For real-time voltage measurement and feedback control |
±70V | ±20V | ±10V | ±5V | ±2V | ±1V | |
±200mV | ±100mV | ±20mV | ±10mV | 1(0)-5V* | 0-10V* | *Process signal support |
Please contact us for other ranges |
Measurements
For various applications
CAN output [Option]
|
16bit analog output [Option] Alarm output [Option] 1 to 4points [Depends on model] USB Type-C [standard feature] |
Front operation. Setting and measuring
(A) Operation indicator LED (B) Front sheet button - [In program mode] MODE, digit selection, numeric setting, ENTER - [In measurement mode] Span shift, Zero shift - Key lock, etc. |
Blue/pink type [Option] *Designs are subject to change. |
CSV logging | Compare and match set value lists | PC save and copy of set values | Prevention of misoperation | Quickly set up multiple units | ||||
Time-specified logging, such as 600 seconds, is also available. Custom logger software is also available. | Multiple lists of set values can be compared and collated. | It prevents errors in note-taking and manual entry, and reduces management effort and costs. | Settings and confirmations can be made on the PC screen, preventing misoperation of the main unit's buttons. | Even multiple units can be easily configured by simply writing the configuration data. |
USB Type-C connector standard | Setup unit without LINKSHIP or PC required: Program Loader PL-5A [sold separately] |
PL-5A Product Page *Setting only / data logging and power supply not available |
ECU |
Voltage | → | DC Voltmeter |
Measurement/ setting |
Measurement Management Software LINKSHIP |
||
Current | → | DC Ammeter |
Analog output →→→ |
Oscilloscopes Data Loggers |
|||
Temperature | → | Thermocouple Meter Resistance Thermometers |
CAN →→→ |
PLC |
Specifications
Name Model Measuring method |
DC Ammeter PSV-4801 ΔΣ integral method |
||||
Input | Number of input points |
1 point | |||
Measuring range | Model type ±70V ±20V ±10V ±5V ±2V ±1V ±200mV ±100mV ±20mV ±10mV 1-5V [Process signal support] 0-10V [Process signal support] |
||||
Measurement accuracy Oversampling Input low-pass filter Input connector Sensor Power supply - output [Option] |
±0.1%FS +1digit 250kHz fixed Cut-off frequency 1kHz Terminal block 7.62mm pitch M3 free terminal screw [H] DC +12V±5% 60mA max / [L] DC +5V±5% 150mA max |
||||
Calculation | Moving Average Number Low cut function Control input [Functions] [ON logic] [Operation Method] [Data communication] [Response time] [Backup] Setting value memory |
1 to 99 Judged to be 0 at voltage values below the set value 2 or 4 points [Varies depending on model.] Functions and ON logic can be set for each CTL for external control. Hold (current/max./min. value, max. fluctuation range), zero/span shift, zero/span set Normally open /normally closed ON when control input (CTL*) pin (ON logic) is shorted (open) to GND; setting is reflected when open (shorted). Command control is possible via communication (USB, CAN, RS-485) Commands set via communication cannot be released by terminal input. Reset execution is always required. Response time can be set: 1 to 1999 ms Possible to back up values during shift and set operations. (values can be retained even when power is turned off) Nonvolatile memory (EEPROM) |
|||
Display | Display Color Indicator (Numerical Display) Decimal point position Display update time Display moving average times Display accuracy Indicator (4 round LEDs) |
[Standard] PSV-4801 Red LED / [Option] PSV-4801-G Green LED 6-digit, 7-segment LED Character height 14.2mm / Display range:-199999 to 999999 Polarity indication: Reverse rotation -Lighted / Over indication: OL / Zero indication: Leading zero suppress Semi-fixed Decimal point position is set in program mode. [0] ******, [1] *****.* to [4] **.**** 0.3 sec (settable from 0.1 to 9.9 sec) 1 time (settable from 1 to 9 times) 5ppm ± 1 digit [IN ] Not used [RUN ] Lights up when function setting is ON (function setting is available) [COMP1] Lights up when comparator[Alarm] output 1 is ON (option) [COMP2] Lights up when comparator[Alarm] output 2 is ON (option) |
|||
USB communication |
Communication specification Communication function Output update time |
USB2.0 (Serial port communication by USB virtual COM 230.4kbps) Writing/reading of set values/continuous output of measured values 1 to 9999ms, settable in 1ms increments |
|||
General Information |
Operating temp./humidity Power supply voltage Power consumption Isolation Withstand voltage Weight |
-10°C to +50°C / 35 to 85%RH (non-condensing) PSV-4801-AF: AC100-240V (Maximum rated AC85-264V) 50/60Hz PSV-4801-DF: 12-30V DC with reverse connection protection 3W or less Power Supply/ Voltage input /Other Input/output Between each terminal of the above isolations: 500V DC between each terminal for 1 minute. Approx. 340g |
|||
CAN Option | Communication specifications Communication function Setting item Output update time |
CAN2.0B 10 k / 20 k / 50 k / 100 k / 250 k / 500 k / 1M bps, [Format] INTEL/MOTOROLA, [Frame] 11bit/29bit Writing/reading of set values/continuous output of measured values CAN transmit ID, CAN receive ID 1 to 9999 ms (settable in 1 ms increments) |
|||
RS-485 communication option |
Number of connected units Communication format Communication method Communication standard Communication speed Data format Communication code Communication function |
32 units (max.) 2-wire multi-drop serial communication Asynchronous RS-485 9,600 /19,200 /38,400bps Set in program mode Start bit: 1 bit / Stop bit: 1 bit / Data length: 8 bits / Parity bit: None ASCII Writing/reading set values/measurement value output (response to request command) Modbus RTU support is available upon request. |
|||
Analog output option |
Output signals D/A conversion method Output resolution Load resistance Output accuracy Temperature fluctuation Output scaling Output update time Response time after calculation |
[E1] 0 to 10 V, [E5] 0 to 5 V, [R1] ±10 V, [R5] ±5 V, [I1] 4 to 20 mA [Select a model] DAC conversion method 16bit (50,000 or more) [Voltage output] 4.7kΩ or more / [Current output] 300Ω or less [Voltage output] ±0.1% of FS @ 23°C / [Current output] ±0.1% of FS @ 23°C ±200ppm/℃ or less Arbitrary scaling is possible by full scale and zero scale settings 1 to 9999ms settable in 1ms increments 1 ms or less, 0 - 90% response. |
|||
Alarm [Comparator] output option |
Setting method Number of outputs Output form Output load voltage Output logic Update time |
Set in program mode 2 points Isolated non-contact output (photo-MOS relay) No polarity. When comparator operating condition is ON, resistance between COMP and COM: 50 Ω or less Peak AC/DC280V 100mA (resistive load) / ON resistance 50Ω or less Comparison is made with polarity (0 is greater than minus) [Over] ON when set value or more / [Under] ON when set value or less/ [Within range] ON within the set value, OFF outside the range [Out of range] ON outside the set value, OFF inside the range Depends on analog output update time setting. Response time 1ms (max) |