DC Voltmeter PSVL-24
Digital panel meter, signal converter, indicating alarm meter, distributor

Option
Dimensions
Applications
Software

For real-time voltage measurement and feedback control

Average current per output update time is measured with a ΣΔAD converter with oversampling of approximately 250 kHz. Rates can be set as desired.

Inputs
Voltage signals
Pressure sensor
Displacement sensor

 
ECU
Level sensor
Power supply for sensor
・12V/5V/others
 
Calculation
・Oversampling 250kHz
・Moving average Max. 99
・Low cut
・HOLD [Current value/Max. value/Min. value/Max. variation range]
Zero/Span shift, Zero/Span set
PSVL-24 series
Power supply
・7 to 30V DC
・USB power 5V
Setting
・LINKSHIP software
・Setting unit PL-5A
   
Output
・16bit analog ・Alarm
・CAN ・RS-485 ・Modbus ・USB
 
PC

 
PLC
 
Logger
Oscilloscope
 
Indicator lamps
Various applications
DC Voltage
Measurement
Pressure
Measurement
Displacement
measurement
Voltage to CAN
conversion
Internal voltage
measurement

13 models by input range
Input resolution 10.4ns

Please select the input range when ordering. Please consult us for ranges other than those listed below.
±70V
±30V
±20V
±10V
±5V
±2V
±1V
±200mV
±100mV
±20mV
±10mV
1(0)-5V*
0-10V*
*Process signal support

Body Type

PSVL-2401

Front USB


PSVL-2411

Rear USB, Front waterproof gasket included


PSVL-2431

DIN rail mounting, with indicator


PSVL-2451

DIN rail mounting, no indicator


Customization [Minimum of 1 unit: Please consult with us]

 >View more 

■Select and combine only what you need
■Convenient, easy, and low cost
■Functional change : power supply, output voltage, communication specifications, etc.
■Calibration as an embedded product is available
■Calibration documents and traceability charts can be issued

Compact multi-CH
Flexible number of CHs

Boxed type
Easy to use and low cost

With SD logger
Logging data storage

Multi-CH CAN output
20CH, with display

Rack Mounted, Control Box

HDMI output, multi-CH

Output 40ms update

 See 1ms type> 

CAN [Option]]

3-wire wiring greatly reduces wiring compared to BCD
Powerful error detection system for improved noise immunity and safety

SAE J1939 [DLC 8 bytes or less] Customization experience available
Please contact us for other customizations.

RS-485 [Option]

16bit analog [Option]
Resolution 50,000 or more/Full scale and zero scale settings, output zero adjustment


Alarm [Option] 1 to 4points [Depends on model]


USB Type-C [Standard feature] Data logging, setting


Reasonable and easy-to-use 1CH type

 See High-spec. version > 
PSVL-2401
17,600 yen and up*
Display only, Equipped with USB communication
PSVL-2451
19,300 yen and up*
DIN rail mounting, no display, Comparator output 2 points
*Prices as of February 2024, in Japan. Tax not included
 See options and price list> 

Smart configuration and logging

Setting management, report printing, and CSV logging with dedicated software LINKSHIP [free of charge]

 LINKSHIP Page > 

CSV logging



Time-specific logging available. Custom logger software is available.

Compare set value lists



Multiple lists of set values can be compared and collated.

Save and copy of set



Prevents errors in handwriting and typing, and reduces management time and costs.

Prevention of misoperation



Settings and confirmations can be made on the PC screen, preventing misoperation of the main unit's buttons.

Quickly set up multiple units



Even multiple units can be easily configured by simply writing the configuration data.

USB Type-C connector standard:For setting / logging / power supply


Setup unit without LINKSHIP or PC required [Sold separately]



>PL-5A Product Page
*Setting only / data logging and power supply not available

Easy wiring and installation For on-site usability

Detachable Plug Connectors
Simply connect the wires to the connector and plug it in by hand.

Detachable Plug Connectors
Spring lock type [Standard]


Detachable Plug Connectors
M2 screw type [Option]

Fixed Connector
Non-detachable [Customize]


Mounting hooks
Fixing the main body


*Not included in 2431 and 2451 types

Various ways to use

Carry and measure

Carry PC, instrument, and cable, and measure with USB power supply. Storage case BXS-1 is also available.



>BXS-1 Overview

Built in panel

24x48 size contributes to downsizing


>PSVL-24 Dimensions

DIN rail mounting

One-touch fixture and display-less type

BXF-DN2
DIN rail attachment [sold separately]
PSVL-2451
Display-less type
PSVL-2431
With display type
>BXF-DN2 page

Power supply 7 to 30V DC, and 5V USB power supply

Isolation Electrical isolation between power supply/voltage input/other inputs and outputs

Application

 Applications list> 


Voltage, Current Measurement for ECU Development


Voltage to CAN conversion


Measure and monitor valve opening (angle)


Wind Tunnel Testing / vehicles, motorcycles, architectural and civil engineering structures, etc.

 Model List, Options and Prices > 

  Name
Model
Measuring method
DC Voltmeter
PSVL-2401
ΔΣ integral method
Input  Number of input points
1 point
  Measuring range Model type
±70V
±30V
±20V
±10V
±5V
±2V
±1V
±200mV
±100mV
±20mV
±10mV
1-5V [Process signal support]
0-10V [Process signal support]
   
  Measurement accuracy
Sampling speed
Input low-pass filter
Input connector
Sensor Power supply -
output [Option]
±0.1%FS +1digit
2000 times/second
Cut-off frequency 1kHz
Spring lock plug connector / [J04 option] M2 screw type plug connector
[H] DC +12V±5% 60mA max / [L] DC +5V±5% 150mA max
*When USB power is supplied, power for the sensor is not output.
Calculation Moving Average Number
Low cut function
Control input

 [Functions]
 [ON logic]
 [Operation Method]
 [Data communication]

 [Response time]
 [Backup]
Setting value memory
1 to 99
Judged to be 0 at voltage values below the set value
2 or 4 points [Varies depending on model.]
Functions and ON logic can be set for each CTL for external control.
Hold (current/max./min. value, max. fluctuation range), zero/span shift, zero/span set
Normally open /normally closed
ON when control input (CTL*) pin (ON logic) is shorted (open) to GND; setting is reflected when open (shorted).
Command control is possible via communication (USB, CAN, RS-485)
Commands set via communication cannot be released by terminal input. Reset execution is always required.
Response time can be set: 1 to 1999 ms
Possible to back up values during shift and set operations. (values can be retained even when power is turned off)
Nonvolatile memory (EEPROM)
Display Display Color
Indicator (Numerical Display)

Decimal point position
Display update time
Display moving average times
Indicator
[Standard] PSVL-2401 Red LED
5-digit, 7-segment LED Character height 9mm / Display range:-19999 to 99999
Polarity indication: Reverse rotation -Lighted / Over indication: OL / Zero indication: Leading zero suppress
Semi-fixed Decimal point position is set in program mode. [0] *****,  [1] ****.* to [4] *.****
0.3 sec (settable from 0.1 to 9.9 sec)
1 time (settable from 1 to 9 times)  
LED 1 point (selected from power/ control input)
USB
communication
Communication specification
Communication function
Output update time
USB2.0 (Serial port communication by USB virtual COM 230.4kbps)
Writing/reading of set values/continuous output of measured values
40 to 9999ms, settable in 1ms increments
General
Information
Operating temp./humidity
Power supply voltage
Power consumption
Isolation
Withstand voltage
Weight
-10°C to +50°C / 35 to 85%RH (non-condensing)
7 to 30V DC with reverse connection protection. Power supply from USB host: 5V
3W or less
Power Supply/ Voltage input /Other Input/output
Between each terminal of the above isolations: 500V DC between each terminal for 1 minute.
Approx. 60g
CAN Option Communication specifications
Communication function
Setting item
Output update time
CAN2.0B 10 k / 20 k / 50 k / 100 k / 250 k / 500 k / 1M bps, [Format] INTEL/MOTOROLA, [Frame] 11bit/29bit
Writing/reading of set values/continuous output of measured values
CAN transmit ID, CAN receive ID
40 to 9999 ms (settable in 1 ms increments)
RS-485
communication
option
Number of connected units
Communication format
Communication method
Communication standard
Communication speed
Data format
Communication code
Communication function

32 units (max.)
2-wire multi-drop serial communication
Asynchronous
RS-485
9,600 /19,200 /38,400bps Set in program mode
Start bit: 1 bit / Stop bit: 1 bit / Data length: 8 bits / Parity bit: None
ASCII
Writing/reading set values/measurement value output (response to request command)
Modbus RTU support is available upon request.
Analog
output option
Output signals
D/A conversion method
Output resolution
Load resistance
Output accuracy
Temperature fluctuation
Output scaling
Output update time
[E1] 0 to 10 V, [E5] 0 to 5 V, [R1] ±10 V, [R5] ±5 V, [I1] 4 to 20 mA    [Select a model]
DAC conversion method
16bit (50,000 or more)
[Voltage output] 4.7kΩ or more / [Current output] 300Ω or less
[Voltage output] ±0.1% of FS @ 23°C / [Current output] ±0.1% of FS @ 23°C
±200ppm/℃ or less
Arbitrary scaling is possible by full scale and zero scale settings
40 to 9999ms settable in 1ms increments
Alarm
[Comparator]
output option
Setting method
Number of outputs
Output form

Output load voltage
Output logic



Update time
Set in program mode
2 points
Isolated non-contact output (photo-MOS relay) No polarity.
When comparator operating condition is ON, resistance between COMP and COM: 50 Ω or less

Peak AC/DC280V 100mA (resistive load) / ON resistance 50Ω or less
Comparison is made with polarity (0 is greater than minus)
[Over] ON when set value or more / [Under] ON when set value or less/
[Within range] ON within the set value, OFF outside the range
[Out of range] ON outside the set value, OFF inside the range

Depends on analog output update time setting. Response time 1ms (max)

Related Products

All products> Voltmeter lists>

Other measurements

 View more > 
CAN analog conversion DC current DC voltage
Thermocouple [temp.] Thermistor [temp.] RTD [temp.]
Speed/Count Frequency deviation/torque Resistance

CAN, 16bit analog, Alarm, RS-485, Modbus

 Various Outputs

Smart configuration / Prevents unintentional operation

 Software LINKSHIP

USB Type-C standard equipment

 For data logging, setting

Built in box, multi-CH, and function changes, etc

 Customization


EX48


EX(L)24