Converts signals from RTD Pt100 (3-wire) sensors to CAN.
Used as CAN signal converters and CAN signal conditioners across various fields including automotive development, construction equipment, and industrial machinery.
Automatically outputs measurement data to the CAN bus at configured update intervals, enabling easy data collection.
Plant & Industrial Process Control
Fluid temperature management in reaction vessels and piping for petrochemical, pharmaceutical, and food industries

HVAC Technology
Temperature measurement in building HVAC ducts

Refrigeration & Cold Storage
Temperature monitoring in cold storage and refrigerated warehouses

Cryogenic Technology
Accuracy verification in ultra-low temperature ranges such as LNG (Liquefied Natural Gas) tanks

Precision Machinery & Electronics
Winding temperature monitoring (overheat protection) for motors, generators, and transformers

Automotive Testing
Reference temperature measurement for exhaust gas and EV battery testing

Environment, Meteorology & Calibration Standards
High-precision air thermometers for meteorological observation, temperature control for environmental chambers

For Various Applications
| Plant Piping Temperature Control |
| Food Machinery Temperature Measurement |
| Precision Temperature Control |
| Input RTD Pt100 3-wire |
|
![]() ![]() |
![]() RTD Input |
| Conversion • Moving average up to 99 • Zero shift • HOLD [Current / Max / Min / Max Peak-to-Peak] |
||
Temperature (RTD Meter)-to-CAN Converter![]() ![]() ![]() ![]() |
![]() CAN Output |
|
| CAN Bus Outputs CAN data at each update interval | |
PCs, Data Acquisition Units, Loggers, etc. ![]()
![]() |
| 3-wire wiring: Significantly reduces wiring compared to Ethernet or BCD |
| Robust error detection: High noise immunity and enhanced safety |
| SAE J1939 examples available (DLC 8 bytes or less) |
| Temperature Measurement |
| Load Cell to CAN > | ||||||||
Excitation: 2.5V / 5V / 10V | Bridge: 120 Ω / 350 Ω
|
| Current to CAN > | ||||||||
Supports ±100 μA to ±10 A
|
| Voltage to CAN > | ||||||||
Supports ±10 mV to ±70 V
|
| Resistance to CAN > | ||||
For Displacement & Resistance Output Sensors
|
| Thermistor to CAN > |
High-Precision Conversion via Proprietary Algorithm ![]() NTC Thermistor |
| TC to CAN > | |||
For Thermocouple Types K, J, R, E, T, B, N, S
|
| Speed (Freq. Pulse Input) to CAN > | ||||||||
High Precision with PeriomaticTM
|
| Angle / Position / Displacement to CAN > | ||||||||
For Length, Angle, Displacement, Flow Rate, etc.
|
| Torque (Freq. Pulse Input) to CAN > | ||||
For Torque & Fuel Mix Ratio Sensors
|
| CAN to Voltage Converters > | ||||||||
Convert CAN to Voltage or Alarm Signals
|

| CAN continuous output function Easily acquire measured values as digital data *Depending on model |
| CAN communication with updates as fast as 1 ms (Optional) |
| Examples available supporting SAE J1939 (DLC 8 bytes or less) *Please consult us |
Common Features
・Simultaneous output of 16-bit analog and CAN (1 ms) [Optional]
>| Read More > |
48 x 96 size
Analog Output / Digital Communication
1 to 9999 ms update
Power Supply
100 to 240 V AC / 9.6 to 30 V DC
Display 6 digits
Green LED type also available
Dimensions W96, H48, D99 mm
Front Buttons
Span/Zero set, Span/Zero shift, etc.

| Read More > |
Versatile 1 CH Type
Analog Output / Digital Communication
1 to 9999 ms update
Power Supply
7 to 60 V DC / 5 V USB bus power
Display 5 digits
Green LED type also available
Dimensions W48, H24, D106 mm
DIN Rail Mounting Supported

| Read More > |
Versatile 1 CH Economy Model
Analog Output / Digital Communication
40 to 9999 ms update
Power Supply
7 to 30 V DC / 5 V USB bus power
Display 5 digits
Red LED only
Dimensions W48, H24, D106 mm
DIN Rail Mounting Supported


| Read More > |
Flexible CH count, connectors, etc.
Multi-CH Input Custom product
Power Supply
8 to 30 V DC
Display
6 digits or 5 digits
| Read More > |

| Read More > |

| Read More > |

| Read More > |

| Read More > |

| Read More > |

![]() |
![]() |
![]() |
![]() |
||||
|
|
|
|
||||
![]() |
![]() |
![]() |
![]() |
||||
|
|
|
|
||||
![]() LCD Monitor |
![]() Without Display |
![]() External Monitor Output Free monitor display software*Monitor not included |
| AC |
| DC |
![]() |
![]() |
![]() |
![]() |
Configuration management, report printing, and CSV logging with free LINKSHIP software
> Go to LINKSHIP Page







Console: No PC or LINKSHIP Needed
[Sold Separately]

Pluggable Terminal Connector
Just connect wires to the plug and insert

Pluggable Terminal Connector
Spring-lock type [Standard]

Pluggable Terminal Connector
M2 screw-lock type [Optional]

Fixed Connector
[Custom Modification]

Mounting Hooks [Left/Right]
Easy tool-free attachment and removal

Front Panel Configuration & Measurement
Prevents accidental operations with Key Lock

(A) Operation Indicator LEDs
(B) Front Membrane Sheet Buttons
[Program Mode] MODE, Digit Select, Value Set, ENTER
[Measurement Mode] Span Shift, Zero Shift
Key Lock, etc.



![]() |
![]() ![]() > BXS-1 Overview |
![]() |
![]() |
|
| BXF-DN2 DIN Rail Fixture (Sold separately) |
2451 Type Without Display |
2431 Type With Display |
| > BXF-DN2 Page | > View 2451 & 2431 Details | |