| Setting range |
Measurement range |
Open circuit voltage |
Measuring current |
Measurement error rate |
Minimum resolution |
| 150Ω | 0-160Ω | 3.3kV | 1000μA | ±0.02%FS | 0.01Ω |
| 1.5kΩ | 0-1.6kΩ | 0.1Ω | |||
| 10kΩ | 0-10kΩ | 100μA | 0.5Ω | ||
| 40kΩ | 0-40kΩ | 50μA | 1.5Ω |
| Input Potentiometer, internal resistance, etc. |
|
![]() ![]() |
![]() |
| Power supply for sensor ・12V/5V/others |
|
| Calculation ・Moving average Max. 99 ・HOLD [Current value/Max. value/Min. value/Max. variation range] ・Zero shift |
||
RR-24 series![]() ![]() ![]() |
![]() |
|
| Power supply ・7 to 60V DC ・USB power 5V |
Setting ・LINKSHIP software ・Setting unit PL-5A |
|
| Output | |||||||
PC, PLC, Logger, Oscilloscope, Indicators, etc.
![]() |
|||||||




| Resistance |
| Position |
| Angle |
| Resistor to CAN conversion |
| Internal Resistance measure |
| Position control |
| Steering angle control |
| >View more |
| See 40ms type> |
| SAE J1939 [DLC 8 bytes or less] Customization experience available Please contact us for other customizations. |
| See Low-cost version > |
| RR-2401 |
| 32,500 yen and up* |
| Display only, Equipped with USB communication |
| RR-2451 |
| 28,100 yen and up* |
| DIN rail mounting, no display |
| See options and price list> |
| LINKSHIP Page > |








Detachable Plug Connectors
Simply connect the wires to the connector and plug it in by hand.

Detachable Plug Connectors
Spring lock type [Standard]

Detachable Plug Connectors
M2 screw type [Option]

Fixed Connector
Non-detachable [Customize]

Mounting hooks
Fixing the main body

Carry PC, instrument, and cable, and measure with USB power supply. Storage case BXS-1 is also available.
![]() |
![]() ![]() >BXS-1 Overview |
One-touch fixture and display-less type
![]() |
![]() |
![]() |
| BXF-DN2 DIN rail attachment [sold separately] |
RR-2451 Display-less type |
RR-2431 With display type |
| >BXF-DN2 page |
| Applications list> |
| Model List, Options and Prices > |
| Name | Resistance meter | ||||||||||||||||||||||||||||||
| Model | RR-2401 / RR-2411 / RR-2431 / RR-2451 | ||||||||||||||||||||||||||||||
| Measuring method | ΔΣ integral method | ||||||||||||||||||||||||||||||
| Input | |||||||||||||||||||||||||||||||
| Number of input | 1 point | ||||||||||||||||||||||||||||||
| Measurement range 150Ω / 1.5kΩ / 10kΩ / 40kΩ [Ambient temperature 23°C]
|
|||||||||||||||||||||||||||||||
| Input connector | Plug type [Standard] Spring lock / [Option] M2 screw | ||||||||||||||||||||||||||||||
| Sensor Power supply - output [Option] |
[H] DC+12V±5% 60mA max/ [L] DC +5V±5% 150mA max | ||||||||||||||||||||||||||||||
| Calculation | |||||||||||||||||||||||||||||||
| Output moving average | 1 to 99 [Display moving average]1 to 9 | ||||||||||||||||||||||||||||||
| Control input | None or 1 point (depending on model) [D2] Option adds 2 points | ||||||||||||||||||||||||||||||
| [Settings] | Set functions per control input (CTL) for external control | ||||||||||||||||||||||||||||||
| [Functions] | Hold (current value, max value, min value, max fluctuation range), zero shift |
||||||||||||||||||||||||||||||
| [ON Logic] | Normally open, normally closed | ||||||||||||||||||||||||||||||
| [Operation] | Control Input (CTL*) Terminal (ON Logic): Short to GND (Open) for ON, Open (Short) for setting content to take effect |
||||||||||||||||||||||||||||||
| [Commnication] | Command control possible via communication (USB, CAN, RS-485) *Commands set via communication cannot be canceled by terminal input. Reset execution is always required |
||||||||||||||||||||||||||||||
| Setting Value Memory | Non-volatile Memory (EEPROM) | ||||||||||||||||||||||||||||||
| Display | |||||||||||||||||||||||||||||||
| Display Color | [Standard] RR-2401 Red LED [Option] RR-2401-G Green LED |
||||||||||||||||||||||||||||||
| Indicator [Numerical Display] | 5-digit, 7-segment LED Character height 9mm Display range:-19999 to 99999 Over indication: OL / Zero indication: Leading zero suppress |
||||||||||||||||||||||||||||||
| Decimal point position | Semi-fixed Set in program mode. [0] *****, [1] ****.* to [4] *.**** | ||||||||||||||||||||||||||||||
| Display update time | 0.3 sec [settable from 0.1 to 9.9 sec] | ||||||||||||||||||||||||||||||
| Display accuracy | 20ppm ± 1 digit | ||||||||||||||||||||||||||||||
| Display Moving Average | 1 to 9 | ||||||||||||||||||||||||||||||
| Indicator | LED 1 point [selected from power/ control input] | ||||||||||||||||||||||||||||||
| USB communication | |||||||||||||||||||||||||||||||
| Specification | USB2.0 [Serial port communication by USB virtual COM 230.4kbps] | ||||||||||||||||||||||||||||||
| Function | Writing/reading of set values/ Continuous output of measured values | ||||||||||||||||||||||||||||||
| Output update | 1 to 9999ms, settable in 1ms increments | ||||||||||||||||||||||||||||||
| General Information | |||||||||||||||||||||||||||||||
| Operating temp./humidity | -10°C to +50°C / 35 to 85%RH [non-condensing] | ||||||||||||||||||||||||||||||
| Power supply | 7 to 60V DC with reverse connection protection. Power supply from USB host: 5V | ||||||||||||||||||||||||||||||
| Power consumption | 3W or less | ||||||||||||||||||||||||||||||
| Isolation | Power supply / Resistance input / Other input/output | ||||||||||||||||||||||||||||||
| Withstand voltage | Between each terminal of the above isolation: DC 500V for 1 minute |
||||||||||||||||||||||||||||||
| Weight | Approx. 60g | ||||||||||||||||||||||||||||||
| CAN Option | |||||||||||||||||||||||||||||||
| Specifications | CAN2.0B 10 k / 20 k / 50 k / 100 k / 250 k / 500 k / 1M bps [Format] INTEL/MOTOROLA, [Frame] 11bit/29bit |
||||||||||||||||||||||||||||||
| Function | Writing/reading of set values/ Continuous output of measured values | ||||||||||||||||||||||||||||||
| Setting item | CAN transmit ID, CAN receive ID | ||||||||||||||||||||||||||||||
| Output update | 1ms to 9999ms settable in 1 ms increments | ||||||||||||||||||||||||||||||
| RS-485 communication option Modbus RTU support is available upon request. | |||||||||||||||||||||||||||||||
| Connected units | 32 units [max.] | ||||||||||||||||||||||||||||||
| Format | 2-wire multi-drop serial communication | ||||||||||||||||||||||||||||||
| Method | Asynchronous | ||||||||||||||||||||||||||||||
| Standard | RS-485 | ||||||||||||||||||||||||||||||
| Speed | 9600bps / 19200bps / 38400bps Set in program mode | ||||||||||||||||||||||||||||||
| Data format | Start bit: 1 bit / Stop bit: 1 bit / Data length: 8 bits / Parity bit: None | ||||||||||||||||||||||||||||||
| Code | ASCII | ||||||||||||||||||||||||||||||
| Function | Writing/reading set values/measurement value output [response to request command] | ||||||||||||||||||||||||||||||
| Analog output option | |||||||||||||||||||||||||||||||
| Output signals | [E1] 0 - 10V [E5] 0 - 5V [R1] ±10V [R5] ±5V [I1] 4 - 20mA [Select a model] | ||||||||||||||||||||||||||||||
| D/A conversion | DAC conversion method | ||||||||||||||||||||||||||||||
| Output resolution | 16bit [50,000 or more] | ||||||||||||||||||||||||||||||
| Load resistance | [Voltage output] 4.7kΩ or more / [Current output] 300Ω or less | ||||||||||||||||||||||||||||||
| Output accuracy | [Voltage output] ±0.1% of FS @ 23℃/ [Current output] ±0.1% of FS @ 23℃ | ||||||||||||||||||||||||||||||
| Temp. fluctuation | ±200ppm/℃ or less | ||||||||||||||||||||||||||||||
| Output scaling | Arbitrary scaling is possible by full scale and zero scale settings | ||||||||||||||||||||||||||||||
| Output update | 1 to 9999ms settable in 1ms increments | ||||||||||||||||||||||||||||||
| Response time after calculation | 1 ms or less, 0 - 90% response | ||||||||||||||||||||||||||||||
| Alarm [Comparator] output option | |||||||||||||||||||||||||||||||
| Setting method | Set in program mode | ||||||||||||||||||||||||||||||
| Number of outputs | 2 / 4 points [depends on the models] | ||||||||||||||||||||||||||||||
| Output form | Isolated non-contact output [photo-MOS relay] No polarity. When comparator operating condition is ON, resistance between COMP and COM 50 Ω or less |
||||||||||||||||||||||||||||||
| Output load voltage | Peak AC/DC280V 100mA [resistive load] / ON resistance 50Ω or less | ||||||||||||||||||||||||||||||
| Output logic | Comparison is made with polarity [0 is greater than minus]
|
||||||||||||||||||||||||||||||
| Update time | Depends on analog output update time setting. Response time 1ms [max.] | ||||||||||||||||||||||||||||||
| All products> | Resistance meters> |
| View List > |
| Load cell/Pressure/Strain | CAN to analog |
| DC current | DC voltage |
| Thermocouple meter | Thermistor meter |
| RTD meter | Resistance Meter |
| Speed/Count, Pulse Freq. | Torque/Freq.deviation |
Various Outputs
Software LINKSHIP
For data logging, setting
Customization