- Fuel consumption is measured in order to study fuel-efficient vehicles and to determine differences in fuel consumption depending on driving methods.
- The following is an example of detecting the fuel flow rate (going side - returning side = actual amount of fuel used) from a fuel tank of a car or other vehicle to the engine.
→ Pulse signal |
Measuring instrument |
→ Analog output Analog output Alarm output CAN RS-485 etc. |
PC Logger Oscilloscope etc. |
What we can do with measurement
- The XFS series of flow sensors are compact and can measure even very low flow rates with high accuracy.
- The unique Periomatic™ calculation method enables high accuracy and high speed response to startup from a standstill, ultra-low speed, high speed, and sudden flow rate changes.
- The SPD/SPDL series can measure instantaneous flowrate/integrated flowrate switchably.
- PFC-4921 can display and measure both instantaneous and totalized flow rates simultaneously.
Selection Points
Flow sensor
- Capable of displaying and measuring from very low flow rates (XFS series)
- Pulse output is resistant to noise during long-distance transmission. 2.
Measuring instruments
- 0.5ms (TDP-49), 0.1ms (SPD series), 1ms (PFC-4921), 40ms (SPDL series) update analog output
- CAN communication with 1ms (SPD series) and 40ms (SPDL series) updates
- Periomatic™ calculation method for high accuracy and fast response even at ultra-low speeds
- Factory setting of the instrument and creation of a set value table are available when ordered as a set with a flow sensor.
Products | Points | Overviews | |
---|---|---|---|
XFS series |
- Special elliptical gear minimizes pressure loss and provides highly accurate measurement from low to high flow ranges. | ||
TDP-4921/TDP-4931 |
RS-485 RS-232C Analog output Alarm output BCD output LINKSHIP support |
- 16-bit analog output with 0.5ms update |
|
SPD-4801 |
RS-485 Modbus CAN Analog output Alarm output Zero shift Span shift Count Stop/Start LINKSHIP support |
- 48x96 size speed/totalizer [switchable] for frequency meter, tachometer, flowmeter, speed meter, totalizer, etc. |
|
SPD-2401 SPDL-2401 |
RS-485 Modbus CAN Analog output Alarm output Zero shift Span shift Count Stop/Start LINKSHIP support |
- 24x48 size speed/totalizer [switchable] for frequency meter, tachometer, flowmeter, speed meter, totalizer, etc. |
|
SPD-HD |
RS-485 Modbus CAN Analog output Alarm output Zero shift Span shift Count Stop/Start LINKSHIP support |
- Speed/totalizer [switchable] for frequency meter, tachometer, flowmeter, speed meter, totalizer, etc. |
|
PFC-4921 |
Reset input Start input Stop inpu Analog output Quadruplicated measurement Scaling function Totalizer backup Alarm output LINKSHIP support |
- Simultaneous measurement of instantaneous flowrate (L/min, etc.) and totalized flowrate (mL, etc.) - Quadruplicated measurement function - 16-bit analog output with fastest 1ms update - Up to 4 alarm outputs - 48x96 size panel meter with scaling function - LINKSHIP" compatible for PC setting |
|
CRM-281 2-input transfer deviation meter |
2ch input Analog output Data logging Re-pulse output Quadruplicated measurement Scaling function Count value backup |
- Analog output update 100μs - Simultaneous 2-channel analog outputs for instantaneous flowrate, instantaneous flowrate difference, totalized flowrate, totalized flowrate difference, and ring counter - Speed ratio setting |