計測器メーカーのココリサーチ
Products
Applications
Technical Info.
Support
Company
Contact Us
Japanese
PAGE
TOP

Signal Converters / Conditioners / Transducers / Transmitters Lineup

For signal branching
For isolation (isolators)
For noise suppression
For alarm outputs
For distributors, etc.
Input Type
Pulse Frequency
Temperature
Current/Voltage
Load cell, pressure, strain gauge
Resistor/Potentiometer
CAN
Multi-CH
Customization

Series features
■Compatible with 35mm DIN rails (Attachment included)
*DIN rails are not included.

Signal Converter Selection Guide

Signal Converter with Display Selection Guide
LD / LR Series CPx series

*Appearance varies depending on the model.
■For noise suppression from measurement lines
■For signal branching in control panel
EX2451 series EX2431 series
■Output: 16-bit analog, CAN, RS-485, alarm ■USB-C equipped
■Configuration and CSV logging software free of charge
■As an input module for PLCs ■Isolation support
Input
Isolated/
Non-isolated
Output

Line Driver
Number of input/output points: 1-3

Logic
Open collector(NPN/PNP)

[Power supply output for sensor]
LR Series
Noise suppression, long-distance wiring, signal branching
 

Logic
Number of input/output points: 1-3

Non-isolated

Line Driver
[Power supply output for sensor]
LD Series
Noise suppression, long-distance wiring, signal branching
 
Logic Zero cross

Isolated

Logic
[Power supply output for sensor]
Pulse Isolator CPI-DN1
Noise suppression, signal branching, etc.
 
Logic Zero cross

Isolation
Frequency
divider

Logic Frequency divider
[Power supply output for sensor]
Isolated frequency divider CPD-DN1
Pulse rate conversion, pulse smoothing, etc.
 
Logic Zero cross

Isolation
Multiplication

Logic 2 multiplier
Isolated 2-multiplier CPM-DN1
Improved measurement response and pulse resolution<
 

Zero cross

Logic
Open collector(NPN)
Zero-cross interface
CPA-DN1

Noise suppression, stable detection of low speed, etc.
 
Speed/Frequency
General-purpose, Line driver, A/B phase
 

Isolated/
Non-isolated
16bit analog
CAN
Alarm
RS-485
USB

[Power supply output for sensor]

SPD-2451 0.1ms/1ms update
SPDL-2451 40ms update
Proprietary PeriomaticTM
Without display

SPD-2431 0.1ms/1ms update
SPDL-2431 40ms update
Proprietary PeriomaticTM
With display

Frequency deviation/torque
General-purpose, Line driver, A/B phase
 

Isolated/
Non-isolated
16bit analog
CAN
Alarm
RS-485
US

[Power supply output for sensor]

TQ-2451  0.1ms/1ms update
TQL-2451 40ms update
Proprietary PeriomaticTM
Without display

TQ-2431  0.1ms/1ms update
TQL-2431 40ms update
Proprietary PeriomaticTM
With display

 Temperature input List 
 TC input List 
 RTD input List 
Thermistor input List
Input Output
Thermocouple
K,J,T,B,R,E,N,S type
16bit analog [voltage/current]
CAN
Alarm
RS-485
USB

HT-2451  2ms update
HTL-2451 40ms update
Without display

HT-2431  2ms update
HTL-2431 40ms update
With display

RTD
Resistance thermometer
Pt100 3-wire
16bit analog [voltage/current]
CAN
Alarm
RS-485
USB

HT-2451R  1ms update
HTL-2451R 40ms update
Resistance value check function
Without display

HT-2431R  1ms update
HTL-2431R 40ms update
Resistance value check function
With display

Thermistor
NTC Thermistors
16bit analog [voltage/current]
CAN
Alarm
RS-485
USB

HT-2451T  1ms update
HTL-2451T 40ms update
High-precision conversion by
proprietary calculation
Without display

HT-2431T  1ms update
HTL-2431T 40ms update
High-precision conversion by
proprietary calculation
With display

Current input list
Voltage input list
Distributors list
DC Current Output
±10A ±5A ±2A ±1A
±200mA ±100mA ±20mA ±10mA
±2mA ±1mA ±200μA ±100μA
4(0)-20mA* *:Process signal  
16bit analog [voltage/current]
CAN
Alarm
RS-485
USB

PSA-2451  1ms update
PSAL-2451 40ms update
Oversampling 250kHz
Without display
Sensor Power Supply Output Option

PSA-2431  1ms update
PSAL-2431 40ms update
Oversampling 250kHz
With display
Sensor Power Supply Output Option

DC Voltage Output
±70V ±30V ±20V ±10V
±5V ±2V ±1V ±200mV
±100mV ±20mV ±10mV 1(0)-5V*
0-10V* *:Process signal  
16bit analog [voltage/current]
CAN
Alarm
RS-485
USB

PSV-2451  1ms update
PSVL-2451 40ms update
Oversampling 250kHz
Without display
Sensor Power Supply Output Option

PSV-2431  1ms update
PSVL-2431 40ms update
Oversampling 250kHz
With display
Sensor Power Supply Output Option

Load cell input list
Input Output
Load cell 16bit analog [voltage/current]
CAN
Alarm
RS-485
USB

ST-2451  1ms update
STL-2451 40ms update
Without display
Sensor-induced voltage: 2.5V/5V/10V/Other

ST-2431  1ms update
STL-2431 40ms update
With display
Sensor-induced voltage: 2.5V/5V/10V/Other

Resistor / Potentiometer input list
Input Output
Resistor
Potentiometers and Displacement sensor, etc.
16bit analog [voltage/current]
CAN
Alarm
RS-485
USB

RR-2451  1ms update
RRL-2451 40ms update
Without display

RR-2431  1ms update
RRL-2431 40ms update
With display

CAN input list
Input Output
CAN2.0 16bit analog [voltage/current]
Alarm
USB

CAN-2451  1ms update
CANL-2451 40ms update
Without display

CAN-2431  1ms update
CANL-2431 40ms update
With display

Input
15CH CAN2.0
Output
15CH Contact (Alarm) Signal
(NPN Open collector)

CAN-1801  Within 100 ms update
Compare and evaluate each channel of CAN15CH, then output contact signal 15CH
A single CAN ID enables processing of 15 CHs of data.

Multi-channel input Output
CAN2.0 16bit analog [voltage/current]
Alarm
USB

Multi-CH CAN Converter
Freely select number of CHs, connectors, power supply, monitor, etc.
[E.g. shown in left diagram] CAN to Voltage Converter, 20 CHs

Pulse
Temperature
Current
Voltage
Resistance
Load cell
16bit analog [voltage/current]
CAN
Alarm
RS-485
Ethernet
HDMI
USB
Multi-CH Converter
Freely select measurement types, number of CHs, connectors, power supply, etc.
[E.g. shown in left diagram] 4 thermocouple channels + 2 voltage channels with display unit
Customization list

Boxed type
Easy to use and low cost

With SD logger
Logging data storage

Radiation Temp. Transducer Multi-CH
Non-contact Multi-CH Temp. Measurement

Multi-CH CAN output
20CH, with display

Rack Mounted
DIN rail mounting available


Handy type
with display

 > Contuct us