| -200°C to +850°C Measurement |
| Rate setting between two points Linear Compensation Formula |
| Input RTD |
||
Pt100![]() ![]() |
![]() |
|
| Calculation ・Moving average Max. 99 ・HOLD [Current value/Max. value/Min. value/Max. variation range] ・Zero shift |
||
HT-24R series![]() ![]() ![]() |
![]() |
|
| Power supply ・7 to 60V DC ・USB power 5V |
Setting ・LINKSHIP software ・Setting unit PL-5A |
|
| Output | |||||||
PC, PLC, Logger, Oscilloscope, Indicators, etc.
![]() |
|||||||




| >View more |
| See 40ms type> |
| SAE J1939 [DLC 8 bytes or less] Customization experience available Please contact us for other customizations. |
| See Low-cost version > |
| HT-2401R |
| 32,500 yen and up* |
| Display only, Equipped with USB communication |
| HT-2451R |
| 28,100 yen and up* |
| DIN rail mounting, no display |
| See options and price list> |
| LINKSHIP Page > |








Detachable Plug Connectors
Simply connect the wires to the connector and plug it in by hand.

Detachable Plug Connectors
Spring lock type [Standard]

Detachable Plug Connectors
M2 screw type [Option]

Fixed Connector
Non-detachable [Customize]

Mounting hooks
Fixing the main body

Carry PC, instrument, and cable, and measure with USB power supply. Storage case BXS-1 is also available.
![]() |
![]() ![]() >BXS-1 Overview |
One-touch fixture and display-less type
![]() |
![]() |
![]() |
| BXF-DN2 DIN rail attachment [sold separately] |
HT-2451R Display-less type |
HT-2431R With display type |
| >BXF-DN2 page |
| Applications list > |
| Model List, Options and Prices > |
| Name | Resistance [RTD] Thermometer | ||||||||
| Model | HT-2401R / HT-2411R / HT-2431R / HT-2451R | ||||||||
| Input | |||||||||
| Number of input | 1 point RTD[Resistance thermometer] Pt100 3-wire | ||||||||
| Measuring range | -200°C to +850°C ±0.2% of FS | ||||||||
| Resistance check function | 0Ω to 400Ω | ||||||||
| Input connector | Plug type [Standard] Spring lock / [Option] M2 screw | ||||||||
| Calculation | |||||||||
| Moving Average Number | 1 to 99 | ||||||||
| Control input | None or 1 point (depending on model) [D2] Option adds 2 points | ||||||||
| [Settings] | Set functions per control input (CTL) for external control | ||||||||
| [Functions] | Hold (current value, max value, min value, max fluctuation range), zero shift |
||||||||
| [Operation] | Control Input (CTL*) Terminal (ON Logic): Short to GND (Open) for ON, Open (Short) for setting content to take effect |
||||||||
| [Commnication] | Command control possible via communication (USB, CAN, RS-485) *Commands set via communication cannot be canceled by terminal input. Reset execution is always required |
||||||||
| Setting Value Memory | Non-volatile Memory (EEPROM) | ||||||||
| Display | |||||||||
| Display Color | [Standard] HT-2401R Red LED [Option]HT-2401R-G Green LED |
||||||||
| Indicator [Numerical Display] | 5-digit, 7-segment LED Character height 9mm Display range:-19999 to 99999 Over indication: OL / Zero indication: Leading zero suppress |
||||||||
| Decimal point position | Semi-fixed Set in program mode. [0] *****, [1] ****.* to [4] *.**** | ||||||||
| Display update time | 0.3 sec [settable from 0.1 to 9.9 sec] | ||||||||
| Display accuracy | 20ppm ± 1 digit | ||||||||
| Display Moving Average | 1 to 9 | ||||||||
| Indicator | LED 1 point [selected from power/ control input] | ||||||||
| USB communication | |||||||||
| Specification | USB2.0 [Serial port communication by USB virtual COM 230.4kbps] | ||||||||
| Function | Writing/reading of set values/ Continuous output of measured values | ||||||||
| Output update | 1 to 9999ms, settable in 1ms increments |
||||||||
| General Information | |||||||||
| Operating temp./humidity | -10°C to +50°C / 35 to 85%RH [non-condensing] | ||||||||
| Power supply | 7 to 60V DC with reverse connection protection. Power supply from USB host: 5V | ||||||||
| Power consumption | 3W or less | ||||||||
| Isolation | Power supply / RTD input / Other input/output | ||||||||
| Withstand voltage | Between each terminal of the above isolation: DC 500V for 1 minute |
||||||||
| Weight | Approx. 60g |
||||||||
| CAN Option | |||||||||
| Specifications | CAN2.0B 10 k / 20 k / 50 k / 100 k / 250 k / 500 k / 1M bps [Format] INTEL/MOTOROLA, [Frame] 11bit/29bit | ||||||||
| Function | Writing/reading of set values/ Continuous output of measured values | ||||||||
| Setting item | CAN transmit ID, CAN receive ID | ||||||||
| Output update | 1ms to 9999ms settable in 1 ms increments |
||||||||
| RS-485 communication option Modbus RTU support is available upon request. | |||||||||
| Connected units | 32 units [max.] | ||||||||
| Format | 2-wire multi-drop serial communication | ||||||||
| Method | Asynchronous | ||||||||
| Standard | RS-485 | ||||||||
| Speed | 9600bps / 19200bps / 38400bps Set in program mode | ||||||||
| Data format | Start bit: 1 bit / Stop bit: 1 bit / Data length: 8 bits / Parity bit: None | ||||||||
| Code | ASCII | ||||||||
| Function | Writing/reading set values/measurement value output [response to request command] |
||||||||
| Analog output option | |||||||||
| Output signals | [E1] 0 - 10V [E5] 0 - 5V [R1] ±10V [R5] ±5V [I1] 4 - 20mA [Select a model] | ||||||||
| D/A conversion | DAC conversion method | ||||||||
| Output resolution | 16bit [50,000 or more] | ||||||||
| Load resistance | [Voltage output] 4.7kΩ or more / [Current output] 300Ω or less | ||||||||
| Output accuracy | [Voltage output] ±0.1% of FS @ 23℃/ [Current output] ±0.1% of FS @ 23℃ | ||||||||
| Temp. fluctuation | ±200ppm/℃ or less | ||||||||
| Output scaling | Arbitrary scaling is possible by full scale and zero scale settings | ||||||||
| Output update | 1 to 9999ms settable in 1ms increments | ||||||||
| Input/output delay | Output update time + analog rise time 150 μs max. |
||||||||
| Alarm [Comparator] output option | |||||||||
| Setting method | Set in program mode | ||||||||
| Number of outputs | 1 to 4 points [depends on the models] 1 point for line driver input and analog output with comparator output specification. | ||||||||
| Output form | Isolated non-contact output [photo-MOS relay] No polarity. When comparator operating condition is ON, resistance between COMP and COM 50 Ω or less |
||||||||
| Output load voltage | Peak AC/DC280V 100mA [resistive load] / ON resistance 50Ω or less | ||||||||
| Output logic | Comparison is made with polarity [0 is greater than minus]
|
||||||||
| Update time | Depends on analog output update time setting. Response time 1ms [max.] | ||||||||
| All products> | Temperature meters> |
| View List > |
| Load cell/Pressure/Strain | CAN to analog |
| DC current | DC voltage |
| Thermocouple meter | Thermistor meter |
| RTD meter | Resistance Meter |
| Speed/Count, Pulse Freq. | Torque/Freq.deviation |
Various Outputs
Software LINKSHIP
For data logging, setting
Customization