- The PSA series can be used as signal converters and CAN signal conditioners to convert PWM current, current at battery charging to CAN.
- It can be used as a signal converter to CAN communication, which is used in various applications such as automobile development, construction machinery, and industrial equipment.
- The PSA series automatically outputs measured data to the CAN bus at every update time, allowing easy data collection.
Measurement Target | Measurement range ±10A, ±5A, ±2A ±1A, ±200mA ±100mA, ±20mA ±10mA, ±2mA ±1mA, ±200μA ±100μA, 4(0)-20mA →→→ Input |
Conversion | CAN Bus →→→ Data output every update time |
Data logger, etc. | ||||||
|
PSA series: measuring instrument |
|
||||||||
|
Other products that can be converted to CAN
Speed to CAN | Torque to CAN | Voltage to CAN | TC to CAN | RTD to CAN | Resistance to CAN |
SPD Series | TQ Series | PSV Series | HT Series | HT-R Series | RR Series |
See details> Gear Sensors Flow sensors Encoders |
See details> Torque Sensors Flex Fuel Sensors Uneven rotation measurement |
See details> Pressure sensors Displacement sensors Process signal (1-5V, etc.) Various voltage output type sensors |
See details> Thermocouples |
See details> RTD |
See details> Potentiometers In-circuit resistance |
Please contact us for customization to meet your needs, such as "multi-CH and multi-type measurement in a single unit" or "in an easy-to-use housing". To the Customization Page |
Examples of production: |
What we can do with measurement
- When measuring PWM current of solenoid valves or evaluating battery charge-discharge characteristics, the measured current values can be converted to CAN data.
- Converting to CAN reduces noise and wiring time when measuring multiple units.
- CAN communication can update data as fast as 1 ms.
- CAN communication automatically outputs measurement data at each update time, while non-CAN communication acquires measurement data by command response method, thus reducing program development costs (depending on the selected model).
Selection Points
Current measurement
- CAN continuous output function is used to easily acquire measured values as digital values (depending on the selected model).
- CAN communication with 1ms update is available (option)
Low price
- Low-cost version of PSAL series is also available: CAN communication is updated in 40ms.
Products | Points | Overviews | |
---|---|---|---|
PSA-4801 DC Ammeter Product page |
USB RS-485 Modbus CAN Analog output Alarm output LINKSHIP compatible |
- Suitable for real-time PWM current measurement and feedback control.
|
|
PSA-2401 DC Ammeter Product page |
USB RS-485 Modbus CAN Analog output Alarm output LINKSHIP compatible |
- Suitable for real-time PWM current measurement and feedback control. PSA-2401: With display. Panel mounting type. |
|
PSAL-2401 DC Ammeter Product page |
USB RS-485 Modbus CAN Analog output Alarm output LINKSHIP compatible |
- Suitable for real-time PWM current measurement and feedback control. PSAL-2401: With display. Panel mounting type. |