- Mechanisms using hydraulic cylinders are used in various applications such as vehicles and production equipment.
High-precision display and data output of stroke volume is required for automation, labor saving, visualization, improvement of work accuracy, time saving, and other purposes.
- High-resolution flow sensor converts into a pulse signal that is resistant to long-distance transmission noise, even over long distances to the control panel.
Voltage output is possible in a control panel with low noise, enabling high-precision measurement.
- If you purchase a flow sensor and counter as a set, COCORESEARCH will prepare a setting value table, change the setting values to match the usage conditions, and ship the product from the factory.
Measurement image::Piston travel in mm(flow sensor: VC0.2 made by KRACHT)
Voltage output Current output etc. |
1) |
In case of piston diameter A=100mm and rod diameter B=40mm The pressure receiving area (shaded area) C = 502 x π - 202 x π = 6597.3 mm2 |
2) |
When the piston moves 1mm, the amount of oil returned from the cylinder D = Cx1= 6597.3x1 = 6597.3mm3. |
3) | Since flow rate E = 245mm3/Pulse per tooth (pulse) of flow sensor VC0.2 D / E = 6597.3 / 245 = 26.928 Pulse when the piston moves 1mm. |
4) | The piston travel per pulse is E/C = 245/6597.3 = 0.0371364 mm. |
5) | Enter and set the value of item 4) to the above counter with item 1 (mantissa part): 371364 and item 2 (exponent part): 7. |
Damper for vehicles | Welding, polishing, and crimping machines | Injection molding machines | Hydraulic jacks and gates | Construction and agricultural machinery | Thickness control for foil manufacturing equipment, rolling machines, and laminators | Tension control for printing and winding machines |
What we can do with measurement
- High-resolution flow sensors and our unique Periomatic™ calculation method allow detailed monitoring of cylinder behavior from very low flow rates.
- High-precision measurement even when the measurement target and control panel are far apart, thanks to noise-resistant pulse signals that can be transmitted over long distances.
- Analog and digital outputs with fast update times display and measure cylinder movement.
- CAN communication automatically outputs measurement data at each update time, reducing program development costs (depending on model).
Measurement data other than CAN communication is acquired by command response method
Selection Points
Flow sensor
- Capable of displaying and measuring from very low flow rates (XFS series)
- Pulse output is resistant to noise during long-distance transmission. 2.
Measuring instruments
- Analog output for 0.5ms (CNT-49), 0.1ms (SPD series), 1ms (PFC-4921), 40ms (SPDL series) update
- CAN communication with 1ms (SPD series), 40ms (SPDL series) update
- Periomatic™ calculation method for high accuracy and fast response even at ultra-low speeds
- Periomatic™ calculation method, high accuracy and high speed response even at very low speeds.
- Factory setting of the instrument and creation of a set value table are available when ordered as a set with a flow sensor.
Product | Points | Overviews | |
---|---|---|---|
XFS Series |
Compact, lightweight Highly accurate Suitable for various liquids Backflow compensation type available |
- Compact and lightweight gear type positive displacement flow sensor - Low pressure drop due to special elliptical gear - Highly accurate measurement from very low to high flow ranges - Compatible with a wide range of liquids |
|
CNT-4921/4931 Product page |
Analog output RS-485 RS-232C BCD output Alarm output Quadruplicated measurement Scaling function Reset input Count value backup LINKSHIP compatible |
- 16bit analog output with 0.5ms update - Various options such as RS-232C/RS-485/BCD output - Up to 4 alarm outputs can be mounted - 46x98 size panel meter with scaling function - LINKSHIP" compatible, which can also be set via PC |
|
SPD-4801 |
USB RS-485 Modbus CAN Analog output Alarm output Zero shift Span shift Stop/start totalization LINKSHIP compatible |
- 48x96 size for flowmeter, frequency meter, tachometer, speed meter, etc. - Simultaneous 16-bit analog output (0.1 ms) and CAN output (1 ms) - LINKSHIP" compatible for logging/setting via USB |
|
SPD-2401 |
USB RS-485 Modbus CAN Analog output Alarm output Zero shift Span shift Stop/start totalization LINKSHIP compatible |
- 24x48 size for flowmeter, frequency meter, tachometer, speed meter, etc. - Simultaneous 16-bit analog output (0.1 ms) and CAN output (1 ms) - Supports "LINKSHIP" for power supply, logging, and settings via USB - Panel mounting type: SPD-2401 (with display) - DIN rail mounting type: SPD-2451 (without display), SPD-2431 (with display) |
|
SPDL-2401 |
USB RS-485 Modbus CAN Analog output Alarm output Zero shift Span shift Stop/start totalization LINKSHIP compatible |
- 24x48 size for flowmeter, frequency meter, tachometer, speed meter, etc. - Simultaneous 16-bit analog output (40 ms) and CAN output (40 ms) - Supports "LINKSHIP" for power supply, logging, and settings via USB - Panel mounting type: SPDL-2401 (with display) - DIN rail mounting type: SPDL-2451 (without display), SPDL-2431 (with display) |
|
PFC-4921 |
Reset input Start input Stop input Analog output Quadruplicated measurement Scaling function Totalized flow backup Alarm output LINKSHIP compatible |
- Simultaneous measurement of instantaneous flowrate (L/min, etc.) and totalized flowrate (mL, etc.) - Quadruplicated measurement function - 16bit analog output with fastest 1ms update - Up to 4 alarm outputs - 46x98 size panel meter with scaling function - "LINKSHIP" compatible for PC setting |
|
SPD-HD |
USB RS-485 Modbus CAN Analog output Alarm output Zero shift Span shift Stop/start totalization LINKSHIP compatible |
- Speed/totalizer [switchable] for flowmeter, frequency meter, tachometer, speed meter, etc. - Handy type that can be used on site for shipping/performance inspection, equipment inspection, operation check, etc. - Simultaneous 16-bit analog output (0.1 ms) and CAN output (1 ms) - Supports 2-way power supply (alkaline battery/AC adapter) - Supports "LINKSHIP" for logging/configuration via USB - Selectable connectors such as unique retractable BNC and terminal block |