- The PSA series can be used as signal converters and CAN signal conditioners to convert PWM current, current at battery charging to CAN.
- It can be used as a signal converter to CAN communication, which is used in various applications such as automobile development, construction machinery, and industrial equipment.
- The PSA series automatically outputs measured data to the CAN bus at every update time, allowing easy data collection.
Current to CAN Conversion
Signal conditioner that converts signal input from various sensors to CAN
| Measurement Target |
Measurement range ±10A, ±5A, ±2A, ±1A, ±200mA, ±100mA, ±20mA, ±10mA, ±2mA, ±1mA, ±200μA, ±100μA, 4(0)-20mA →→→ Input |
Conversion |
CAN Bus →→→ Data output every update time |
Data logger, etc. | ||||||
|
PSA series: measuring instrument |
|
||||||||
|
||||||||||
Measurement Contents
Various applications
Other products that can be converted to CAN
| Speed to CAN | Torque to CAN | Voltage to CAN | TC to CAN | RTD to CAN | Resistance to CAN |
| SPD Series | TQ Series | PSV Series | HT Series | HT-R Series | RR Series |
See details>![]() Gear Sensors ![]() Flow sensors ![]() Encoders |
See details>![]() Torque Sensors ![]() Flex Fuel Sensors ![]() Uneven rotation measurement |
See details>![]() Pressure sensors ![]() Displacement sensors Process signal (1-5V, etc.) Various voltage output type sensors |
See details>![]() Thermocouples |
See details>![]() RTD |
See details>![]() Potentiometers ![]() In-circuit resistance |
|
Please contact us for customization to meet your needs, such as "multi-CH and multi-type measurement in a single unit" or "in an easy-to-use housing". To the Customization Page |
Examples of production:
|
What we can do with measurement
- When measuring PWM current of solenoid valves or evaluating battery charge-discharge characteristics, the measured current values can be converted to CAN data.
- Converting to CAN reduces noise and wiring time when measuring multiple units.
- CAN communication can update data as fast as 1 ms.
- CAN communication automatically outputs measurement data at each update time, while non-CAN communication acquires measurement data by command response method, thus reducing program development costs (depending on the selected model).
Selection Points
Current measurement
- CAN continuous output function is used to easily acquire measured values as digital values (depending on the selected model).
- CAN communication with 1ms update is available (option)
Low price
- Low-cost version of PSAL series is also available: CAN communication is updated in 40ms.
Products
| Products | Points | Overviews | |
|---|---|---|---|
![]() |
PSA-4801 DC Ammeter Product page |
USB RS-485 Modbus CAN Analog output Alarm output LINKSHIP compatible |
- Suitable for real-time PWM current measurement and feedback control. |
![]() |
PSA-2401 DC Ammeter Product page |
USB RS-485 Modbus CAN Analog output Alarm output LINKSHIP compatible |
- Suitable for real-time PWM current measurement and feedback control.
PSA-2401: With display. Panel mounting type. |
![]() |
PSAL-2401 DC Ammeter Product page |
USB RS-485 Modbus CAN Analog output Alarm output LINKSHIP compatible |
- Suitable for real-time PWM current measurement and feedback control.
PSAL-2401: With display. Panel mounting type. |
Related measurement keywords Signal Converter