The following inquiries are increasing
An increasing demand for high-speed, high-accuracy detection and measurement of weak currents (such as instrumentation signals of equipment and ignition pulses of engines).
The combination of a high-precision clamp-type sensor and our measuring instruments makes it possible to detect and measure currents easily, accurately, and with a fast response time.
Measurement image
![]() ENGINE, MOTOR |
![]() Ignition Pulse of Direct Ignition |
![]() ![]() Panel meter Signal converter Distributer |
→ Voltage output Current output Alarm output CAN RS-485 etc. |
![]() Ignition current between distributor and plug, coil and battery |
|
||
| POINT! | ||
| Variable trigger level function | Adjustment to match the ignition signal | |
| Low-pass filter | Measure without being affected by noise | |
*Confirmation of operation for each application is required for actual use. Please contact us for details.
Other examples of current measurement
![]() |
Detection of field currents in motors | ![]() |
Aging detection of solenoid-based electrical equipment | ![]() |
Detection of leakage current and instrumentation signals in equipment |
Selection Points
Clamp type sensor
- Non-contact clamp type: Easy sensor installation and no modification to the measurement target (e.g., cables, etc.) is required.
- Compact and lightweight: Easy installation in confined spaces such as engine rooms and inside panels.
- High-precision sensing of weak direct current
Measuring instrument
- Variable trigger level function: Can be adjusted to match the ignition signal (SPD/SPDL)
- Low-pass filter: Enables measurement without being affected by noise (SPD/SPDL)
- Analog output for 0.5ms (TDP-49), 0.1ms (SPD), 1ms (PSV), 40ms (SPDL/PSVL) updates
- CAN communication with 1ms (SPD/PSV) and 40ms (SPDL/PSVL) updates
- Periomaticâ„¢ calculation method (TDP, SPD, SPDL) for high accuracy and fast response even at very low speeds
- Factory setting of measuring instruments and creation of setting value table are also available
Products
| Products | Points | Overviews | |
|---|---|---|---|
|
TDP-4921/TDP-4931 |
RS-485 RS-232C Analog output Alarm output BCD output LINKSHIP support |
- 16bit analog output with 0.5ms update |
|
SPD-4801 |
RS-485 Modbus CAN Analog output Alarm output Zero shift Span shift Count Stop/Start LINKSHIP support |
- 48x96 size speed/totalizer [switchable] for frequency meter, tachometer, flowmeter, speed meter, totalizer, etc. |
|
SPD-2401
SPDL-2401 |
RS-485 Modbus CAN Analog output Alarm output Zero shift Span shift Count Stop/Start LINKSHIP support |
- 24x48 size speed/totalizer [switchable] for frequency meter, tachometer, flowmeter, speed meter, totalizer, etc. |
|
SPD-HD |
RS-485 Modbus CAN Analog output Alarm output Zero shift Span shift Count Stop/Start LINKSHIP support |
- Speed/totalizer [switchable] for frequency meter, tachometer, flowmeter, speed meter, totalizer, etc. |
|
PSV-2401
PSVL-2401 |
RS-485 Modbus CAN Analog output Alarm output LINKSHIP support |
- 24x48 size DC voltmeter with 12 measurement ranges to choose from. Process signal model also available. |
Picsor series of clamp-type sensors (weak current, pulse, etc.) that combine high accuracy and ease of use
We also support the selection of sensors and measuring instruments that meet your facility specifications. Please feel free to contact us.