|
|
||
|
|
||
|
|
For PC, PLC, logger, monitor, indicator light, etc.
|
|
|
|||
![]() |
![]() |
![]() |
|||
|
|
|
|||
![]() |
![]() |
![]() |
|||
|
|
||||
![]() |
![]() |
![]() |
![]() |
||
![]() Display software free of charge/ Monitor not included |
|
||||
|
||||
![]() |
![]() |
![]() |
![]() |
Change input/output to match your sensor
[E.g.]
Input: Changed to 100V
Calculation: To add a special calculation formula
Output: Change analog voltage output value or communication to match the equipment.
Change the panel design to suit the installation location, etc.
[E.g.]
Change the panel color
Print your company logo, etc.
PeriomaticTM arithmetic unit with high accuracy and fast response from ultra-low speed to high speed can be incorporated into your products.
Base model(substrate) | What is PeriomaticTM |
[E.g.]
Cost reduction by eliminating unnecessary functions of standard products
Possible to consider performance improvement of some functions
Gear sensors list |
![]() |
![]() |
![]() |
![]() |
Analog Input to CAN Output |
Request
・As an external device, convert analog signals to CAN
Customized contents
・EX series in a box W140 H35 D136 (excluding protruding parts)
・BNC for analog signals / Dsub for CAN output / Main unit power switch / AC power inlet
Advantages
・AC100-240V(Rear-inlet)/DC5V(Front-USB-C)、Either power supply can be used
・Various inputs (select model): Thermocouple / Thermistor / Resistance thermometer / Current / Voltage / Resistance / Frequency pulse (speed, angle, position / torque, frequency deviation)
Applications | Models that can be built-in |
Temperature Input |
Request
・CAN output for 12 radiation temperature sensors
Customized contents
・Banana connector 12 CH for radiation temperature sensor
・Dsub for CAN / USB-C for setting / Power switch for main unit
Advantage
・Contactless, multi-point temperature measurement
Overview | Supported models |
Request
・Thermocouple 6CH to be boxed together
Customized contents
・Input connector: thermocouple 6CH
・Output connector: Dsub for CAN, BNC for analog
Advantages
・Check all 6 channels at once on LCD display
・Output CAN and analog simultaneously
Applications | Overview | Thermocouple meter |
Request
・Thermocouple 3CH boxed and changed to front operation
Customized contents
・Input connector: thermocouple 3CH
・Output connector: BNC
・Boxing 3 thermocouple meters
Advantages
・Install 3CH in a box
・Input/Output and display are integrated on the front panel
Applications | Thermocouple meter |
Current/voltage input |
Request
・Boxing 20 ammeters (voltmeters) and CAN output
Customized contents
・Input connector: terminal block 20CH
・Output connector: Dsub for CAN
・Power switch on main unit
Advantages
・Check 20 CHs of measured values at a glance
Applications | Current-CAN converter |
Request
・Input voltage signal 20CH and CAN output
Customized contents
・Input connector: terminal block 20CH
・Dsub for CAN / USB-C for setting / Main unit power switch
Advantages
・Compact housing W126xH53xD128 *Excluding projections and legs
Applications | Overview | Voltage-CAN converter |
Request
・Output current input with CAN and voltage signal
Customized contents
・Current meter in handy case
・Specified connector/indicator attachment
Advantages
・Handy size / CAN and voltage signal, simultaneous output
Applications | Current-CAN converter |
CAN input |
Request
・CAN10CH input to voltage output
Customized contents
・CAN analog converter 10 units in a box
・Power switch on the main unit
Advantages
・Check 10 channels of CAN data at a glance
・No need for CAN analyzer
Applications | CAN to analog converter |
Request
・Can convert CAN to voltage/current signals on site
Customized contents
・Handy size housing
・2Way power supply (battery/AC adapter)
Advantages
・Can data checking/logging on site
・No need for CAN analyzer
Applications | Overview | CAN Converter |
Request
・CAN20CH for analog voltage (current) signal output
Customized contents
・Dsub for CAN input
・Terminal block for analog output / USB-C for setting / Main unit power switch
Advantages
・Compact housing W126xH53xD128 *Excluding projections and legs
・No CAN analyzer required
Applications | Overview | CAN converter |
Velocity and frequency pulse input |
Request
・4CH velocity measurement
Customized contents
・Box 4 units of speedometer SPD-2401
・Specify connector / power switch of main unit
Advantages
・Check 4CH speed at a glance / Data acquisition
・No need for CAN analyzer
Applications | Speed meter |
Request
・3CH speed measurement in a box / easy control input
Customized contents
・Control input button on the front / Power switch on the main unit
・Terminal block, BNC, Dsub connector on the back
Advantages
・Velocity 3CH at a glance / Easy data acquisition / HOLD command
Applications | Sped meter |
Request
・Boxed with handle/change input signal
Customized contents
・Supports line driver signal 2-phase input (A+, A-, B+, B-)
・Power SW and inlet for AC power supply installed on the rear panel
Advantages
・Easy to carry
・Supports 2-phase line driver signals and is resistant to noise from long-distance transmission
Applications | Speed meter |
Request
・Measure, display, and output elapsed time each time it passes a specified section
Customized contents
・Special specifications of the SPDL-2401 speedometer
・Free sample logger software
Advantages
・Display and output elapsed time (cycle) between input pulses each time the measurement target passes in front of the sensor
Applications | Overview | Speedmeter |
Totalizer/Counter Frequency pulse input |
Request
・Comparison of two types of meters
Customized contents
・Speed/totalizer [switchable type] 2 units of SPDL-2401 in a box
・Equipped with count reset switch
Advantages
・Easy comparison of two types of meters
Applications | Counters and totalizers |
Request
・Setting and control input from the front of the main unit
Customized contents
・Setting/control buttons and power switch on the front
・BNC connector and AC power inlet on the back
Advantages
・Comparison of two types of meters that easily operate counters from the front of the main unit
Applications | Counters and totalizers |
Request
・Display and output of CH1, CH2, and difference between CH1 and CH2
Customized contents
・Install 3 totalizers
・Display and output of totalizer CH1, totalizer CH2, and difference between totalizers CH1-CH2
Advantages
・Check CH1, CH2, and the difference between CH1 and CH2 at a glance
Applications | Counters and totalizers |
Others |
Request
・Thermocouple 4CH and voltage 2CH to be put together in a box
Customized contents
・Multi-CH and multi-type measurement are mixed
・Input connector example: Thermocouple 4CH, terminal block 2CH for voltage
・Output connector example: Dsub for CAN, BNC for analog
Advantages
・Check 6 channels at once on LCD display
・Output CAN and analog simultaneously
Applications | Overview | Available Models |
Request
・Display multi-CH signal on monitor
Customized contents
・Input terminal block / HDMI output connector / USB-C for setting
・Display software free of charge (monitor not included)
Advantages
・Customizable monitor display design
Applications | Overview | Available Models |
Request
・Save logging data to SD card/Start/stop logging on front panel
Customized contents
・Start/stop logging and power switch on the front
・Slot for SD card (with operation indicator LED)
・USB-C for configuration/p>
Advantages
・Start/stop logging, easy data saving
Applications | Overview | Available Models |
Request
・4CH in a small housing
Customized contents
・BNC for input / for output
Advantages
・Easy to carry / Minimize weight load when mounted in a vehicle
Applications | Available Models |
Request
・Incorporate multiple CHs in a 19-inch rack
Customized contents
・Case built-in: Panel meter, connectors, controller mounted
・Rack built-in: DIN rail mounting, no display unit
Advantages
・Mountable on existing rack units
Applications | Panel meters | For DIN rail |
Increase the number of CH |
Box many kinds |
Connector |
Oinput/output or communication |
Set to in-house sensor |
Power supply |
Panel design |
Incorporate PeriomaticTM calculation part |
Display not required |
High accuracy even at low speed |
Original transducer |
Calibration as boxed product |
Hundreds of achievements and know-how |
Developed and designed in-house |
Designed to be trouble-free |
Various measurement genres |
Manufactured in Japan |
Quick response |
Calibration and calibration documents issued* |
Traceability charts issued* |
STEP1 ![]() ![]() |
|
Inquiry of request | ![]() |
STEP2 |
|
Create specifications at | ![]() |
STEP3 |
|
Design | ![]() |
STEP4 |
|
Prototype production | ![]() |
STEP5 |
|
Mass production |