- Compatible with pulse output flow sensors, magnetic gear speed sensors, various encoders, linear gauges, etc.
- Ideal for length measurement, angle, displacement, totalized flow display, and signal conversion.
- Input: Single-phase 4MHz, A/B-phase 1MHz.
- 16-bit analog output with up to 1ms refresh rate, 4 comparator alarm outputs, RS-232C communication (Optional).
- Built-in sensor power supply / Supports LINKSHIP configuration software / 48×96 DIN size.
| No Range Switching Required | Reversible Measurement (For 2-phase input) |
Eliminates Reversible Count Errors Strong Performance at Low Speeds (A/B phase 4x multiplication) |

Rotary Encoders

Linear Scales

| Length Measurement |
| Angle |
| Displacement |
| Totalized Flow Display |
| Signal Conversion |
Totalized value per pulse and decimal point position can be configured arbitrarily.
| > What is PeriomaticTM? |



| Manual |
| Auto Count |
| Auto Reset |
Analog Output (1ms refresh)
Select from the 4 types below when ordering
| 0-10V |
| 0-5V (1-5V factory option available)* |
| ±10V |
| 0-20mA (4-20mA factory option available)* |
RS-232C Communication Cable (Sold separately / Length: 2.5m)

Settings can be configured using the 4-button pad located behind the front panel.
4-button pad behind the front panel
Displays instantaneous/totalized values, flow/time units, totalized elapsed time, etc.
Upper: 6 digits
Lower: 8 digits

Power Supply (Select when ordering)
| AC 100-240V |
| DC 9.6-30V |
Sensor Power Supply (Select when ordering)
| DC 12V |
| DC 5V |
| > View Examples |
| Flexible Measurement Types & Channels |
| Available from Single Unit Orders |
| Convenient, Easy, and Cost-effective |
| Calibratable as an Integrated System |
| Spec Modifications: Power, Output Voltage, Communication Specs, etc. |
| Calibration & Traceability Documents Issued |