]

3-wire system greatly reduces wiring compared to BCD
Powerful error detection system for improved noise immunity and safety

SAE J1939 (DLC 8 bytes or less) Customization
Please contact us for other customizations.

 

16bit analog output 0.1ms update [Option]

Resolution 50,000 or more/Full scale and zero scale settings, output zero adjustment

Alarm output 1ms update [Option] 1 to 4points

USB Type-C 1ms update [Standard] Data logging, setting

Input 600μHz - 1MHz, resolution 10.4ns

Signals

5V Logic
Zero cross
NPN open collector
12V Logic
Customized signal

Various options

Input isolation
A/B phase input
Line driver input
 

Adjustment

Trigger Level 0-9.99V
Hysteresis select
Pull-up ON/OFF

 

Sensor power

5V
12V
Other voltage*

*Please contuct us

PERIOMATICTMcalculation High accuracy from ultra-low speed to high speed. Follows sudden changes and stops.


About PERIOMATICTM

Moving averages

Maximum 99

Low cut

Stopping judgment at speeds below the set value

Additional control inputs

[Option] HOLD, zero shift, etc.

Reasonable and easy-to-use 1CH type

 See Low-cost version > 
SPD-2401
32,500 yen and up*
Display only, Equipped with USB communication
SPD-2451
28,100 yen and up*
DIN rail mounting, no display
*Prices as of February 2024, in Japan. Tax not included
 See options and price list> 

Smart configuration and logging

Setting management, report printing, and CSV logging with dedicated software LINKSHIP [free of charge]

 LINKSHIP Page > 

CSV logging



Time-specific logging available. Custom logger software is available.

Compare set value lists



Multiple lists of set values can be compared and collated.

Save and copy of set



Prevents errors in handwriting and typing, and reduces management time and costs.

Prevention of misoperation



Settings and confirmations can be made on the PC screen, preventing misoperation of the main unit's buttons.

Quickly set up multiple units



Even multiple units can be easily configured by simply writing the configuration data.

USB Type-C connector standard:For setting / logging / power supply


Setup unit without LINKSHIP or PC required [Sold separately]



>PL-5A Product Page
*Setting only / data logging and power supply not available

Easy wiring and installation For on-site usability

Detachable Plug Connectors
Simply connect the wires to the connector and plug it in by hand.

Detachable Plug Connectors
Spring lock type [Standard]


Detachable Plug Connectors
M2 screw type [Option]

Fixed Connector
Non-detachable [Customize]


Mounting hooks
Fixing the main body


*Not included in 2431 and 2451 types

Various ways to use

Carry and measure

Carry PC, instrument, and cable, and measure with USB power supply. Storage case BXS-1 is also available.



>BXS-1 Overview

Built in panel

24x48 size contributes to downsizing


>SPD-24 Dimensions

DIN rail mounting

One-touch fixture and display-less type

BXF-DN2
DIN rail attachment[sold separately]
SPD-2451
Display-less type
SPD-2431
With display type
>BXF-DN2 page

Power supply 7 to 60V DC  Can also operate on 5V USB power supply

Isolation

General-purpose input type: power supply/other inputs/outputs
Line driver input type: power supply/frequency signal input/other inputs/outputs electrically isolated

Applications

 See more Applications > 

Instantaneous and totalized flow measurement


Instantaneous Flow Rate
Total Flow Rate

Measurement of motor rotation and belt travel


Rotation Speed
Amount of movement
Simultaneous measurement of multiple

Speed, Frequency - CAN conversion


 Model List, Options and Prices > 

Model SPD-2401 / SPD-2411 / SPD-2431 / SPD-2451
Measuring method PeriomaticTM B method [Periodic arithmetic method]
Input
Number of input points 1
Input frequency 0.0006Hz to 1.0MHz
Input resolution Approx. 10.4ns [96MHz]
Input Signal 5V logic, zero cross, NPN open collector, 12V logic, input customized signal
Input method Single-phase signal, 2-phase signal [direction signal, UP/DOWN signal]
General-purpose input type
Input Level and Sensitivity
5V logic Trigger level 2.5V Hysteresis ±0.4V
Zero-cross Trigger level 0V Hysteresis ±0.03V
NPN open collector Trigger level 2.5V Hysteresis ±0.4V
12V logic Trigger level 6V Hysteresis ±0.4V
Customized input Trigger level 0-9.0V  Can be set in 10mV increments
Hysteresis[Small]±0.03V [Medium]±0.4V [Large]±1.3V, trigger level 4.7V or lower/ ±2.6V, trigger level 4.7V or higher
Input pulse [Small] [Medium] 0.2 μs or more   [Large] 0.3 μs or more, for both H and L levels
Input resistance [5V logic] [zero cross] [NPN open collector] [Input customized signal, trigger level 4.7V or lower] 10kΩ
[12V logic] [input customized signal, trigger level 4.71V or higher] 5kΩ
Input withstand voltage ±30V *Inputs and outputs are not insulated for the general-purpose input option.
 
Line driver input Option
Input signal Line driver signal
Input withstand voltage ±25V differential voltage
Recommended line driver Equivalent to AM26LS31
Termination resistance 300Ω [standard specification]  *Input and output are isolated for the line driver input option.
 
2-Phase[A/B] input Option Switchable between 1-phase and 2-phase [A/B] signals. When single-phase input is used, input level, Trigger level, etc. are the same as for 2-phase signals.
Input Level and Sensitivity
5V logic Trigger level 2.5V
Zero-cross Trigger level 0V
NPN open collector Trigger level 2.5V
12V logic Trigger level 6V
Customized input Trigger level 0V/2.5V/6V  Hysteresis [Small]±0.03V, [Medium]±0.4V
Input pulse [Small/Medium] 0.2 μs or more, for both H and L levels
Input resistance 10kΩ
Input withstand voltage ±30V
 
Input low-pass filter Select from OFF, 500Hz, 5kHz, 120kHz, or 800kHz
Trigger edge Fall
Input connector Spring lock plug connector / [J04 option] M2 screw type plug connector
Sensor Power supply [Option] [H] DC +12V±5% 60mA max / [L] DC +5V±5% 150mA max
*When USB power is supplied, sensor power is not output.
 
Calculation
Measurement mode Velocity meter/ Frequency meter/ Period meter [Seconds only] / Counter[Totalizer]
Calculation rate Set the reference pulse number, reference change, and speed unit time with respect to the input frequency
Frequency divider ratio 1 to 60000
Output moving average 1 to 99
Dynamic PredictiveTM 8 levels [including continuous and stop prediction]
Control input None or 1 point [depending on model]   [D2] Option to add 2 points.
 [Setting contents] Set a function for each control input and control from outside
Functions  Hold [current/max./min. value, max. fluctuation range], Zero/Span shift [count], Stop/Start count
ON logic  Normally open / Normally closed
 [Operation Method] ON when control input pin [ON logic] is shorted [open] to GND; setting is reflected when open [shorted]
 [Data communication] Command control is possible via communication [USB, CAN, RS-485]
Commands set via communication cannot be released by terminal input. Reset execution is always required.
Low cut Low cut function Stop judgment at a speed lower than the set value
 
Display
Display Color [Standard] SPD-2401 Red LED
[Option]SPD-2401-G Green LED
Indicator [Numerical Display] 5-digit, 7-segment LED Character height 9mm / Display range:-19999 to 99999
Polarity indication: Reverse rotation -Lighted / Over indication: OL / Zero indication: Leading zero suppress
Decimal point position Semi-fixed Decimal point position is set in program mode. [0] *****,  [1] ****.* to [4] *.****
Display update time 0.3 sec [settable from 0.1 to 9.9 sec]
Display accuracy 20ppm ± 1 digit
Indicator [3 round LEDs] LED 1 point [selected from power/ control input/ trigger/ comparator output]
 
USB communication
Communication specification USB2.0 [Serial port communication by USB virtual COM 230.4kbps]
Communication function Writing/reading of set values/ Continuous output of measured values
Output update time 1 to 9999.9ms, settable in 0.1ms increments [No output when output update time is set to 1 to 9]
 
General Information
Operating temp./humidity -10°C to +50°C / 35 to 85%RH [non-condensing]
Power supply voltage 7 to 60V DC with reverse connection protection. Power supply from USB host: 5V
Power consumption 3W or less
Isolation Power Supply/ Other Input/Output
Withstand voltage Power supply/ Other input/output: 500V DC between each terminal for 1 minute
Weight Approx. 60g
 
CAN Option
Communication specifications CAN2.0B 10 k / 20 k / 50 k / 100 k / 250 k / 500 k / 1M bps [Format] INTEL/MOTOROLA, [Frame] 11bit/29bit
Communication function Writing/reading of set values/ Continuous output of measured values
Setting item CAN transmit ID, CAN receive ID
Output update time 1ms to 9999.9ms  settable in 0.1 ms increments
When output update time is set to 1 to 9, instantaneous values are output every 1 ms
 
RS-485 communication option Modbus RTU support is available upon request.
Number of connected units 32 units [max.]
Communication format 2-wire multi-drop serial communication
Communication method Asynchronous
Communication standard RS-485
Communication speed 9600bps / 19200bps / 38400bps Set in program mode
Data format Start bit: 1 bit / Stop bit: 1 bit / Data length: 8 bits / Parity bit: None
Communication code ASCII
Communication function Writing/reading set values/measurement value output [response to request command]
 
Analog output option
Output signals [E1] 0 - 10V [E5] 0 - 5V [R1] ±10V [R5] ±5V [I1] 4 - 20mA  [Select a model]
D/A conversion method DAC conversion method
Output resolution 16bit16bit [50,000 or more]
Load resistance [Voltage output] 4.7kΩ or more / [Current output] 300Ω or less
Output accuracy [Voltage output] ±0.1% of FS @ 23℃/ [Current output] ±0.1% of FS @ 23℃
Temperature fluctuation ±200ppm/℃ or less
Output scaling Arbitrary scaling is possible by full scale and zero scale settings
Output update time 0.1 to 9999.9ms settable in 0.1ms increments
Input/output delay time Output update time + analog rise time 150 μs max.
 
Alarm [Comparator] output option
Setting method Set in program mode
Number of outputs 2 points (or 1 point) depends on the models  1 point for line driver input and analog output with comparator output specification.
Output form Isolated non-contact output [photo-MOS relay] No polarity.
When comparator operating condition is ON, resistance between COMP and COM
50 Ω or less for C2 option [2 comparator] / 100 Ω or less for C1 option [1 comparator]
Output load voltage Peak AC/DC280V 100mA [resistive load] / ON resistance 50Ω or less
Output logic Comparison is made with polarity [0 is greater than minus]
[Over] ON when set value or more
[Under] ON when set value or less
[Within range] ON within the set value, OFF outside the range
[Out of range] ON outside the set value, OFF within the range
Update time Depends on analog output update time setting. Response time 1ms [max.]

Related products 

For flow measurement
Flow sensor list>

For rotation measurement
Gear Sensor List>

48x96 size
SPD-48 series>

Low cost type
SPDL-24 series>

Handy type
SPD-HD>

Other measurements

 View more > 
CAN analog conversion DC current DC voltage
Thermocouple [temp.] Thermistor [temp.] RTD [temp.]
Speed/Count Frequency deviation/torque Resistance

CAN, 16bit analog, Alarm, RS-485, Modbus

 Various Outputs

Smart configuration / Prevents unintentional operation

 Software LINKSHIP

USB Type-C standard equipment

 For data logging, setting

Built in box, multi-CH, and function changes, etc

 Customization


EX48


EX(L)24

 > Contuct us