Resistance to CANs Lineup

Converts resistance values from sensors such as potentiometers into CAN data.
Useful as signal converters and CAN signal conditioners for CAN communication across various fields including automotive development, construction machinery, and industrial equipment.
Automatically outputs measurement data to the CAN bus at each update interval for seamless data collection.

Signal Conditioners that Convert Various Sensor Signals into CAN
Input

Potentiometer


Internal Resistance

150 Ω,
1.5 kΩ,
10 kΩ,
40 kΩ
 
Conversion
・Moving Average (up to 99) ・Zero Shift
・HOLD [Current / Max / Min / Max Fluctuation Width]
Resistance to CAN


CAN
Output
   
CAN Bus
CAN Data Output per Update Interval

PCs, Data Acquisition Units, Loggers, etc.

3-wire cabling significantly
reduces wiring compared to Ethernet or BCD
Powerful error detection system ensures
noise immunity and enhanced safety
SAE J1939 support available
(DLC 8 bytes or less)

Measurement Types

Resistance Measurement
Position Measurement
Angle Measurement

Diverse Applications

Internal Resistance Measurement
Position Control
Steering Angle Control

Other Various CAN Converters Available

Load Cell to CAN >

Excitation 2.5V/5V/10V, Bridge 120Ω/350Ω

Strain Gauge Load Cell Pressure Sensor Accelerometer
Current to CAN >

Supports ±100 µA to ±10 A

Battery Charging Current Solenoid PWM Current Motor Clamp-on
Sensor
Voltage to CAN >

Supports ±10 mV to ±70 V

Pressure Sensor Displacement Sensor ECU Level Sensor
Thermistor to CAN >

High-Precision Conversion via Proprietary Calculation


NTC Thermistor
TC to CAN >

For Thermocouples K, J, R, E, T, B, N, S

RTD to CAN >

Supports Pt100 RTDs

Speed Freq. Pulse Input to CAN >

High Precision with PeriomaticTM

Gear Sensor Flow Sensor Rotary
Encoder
Linear
Encoder
Angle/Position/Displacement to CAN >

Length Measurement, Angle, Displacement, Flow Rate, etc.

Gear Sensor Stroke
Sensor
Rotary
Encoder
Linear
Encoder
Torque Freq. Pulse Input to CAN >

For Torque and Fuel Mixture Ratio Sensors

Torque Sensor Flex Fuel Sensor
CAN to Voltage Converters >

Convert CAN to Voltage Signals or Alarm Signals

Automotive Construction Machinery Agricultural Machinery Office Equipment, etc.

What Can Be Achieved Through Measurement

Forklift steering angle control, stroke position control, etc.:
Converts resistance values into CAN and acquires data
Reduces noise via CAN communication,
and reduces wiring workload when using multiple units
CAN communication with update rates as fast as 1 ms
CAN communication automatically outputs measurement data at each update interval, reducing program development costs *Varies by model
(Non-CAN methods acquire measurement data via command-response mode)

Selection Key Points

CAN Output of Measurement Data

Continuous CAN Output Function
Easily acquire measurement values as digital values
Output Update: As fast as 1 ms
Support examples available for SAE J1939 (DLC 8 bytes or less), etc. *Please consult us

Low Cost

Economy Version RRL Series:
Analog output and CAN communication update in 40 ms
EXL24
To Product Page >

Lineup

Common Features

・Simultaneous output of 16-bit analog output and CAN available (1 ms) [Optional]
・Various other outputs: RS-485 / Alarm / Modbus [Optional], USB-C [Standard]
・HOLD (Current/Min/Max/Max Fluctuation Width), Span/Zero Set, and Span/Zero Shift functions
・Dedicated Software (Free): Setting management, report printing, data logging

RR-4801

 Learn More > 

48x96 Size

Analog Output & Digital Communication
1–9999 ms update

Power Supply
AC100–240 / DC9.6–30V

Display 6-digit
Green LED type also available

External Dimensions W96, H48, D99

Front Setting Buttons
Span/Zero set, span/zero shift, etc.


RR-24

 Learn More > 

Easy-to-Use 1CH Type

Analog Output & Digital Communication
1–9999 ms update

Power Supply
DC7–60V / USB Power Supply 5V

Display 5-digit
Green LED type also available

External Dimensions W48, H24, D106

DIN Rail Mounting Supported


RRL-24

 Learn More > 

Easy 1CH Economy Version

Analog Output & Digital Communication
40–9999 ms update

Power Supply
DC7–30V / USB Power Supply 5V

Display 5-digit
Red LED only

External Dimensions W48, H24, D106

DIN Rail Mounting Supported


Multi-CH Enclosed Unit

 Learn More > 

Flexible CH count, connectors, etc.

Multi-CH Input Customized product

Power Supply
DC8–30V

Display 5-digit

Selectable Connectors
BNC / LAN / D-sub / Terminal block

Customizations Available[Please Consult Us]

View All >
Flexible Measurement Types & CH Counts
Convenient, Easy, Low Cost
Function Modifications: Power Supply, Output Voltage, Communication Specs, etc.
Available Starting from a Single Unit
Calibratable as an Embedded Unit
Calibration Documents & Traceability Charts Available

Enclosed Unit

 Learn More > 

Multi-CH with Display

 Learn More > 

Multi-CH Radiation Thermometer CAN Output

 Learn More > 

With SD Logger

 Learn More > 

Rack-Mount

 Learn More > 

Handheld Type

 Learn More > 

Connectors, Display Availability, Power Supply, and More Can Also Be Selected

Connectors
Terminal Block
For Thermocouple
Banana Type
BNC
       
LAN
USB-C
D-sub
HDMI
       
Display

LCD Monitor

No Display

Monitor Display

Free Monitor Display Software
*Monitor not included
Power Supply
AC
DC

Smart Settings & Logging

Setting management, report printing, and CSV logging with dedicated software LINKSHIP (Free)

> To LINKSHIP Page

CSV Logging



Logging available by specifying seconds. Logger software customization also available

Compare & Check Settings



Compare and check multiple setting value lists

Save & Copy Settings to PC



Prevent errors from handwriting/manual entry, reducing management effort and costs

Prevent Operation & Setting Errors



Configure and check on the PC screen. Prevent unit button operation errors

Reduce Setting Workload



Copy master settings and simply write setting data across multiple units

USB Type-C Standard Equipment


Front USB: Settings, Logging & Power Supply


Settings, logging, and power supply also possible via rear terminals*. Rear USB type also available
*Settings and logging from the rear terminal block require the CAN or RS-485 option
*For load cells / pressure gauges ST(L), please supply power from the rear terminal block, not the USB connector


Rear USB: Settings & Logging


Settings also possible via front buttons or rear terminal block
*Settings and logging from the rear terminal block require the CAN or RS-485 option



Ethernet (LAN) option also available

Setting Device: No LINKSHIP or PC Required
[Sold Separately]



>To PL-5A Product Page

※Dedicated for settings / Data logging and power supply are not available.


Easy Wiring & Installation

Designed for on-site ease of use

Detachable Plug Connector
Connect wires and simply plug in

Detachable Plug Connector
Spring Lock Type [Standard]


Detachable Plug Connector
M2 Screw Type [Optional]

Fixed Connector
[Customization Available]


Mounting Hooks [Left & Right]
Easily attach/detach the unit without tools




Set & Measure from the Front
Keylock function prevents misoperation


(A) Operation Display LED
(B) Front Sheet Buttons
[Program Mode] MODE / Digit Selection / Numeric Setting / ENTER
[Measurement Mode] Span Shift / Zero Shift
Key lock, etc.



Front Panel Blue/Pink Type[Optional]
*Design is subject to change


Mounting Hooks [Left & Right]
Easily attach/detach the unit without tools

Versatile Usage Options

Portable Measurement


Carry a PC/tablet, unit, and cables, and measure with USB power supply*. Storage case BXS-1 (sold separately) also available
*For load cells / pressure gauges ST(L), please supply power from the rear terminal block, not the USB connector



>To BXS-1 Overview

Panel Integration


24x48 size contributes to downsizing


>24x48 Size Dimension Drawing

DIN Rail Mounting


One-touch mounting attachments and no-display types available

BXF-DN2
DIN Rail Attachment (Sold Separately)
2451 Type
No Display
2431 Type
With Display
>To BXF-DN2 Page >View Descriptions of 2451 & 2431