Frequency-to-CAN Converter Lineup

Convert signals from gear sensors, flow sensors, and encoders to CAN using the SPD series.
Used as signal converters and CAN signal conditioners across various fields including automotive development, construction equipment, and industrial machinery.
Automatically outputs measurement data to the CAN bus at configured update intervals, enabling easy data collection.

Signal Conditioners Converting Various Sensor Signals to CAN
Input
Pulse (Frequency) Output Sensors
Gear Sensors Flow Sensors
   
Rotary
Encoders
Linear
Encoders

Frequency
Pulses



• Logic • Zero-cross • Line driver signals
Sensor Power Supply
• 12V / 5V / Custom
 
Conversion
• Moving average up to 99 • Zero shift
• HOLD [Current / Max / Min / Max Peak-to-Peak]
Frequency-to-CAN Converter


CAN
Output
   
CAN Bus
Outputs CAN data at each update interval

PCs, Data Acquisition Units, Loggers, etc.

3-wire wiring significantly reduces wiring compared to Ethernet or BCD
Robust error detection system enhances noise immunity and safety
SAE J1939 examples available
(DLC 8 bytes or less)

Measurement Types

Speed Measurement
RPM Measurement
Frequency Measurement
Instantaneous Flow Measurement

For Various Applications

Motor Rotation Detection
Engine Speed
Film Winding Speed
Fuel Gauges

Applications & Capabilities

Converts sensor pulse signals to CAN for data acquisition in motor RPM and fuel flow measurement
Reduces noise via CAN communication and reduces wiring labor when using multiple units
CAN communication with updates as fast as 1 ms
Non-CAN communication retrieves measurement data via command-response, whereas CAN automatically outputs data at each update interval, reducing software development costs (depending on model)

Selection Points

Speed (Frequency) Measurement
CAN continuous output function
Easily acquire measured values as digital data *Depending on model

CAN communication with updates as fast as 1 ms (Optional)

Examples available supporting SAE J1939 (DLC 8 bytes or less) *Please consult us

Easy Setup

No deep menu hierarchies like multi-function devices; configure quickly with free dedicated software.


External console also available (sold separately, no PC required)

 View Setup Software > 

High Precision & Fast Response
Proprietary PeriomaticTM algorithm achieves high precision from ultra-low to high speeds. Tracks sudden changes and rapid stops



 View PeriomaticTM > 

Budget Models
Economy Series SPDL Series:
CAN communication with 40 ms updates

Input 600 μHz to 1 MHz | Input Resolution 10.4 ns

Supports Various Signals

5V Logic
Zero-cross
NPN Open Collector
12V Logic
Custom Signals

Input Options

Isolated Input
Phase A/B Input
Line Driver

Adjustable to Preference

Trigger Level 0 - 9.99 V
3 Hysteresis Levels
Pull-up ON/OFF
Trigger Level (Threshold) Variable 0 - 9.00 V
Compatible with Various Sensors

While typical measuring instruments are fixed at 2.5 V, SPD can be set from 0 to 9 V in 10 mV steps to accommodate various sensors.

or signals can be input
Threshold 0.5 V   Threshold 7 V  

Sensor Power Supply [Optional]

5V
12V
Other Voltages

Lineup

Common Features

・Simultaneous output of 16-bit analog (0.1 ms) and CAN (1 ms) [Optional]
・Various other outputs: RS-485 / Alarm / Modbus [Optional], USB-C [Standard]
・HOLD (Current / Min / Max / Max Peak-to-Peak), Span/Zero set, Span/Zero shift functions
・Free dedicated software: Configuration management, report printing, and data logging

SPD-4801

 Read More > 

48 x 96 size

Analog Output
0.1 to 9999.9 ms update

Digital Communication
1 to 9999 ms update

Power Supply
100 to 240 V AC / 9.6 to 30 V DC

Display 6 digits
Green LED type also available

Dimensions W96, H48, D99 mm

Front Setting Buttons


SPD-24

 Read More > 

Versatile 1 CH Type

Analog Output
0.1 to 9999.9 ms update

Digital Communication
1 to 9999 ms update

Power Supply
7 to 60 V DC / 5 V USB bus power

Display 5 digits
Green LED type also available

Dimensions W48, H24, D106 mm

DIN Rail Mounting Supported


SPDL-24

 Read More > 

Versatile 1 CH Economy Model

Analog Output & Digital Communication
40 to 9999 ms update

Power Supply
7 to 30 V DC / 5 V USB bus power

Display 5 digits
Red LED only

Dimensions W48, H24, D106 mm

DIN Rail Mounting Supported


Includes Case

SPD-HD

 Read More > 

Handheld Type for Field Use

Analog Output
0.1 to 9999.9 ms update

Digital Communication
1 to 9999 ms update

Power Supply AA Batteries / AC Adapter

Display OLED 16 chars x 2 lines

Dimensions W94, H32, D150 mm

Selectable Connectors
BNC / M8 / Terminal block, etc.



Multi-CH CAN Converter

 Read More > 

Flexible CH count, connectors, etc.

Multi-CH Input Custom product

Output
16-bit analog (Voltage/Current)
Alarm
Ethernet / RS-485
HDMI (for monitor output)

Power Supply 8 to 30 V DC
Selectable Connectors
BNC / LAN / D-sub / Terminal block

Smart Setup & Logging

Configuration management, report printing, and CSV logging with free LINKSHIP software

> Go to LINKSHIP Page

CSV Logging



Logging at user-specified intervals (in seconds). Custom logger software is also available.

Compare & Verify Settings



Compare and verify multiple setting parameter lists.

Save & Copy Settings to PC



Prevents manual entry errors while reducing management effort and costs.

Prevent Operational & Setting Errors



Configure and verify settings on the PC screen to avoid key-operation errors on the main unit.

Reduce Setup Man-Hours



Copy master setting data and simply write it to multiple units.

USB Type-C Standard Equipment


Front USB: Configuration, Logging, and Power Supply


Configuration, logging, and power supply are also supported via rear terminals*. Rear USB types are also available.
*Configuration and logging via rear terminals require CAN or RS-485 option.
*For Load Cell / Pressure Meters ST(L), supply power via rear terminals, not the USB connector.


Rear USB: Configuration & Logging


Configuration is also possible via front buttons or rear terminals.
*Configuration and logging via rear terminals require CAN or RS-485 option.



Ethernet (LAN) option also available

Console: No PC or LINKSHIP Needed
[Sold Separately]



> PL-5A Product Page

*Dedicated for configuration / Does not support data logging or power supply.


Easy Wiring & Mounting

Designed for Field Usability

Pluggable Terminal Connector
Just connect wires to the plug and insert

Pluggable Terminal Connector
Spring-lock type [Standard]


Pluggable Terminal Connector
M2 screw-lock type [Optional]

Fixed Connector
[Custom Modification]


Mounting Hooks [Left/Right]
Easy tool-free attachment and removal




Front Panel Configuration & Measurement
Prevents accidental operations with Key Lock


(A) Operation Indicator LEDs
(B) Front Membrane Sheet Buttons
[Program Mode] MODE, Digit Select, Value Set, ENTER
[Measurement Mode] Span Shift, Zero Shift
Key Lock, etc.



Front Panel Blue / Pink Types [Optional]
*Design is subject to change


Mounting Hooks [Left/Right]
Easy tool-free attachment and removal

Versatile Usage Options

Portable Measurement


Carry the unit, PC/tablet, and cables for USB-powered* measurement. Carrying case BXS-1 (sold separately) is also available.
*For Load Cell / Pressure Meters ST(L), supply power via rear terminals, not the USB connector.



> BXS-1 Overview

Panel Integration


Compact 24x48 size contributes to space savings.


> 24x48 Dimensions

DIN Rail Mounting


One-touch mounting fixtures and models without displays are available.

BXF-DN2
DIN Rail Fixture (Sold separately)
2451 Type
Without Display
2431 Type
With Display
> BXF-DN2 Page > View 2451 & 2431 Details

Other CAN Converters Available

Load Cell to CAN >

Excitation 2.5 V / 5 V / 10 V, Bridge 120 Ω / 350 Ω

Strain Gauges Load Cells Pressure Sensors Accelerometers
Current to CAN >

Supports ±100 μA to ±10 A

Battery Charge Current Solenoid PWM Current Motor Clamp-on
Sensors
Voltage to CAN >

Supports ±10 mV to ±70 V

Pressure Sensors Displacement Sensors ECU Level Sensors
Resistance to CAN >

For Displacement & Resistance Output Sensors

Potentiometers Internal Resistance
Thermistor to CAN >

High-Precision Conversion via Proprietary Algorithm


NTC Thermistor
TC to CAN >

For Thermocouple Types K, J, R, E, T, B, N, S

RTD to CAN >

Supports RTD Pt100 Sensors

Angle / Position / Displacement to CAN >

For Length, Angle, Displacement, Flow Rate, etc.

Gear Sensors Stroke
Sensors
Rotary
Encoders
Linear
Encoders
Torque (Freq. Pulse Input) to CAN >

For Torque & Fuel Mix Ratio Sensors

Torque Sensors Flex-Fuel Sensors
CAN to Voltage Converters >

Convert CAN to Voltage or Alarm Signals

Automotive Construction
Machinery
Agricultural
Machinery
Office Equipment, etc.

Custom Modifications Available [Please Contact Us]

View List >
Flexible Choice of Measurement Types & Channels
Convenient, Easy & Low Cost
Functional Modifications: Power, Output Voltage, Communication Specs, etc.
Available from 1 Unit
Calibration Available as Embedded Unit
Calibration Certificates & Traceability Charts Available

Enclosure / Box Mounting

 Read More > 

Multi-CH with Display

 Read More > 

Multi-CH Radiation Thermometer CAN Output

 Read More > 

With SD Logger

 Read More > 

Rack Mounting

 Read More > 

Handheld Type

 Read More > 

Selection of Connectors, Display Presence, Power Supply, etc.

Connectors
Terminal Block
For Thermocouple
Banana Plug
BNC
       
LAN
USB-C
D-sub
HDMI
       
Display Options

LCD Monitor

Without Display

External Monitor Output

Free monitor display software
*Monitor not included
Power Supply
AC
DC
> Inquiry Form