DC Ammeter PSA-4801 Digital panel meter, signal converter, indicating alarm meter, distributor

Option/ Models
Dimesions
DXF data
Manual Downloads
Software

For real-time PWM current measurement, feedback control, etc.

Average current per output update time is measured with a ΣΔAD converter with oversampling of approximately 250 kHz. Rates can be set as desired.

Inputs
PWM drive current
Battery charging current
Microcurrent
Solenoid
Battery
Motor
Clamp-on sensor
Power supply for sensor
・12V/5V/others
 
Calculation
・Oversampling 250kHz
・Moving average Max. 99
・Low cut
・HOLD [Current value/Max. value/Min. value/Max. variation range]
Zero/Span shift, Zero/Span set
PSA-4801
Power supply
・DC9.6-30V
・AC100-240V
Setting
・Front button on main unit
・Special software LINKSHIP
・External setting unit PL-5A
   
Output
16bit analog
CAN
Ethernet
RS-485
Alarm
USB

PC, PLC, Logger, Oscilloscope, Indicators, etc.

     
Various applications
Current-to-CAN conversion
Internal current measurement
Micro Current Leak Tester
PWM current measurement
Charging current measurement

13 models by input range
Input resolution 10.4ns

Please select the input range when ordering. Please consult us for ranges other than those listed below.
±10A
±5A
±2A
±1A
±200mA
±100mA
±20mA
±10mA
±2mA
±1mA
±200μA
±100μA
4(0)-20mA*
*Process signal support

Customization - built into box, multi-CH, etc.

 >Read more 
- Flexible measurement types and number of CHs
- Convenient, easy, low cost
- Change functions Power supply, output voltage, communication specifications, etc.
- Support from a single unit
- Calibration as a built-in product is available.
- Calibration documents and traceability charts can be issued

Built into box

>Learn more

Backside

>Learn more

Multi CH in a box

>Learn more

Multi CH with display

>Learn more

HDMI output + display software

>Learn more

Rack Mounted

>Learn more

Output 1ms update

CAN [Option]]

3-wire wiring greatly reduces wiring compared to BCD
Powerful error detection system for improved noise immunity and safety

SAE J1939 [DLC 8 bytes or less] Customization experience available
Please contact us for other customizations.

RS-485 [Option]

16bit analog [Option]
Resolution 50,000 or more/Full scale and zero scale settings, output zero adjustment


Alarm [Option] 1 to 4points [Depends on model]


USB Type-C [Standard feature] Data logging, setting


PSA-4801 Standard Model  35,800 yen and up [tax not included]

 > See options and price list   *Prices as of February 2024

Easy setup, measurement and installation For ease of use on site

Front operation. Setting and measuring

(A) Operation indicator LED
(B) Front sheet button
- [In program mode] MODE, digit selection, numeric setting, ENTER
- [In measurement mode] Span shift, Zero shift
- Key lock: Prevents unintentional operation by field workers.


Blue/pink type[Option]]
*Designs are subject to change.
Mounting hooks [Left and right] For fixing the main unit

Smart configuration and logging Setting management, report printing, and CSV logging with dedicated software LINKSHIP [free of charge]

 > Download page 

CSV logging


Logging is possible by specifying the number of seconds. Custom logger software is available.

Compare and match set value lists


Multiple lists of set values can be compared and collated.

PC save and copy of set values


It prevents errors in note-taking and manual entry, and reduces management effort and costs.

Prevention of misoperation


Settings and confirmations can be made on the PC screen, preventing misoperation of the main unit's buttons.

Quickly set up multiple units



Even multiple units can be easily configured by simply writing the configuration data.

USB Type-C connector standard:For configuration and logging

Setup unit without LINKSHIP or PC required: [sold separately]


>PL-5A Product page
*Setting only / data logging and power supply not available

Power supply: 9.6 to 30VDC / 100 to 240VAC [Select a model]

Isolation Electrical isolation between power supply/voltage input/other inputs and outputs

Application

 Applications list> 


Real-time measurement of PWM drive current of solenoid valves, etc.


Measurement of CCCV charging current of lithium-ion battery


Understanding Current Measurement. Advantages of the PSA Series


Current to CAN conversion


Easy and accurate current measurement with clamp sensor


Wind Tunnel Testing / vehicles, motorcycles, architectural and civil engineering structures, etc.

Specifications

Name DC Ammeter
Model PSA-4801
Measuring method ΔΣ integral method
   
Input
Number of input 1 point
Measuring range
Model Range Terminal withstand Resolution
±10A -10000.0mA to +10000.0mA -11A to +11A 0.5mA
±5A -5000.0mA to +5000.0mA -6A to +6A 0.25mA
±2A -2000.0mA to +2000.0mA -3A to +3A 0.1mA
±1A -1000.0mA to +1000.0mA -3A to +3A 0.05mA
±200mA -200.00mA to +200.00mA -3A to +3A 0.01mA
±100mA -100.00mA to +100.00mA -3A to +3A 0.005mA
±20mA -20.000mA to +20.000mA -3A to +3A 0.001mA
±10mA -10.000mA to +10.000mA -3A to +3A 0.001mA
±2mA -2.0000mA to +2.0000mA -3A to +3A 0.001mA
±1mA -1.0000mA to +1.0000mA -3A to +3A 0.001mA
±200μA -200.00μA to +200.00μA -0.05A to +0.05A 0.05μA
±100μA -100.00μA to +100.00μA -0.05A to +0.05A 0.05μA
4-20mA +4.0000mA to +20.000mA 0A to +3A 0.001mA
Measurement accuracyy ±0.1%FS +1digit
Oversampling 250kHz fixed
Input low-pass filter Cut-off frequency 1kHz
Input connector Terminal block 7.62mm pitch M3 free terminal screw
Sensor Power supply -
output [Option]
[H] DC+12V±5% 60mA max/ [L] DC +5V±5% 150mA max
   
Calculation
Output moving average 1 to 99 [Display moving average]1 to 9
Low cut Current below the set value is judged as 0.
Control input None or 1 point (depending on model)   [D2] Option adds 2 points
[Settings] Set functions per control input (CTL) for external control
[Functions] Hold (current value, max value, min value, max fluctuation range),
zero shift, span shift, zero set, span set
[ON Logic] Normally open, normally closed
[Operation] Control Input (CTL*) Terminal (ON Logic):
Short to GND (Open) for ON, Open (Short) for setting content to take effect
[Commnication] Command control possible via communication (USB, CAN, RS-485)
*Commands set via communication cannot be canceled by terminal input. Reset execution is always required
[Response Time] configurable (1ms to 1999ms)
[Backup] Enable/disable backup of values during shift and set operations (values retained even after power off)
Setting Value Memory Non-volatile Memory (EEPROM)
   
Display
Indicator
(Numerical Display)
6-digit, 7-segment LED Character height 14.2mm
[Standard] PSA-4801 Red LED / [Option] PSA-4801-G Green LED
Display range: -199999 to 999999
Over indication: OL / Zero indication: Leading zero suppress
Decimal point position Semi-fixed, set in program mode. [0] ******,  [1] *****.* to [4] **.****
Update time 0.3 sec (settable from 0.1 to 9.9 sec)
Display accuracy 20ppm ±1digit
Indicator
4 round LEDs
[IN] Not in use
[RUN] Illuminates when function setting is ON
[COMP1][COMP2] Illuminates when comparator output is ON [Option]
   
USB communication
Specification USB2.0 (Serial port communication by USB virtual COM 230.4kbps)
Function Writing/reading of set values/continuous output of measured values
Update time 1 to 9999ms Settable in 1ms increments
   
General Information
Operating temp./humidity -10°C to +50°C / 35 to 85%RH (non-condensing)
Power supply
[Select a model]
[AF] 100-240VAC (Maximum rated 85-264VAC) 50/60Hz
[DF] 9.6-30VDC (Maximum rated 9-36VDC) with reverse connection protection
Power consumption 3W or less
Isolation Power supply / Current input / Other input/output
Withstand voltage Between each terminal of the above isolation:
DC 500V for 1 minute
Weight Approx. 340g
   
CAN option
Specifications CAN2.0B 10 k / 20 k / 50 k / 100 k / 250 k / 500 k / 1M bps
[Format] INTEL/MOTOROLA, [Frame] 11bit/29bit
Function Writing/reading of set values/continuous output of measured values
Setting item CAN transmit ID, CAN receive ID
Update time 1 to 9999ms  Settable in 1 ms increments
   
RS-485 communication option Modbus RTU support is available upon request.
Connected units 32 units [max.]
Format 2-wire multi-drop serial communication
Method Asynchronous
Standard RS-485
Speed 9600bps / 19200bps / 38400bps Set in program mode
Data format Start bit: 1 bit / Stop bit: 1 bit / Data length: 8 bits / Parity bit: None
Communication code ASCII
Function Writing/reading set values/measurement value output [response to request command]
   
Analog output option
Output signals [E1] 0 - 10V [E5] 0 - 5V [R1] ±10V [R5] ±5V [I1] 4 - 20mA  [Select a model]
D/A conversion method DAC conversion method
Output resolution 16bit [50,000 or more]
Load resistance [Voltage output] 4.7kΩ or more / [Current output] 300Ω or less
Output accuracy [Voltage output] ±0.1% of FS @ 23℃/ [Current output] ±0.1% of FS @ 23℃
Temperature fluctuation ±200ppm/℃ or less
Output scaling Arbitrary scaling is possible by full scale and zero scale settings
Update time 1 to 9999ms settable in 1ms increments
Input/output delay time Output update time + analog rise time 150 μs max.
   
Alarm [Comparator] output option
Setting method Set in program mode
Number of outputs 2 to 4 points [depends on the models]
Output form Isolated non-contact output [photo-MOS relay] No polarity.
When comparator operating condition is ON, resistance between COMP and COM: 50 Ω or less
Output load voltage Peak AC/DC280V 100mA [resistive load] / ON resistance 50Ω or less
Output logic Comparison is made with polarity [0 is greater than minus]
[Over] ON when set value or more
[Under] ON when set value or less
[Within range] ON within the set range, OFF outside the range
[Out of range] ON outside the set range, OFF within the range
Update time Depends on analog output update time setting. Response time 1ms [max.]
   
Ethernet Communication option
Connector RJ-45 (Network Interface) Lantronix XPort
Interface 100BASE-TX/10BASE-T (Auto-sensing)
Transmission Speed Standard: Category 5/Category 4
Specifications Protocol: TCP/IP Method: Telnet Communication Connection
Output update Same as USB communication 1 to 9999ms
Transmission Compatibility DIX Ethernet Version2.0 IEEE 802.3
LED Indicators 100BASE-TX/10BASE-T
Link/Activity Indicator Full Duplex/Half Duplex (Telnet cannot handle encrypted communication networks using SSL/TLS or SSH)
   

Related Products 

Ammeters list>
All Products>

Other measurement categories:EX Series

 View List > 
Input type
Load cell/Pressure/Strain CAN to analog
DC current DC voltage
Thermocouple meter Thermistor meter
RTD meter Resistance Meter
Speed/Count, Pulse Freq. Torque/Freq.deviation

CAN, 16bit analog, Alarm, RS-485, Modbus

 Various Outputs

Smart configuration / Prevents unintentional operation

 Software LINKSHIP

USB Type-C standard equipment

 For data logging, setting

Built in box, multi-CH, and function changes, etc

 Customization


EX48