Load cell meter ST-4801 Digital panel meter, signal converter, indicating alarm meter

Option/ Models
Dimesions
DXF data

Strain, pressure, displacement, load, weight, acceleration, etc.

CAN output
Versatile excitation voltage
Bridge Resistance 120Ω/350Ω

Rating can be set arbitrarily.
With versatile input ranges and hold/control functions, it can also be used as a scaling meter.

Input
Various voltage signals

Strain Gauges, Load Cells, Pressure, Displacement, Acceleration Sensors
Bridge Resistance 120Ω/350Ω

   
   
   
Sensor Power Supply
・2.5V/5V/10V/Other Voltages
 
Calculation/Signal Conversion
Zero/Span Shift ・ Zero/Span Set
Moving Average Max 99
HOLD [Current Value/Max Value/Min Value/Max Fluctuation Range]

ST-48 Series

Front

Rear
Power Supply
・DC12-30V
・AC100-240V
Settings
・Main Unit Buttons (Front Panel)
・Dedicated Software LINKSHIP
・External Setting Unit PL-5A
   
Output
CAN
RS-485
Modbus
USB
16-bit Analog
Alarm

PC・PLC・Logger・Oscilloscope・Indicator Light, etc.

  

 

Excitation voltage

2.5V
5V
10V
Other voltages
*Select model when ordering

Bridge Resistance

120Ω
350Ω

Customization - built into box, multi-CH, etc.

 >Read more 
- Flexible measurement types and number of CHs
- Convenient, easy, low cost
- Change functions Power supply, output voltage, communication specifications, etc.
- Support from a single unit
- Calibration as a built-in product is available.
- Calibration documents and traceability charts can be issued

Built into box

>Learn more

Backside

>Learn more

Multi CH in a box

>Learn more

Multi CH with display

>Learn more

HDMI output + display software

>Learn more

Rack Mounted

>Learn more

Output 1ms update

CAN [Option]]

3-wire wiring greatly reduces wiring compared to BCD
Powerful error detection system for improved noise immunity and safety

SAE J1939 [DLC 8 bytes or less] Customization experience available
Please contact us for other customizations.

RS-485, Ethernet [Option]

USB Type-C [Standard feature] Data logging, setting


16bit analog [Option]
Resolution 50,000 or more/Full scale and zero scale settings, output zero adjustment


Analog 2 Output [Option]
Example: 0-10V and 4-20mA output


Alarm [Option] 1 to 4points [Depends on model]


Easy setup, measurement and installation For ease of use on site

Front operation. Setting and measuring

(A) Operation indicator LED
(B) Front sheet button
- [In program mode] MODE, digit selection, numeric setting, ENTER
- [In measurement mode] Span shift, Zero shift
- Key lock: Prevents unintentional operation by field workers.


Blue/pink type[Option]]
*Designs are subject to change.
Mounting hooks [Left and right] For fixing the main unit

Smart configuration and logging Setting management, report printing, and CSV logging with dedicated software LINKSHIP [free of charge]

 > Download page 

CSV logging


Logging is possible by specifying the number of seconds. Custom logger software is available.

Compare and match set value lists


Multiple lists of set values can be compared and collated.

PC save and copy of set values


It prevents errors in note-taking and manual entry, and reduces management effort and costs.

Prevention of misoperation


Settings and confirmations can be made on the PC screen, preventing misoperation of the main unit's buttons.

Quickly set up multiple units



Even multiple units can be easily configured by simply writing the configuration data.

USB Type-C connector standard:For configuration and logging

Setup unit without LINKSHIP or PC required: [sold separately]


>PL-5A Product page
*Setting only / data logging and power supply not available

Power supply: 12 to 30VDC / 100 to 240VAC [Select a model]

Isolation Electrical isolation between power supply/voltage input/other inputs and outputs

Applications
For measurement and conversion applications involving strain, pressure, displacement, load, weight, acceleration, etc.

Crash Testing


Weighing, Defect Confirmation


Drift Loss and Actual Dispersion Volume


Tensile Force and Weight


Pressure in Tablet Presses, etc.


Pressing and Fitting in Press Machines


To Strain-Type Acceleration Sensors



Load Cell - CAN Conversion





CAN

Strain, Pressure, Temperature, CCCV Current/Voltage in Rechargeable Batteries >


Specifications

 Option/ Models> 
Tyoe ST-4801
Input
Input signal 1 point  Load cell signal
Bridge Resistance 120Ω / 350Ω excitation voltage:2.5V / 5.0V / 10.0V (±7%)
Measuring range ±5.1mV/V ADC resolution 60,000 or higher
Operable with specifications equivalent to the reference below:
・Span adjustment range: 1-4mV/V
・External shunt resistor adjustment range: Covers 40%-100% (factory default 80%)
・Zero adjustment range: -100% to 25% FS
Minimum Input Sensitivity 1μV/digit at Bridge voltage 5V
2μV/digit at Bridge voltage 10V
Measurement Accuracy ±(0.1% of FS + 1digit)@23℃ 35-85% *Sampling rate, 20 times/sec or less
Temperature Characteristics Zero: 0.02% FS/°C, Span: 0.02% FS/°C
Sampling Rate 1000 times/sec *ΔΣ AD conversion method
Sensor Power Supply Output 2.5V/5V/10V/Other voltage [Select Model]
   
Calculation
Measuring method ΔΣ integral method
Moving Average Number 1 to 99
Control input 2 or 4 points [Varies depending on model.]
Functions and ON logic can be set for each CTL for external control.
 [Functions] Hold (current/max./min. value, max. fluctuation range), zero/span shift, zero/span set
 [ON logic] Normally open /normally closed
 [Operation Method] ON when control input (CTL*) pin (ON logic) is shorted (open) to GND; setting is reflected when open (shorted).
 [Data communication] Command control is possible via communication (USB, CAN, RS-485)
Commands set via communication cannot be released by terminal input. Reset execution is always required.
 [Response time] Response time can be set: 1 to 1999 ms
 [Backup] Possible to back up values during shift and set operations. (values can be retained even when power is turned off)
Setting value memory Nonvolatile memory (EEPROM)
   
Display
Display Color [Standard] ST-4801 Red LED / [Option] ST-4801-G Green LED
Indicator (Numerical Display) 6-digit, 7-segment LED Character height 14.2mm
[Display range] -199999 to 999999
[Over indication] OL
[Zero indication] Leading zero suppress
Decimal point position Semi-fixed Decimal point position is set in program mode.
[0] ******,  [1] *****.* to [4] **.****
Indicator (4 round LEDs) [IN ] Not used
[RUN ] Lights up when function setting is ON (function setting is available)
[COMP1] Lights up when comparator/Alarm output 1 is ON (option)
[COMP2] Lights up when comparator/Alarm output 2 is ON (option)
   
USB communication
Specification USB2.0 (Serial port communication by USB virtual COM 230.4kbps)
Function Writing/reading of set values/continuous output of measured values
Output update time 1 to 9999ms, settable in 1ms increments
   
General
Operating temp./humidity -10°C to +50°C / 35 to 85%RH (non-condensing)
Power supply voltage
[Selevt a model]】
ST-4801-AF: AC100-240V (Maximum rated AC85-264V) 50/60Hz
ST-4801-DF: 12-30V DC with reverse connection protection
Power consumption 3W or less
Isolation Power Supply/ Voltage input /Other Input/output
Withstand voltage Between each terminal of the above isolations: 500V DC between each terminal for 1 minute.
Weight Approx. 340g
   
CAN Option
Sspecifications CAN2.0B 10 k / 20 k / 50 k / 100 k / 250 k / 500 k / 1M bps
[Format] INTEL/MOTOROLA, [Frame] 11bit/29bit
Function Writing/reading of set values/continuous output of measured values
Setting item CAN transmit ID, CAN receive ID
Output update time 1 to 9999ms, settable in 1ms increments
   
RS-485 Option 
Number of connected units 32 units max.
Communication format 2-wire multi-drop serial communication
Communication method Asynchronous
Communication standard RS-485
Communication speed 9600 / 19200 / 38400bps Set in program mode
Data format Start bit: 1 bit / Stop bit: 1 bit / Data length: 8 bits / Parity bit: None
Communication code ASCII
Communication function
Writing/reading set values/measurement value output (response to request command)
Modbus RTU support is available upon request.
   
Analog output option
Output signals [E1] 0 to 10 V, [E5] 0 to 5 V, [R1] ±10 V, [R5] ±5 V, [I1] 4 to 20 mA    [Select a model]
D/A conversion DAC conversion method
Output resolution 16bit (50,000 or more)
Load resistance [Voltage output] 4.7kΩ or more
[Current output] 300Ω or less
Output accuracy [Voltage output] ±0.1% of FS @ 23°C
[Current output] ±0.1% of FS @ 23°C
Temperature fluctuation ±200ppm/℃ or less
Output scaling Arbitrary scaling is possible by full scale and zero scale settings
Output update time 1 to 9999ms, settable in 1ms increments
   
Alarm [Comparator] output option
Setting method Set in program mode
Number of outputs 2 / 4 points  [Select a model]
Output form Isolated non-contact output (photo-MOS relay) No polarity.
When comparator operating condition is ON, resistance between COMP and COM: 50 Ω or less
Output load voltage Peak AC/DC280V 100mA (resistive load) / ON resistance 50Ω or less
Output logic Comparison is made with polarity (0 is greater than minus)
[Over] ON when set value or more / [Under] ON when set value or less/
[Within range] ON within the set value, OFF outside the range
[Out of range] ON outside the set value, OFF inside the range
Update time Depends on analog output update time setting. Response time 1ms (max)

Other measurements

 View more > 
CAN analog conversion DC current DC voltage
Thermocouple [temp.] Thermistor [temp.] RTD [temp.]
Speed/Count Frequency deviation/torque Resistance

CAN, 16bit analog, Alarm, RS-485, Modbus

 Various Outputs

Smart configuration / Prevents unintentional operation

 Software LINKSHIP

USB Type-C standard equipment

 For data logging, setting

Built in box, multi-CH, and function changes, etc

 Customization


EX48