| CAN output |
| Versatile excitation voltage |
| Bridge Resistance 120Ω/350Ω |
Rating can be set arbitrarily.
With versatile input ranges and hold/control functions, it can also be used as a scaling meter.
| Input | |||
Strain Gauges, Load Cells, Pressure, Displacement, Acceleration Sensors ![]() |
![]() |
||
| Sensor Power Supply ・2.5V/5V/10V/Other Voltages |
| ||
| Calculation/Signal Conversion | |||||||
STL-24 Series
|
![]() |
||||||
| Power Supply ・DC7-30V |
Settings ・Dedicated Software LINKSHIP ・External Setting Unit PL-5A |
||||||
| Output | ||||||
PC・PLC・Logger・Oscilloscope・Indicator Light, etc. ![]() ![]() |
| 2.5V |
| 5V |
| 10V |
| Other voltages |
| 120Ω |
| 350Ω |
















| >View more |
| See 1ms type> |
| SAE J1939 [DLC 8 bytes or less] Customization experience available Please contact us for other customizations. |
| LINKSHIP Page > |








Detachable Plug Connectors
Simply connect the wires to the connector and plug it in by hand.

Detachable Plug Connectors
Spring lock type [Standard]

Mounting hooks
Fixing the main body

Carry PC, instrument, and cable, and measure. Storage case BXS-1 is also available.
![]() |
![]() ![]() >BXS-1 Overview |
One-touch fixture and display-less type
![]() |
![]() |
![]() |
| BXF-DN2 DIN rail attachment [sold separately] |
STL-2451 Display-less type |
STL-2431 With display type |
| >BXF-DN2 page |
| Option/ Models> |
| Tyoe | STL-2401 |
| Input | |
| Input signal | 1 point Load cell signal |
| Bridge Resistance | 120Ω / 350Ω excitation voltage:2.5V / 5.0V / 10.0V (±7%) |
| Measuring range | ±5.1mV/V ADC resolution 60,000 or higher Operable with specifications equivalent to the reference below: ・Span adjustment range: 1-4mV/V ・External shunt resistor adjustment range: Covers 40%-100% (factory default 80%) ・Zero adjustment range: -100% to 25% FS |
| Minimum Input Sensitivity | 1μV/digit at Bridge voltage 5V 2μV/digit at Bridge voltage 10V |
| Measurement Accuracy | ±(0.1% of FS + 1digit)@23℃ 35-85% *Sampling rate, 20 times/sec or less |
| Temperature Characteristics | Zero: 0.02% FS/°C, Span: 0.02% FS/°C |
| Sampling Rate | 1000 times/sec *ΔΣ AD conversion method |
| Sensor Power Supply Output | 2.5V/5V/10V/Other voltage [Select Model] |
| Calculation | |
| Measuring method | ΔΣ integral method |
| Moving Average Number | 1 to 99 |
| Control input | 2 or 4 points [Varies depending on model.] Functions and ON logic can be set for each CTL for external control. |
| [Functions] | Hold (current/max./min. value, max. fluctuation range), zero/span shift, zero/span set |
| [ON logic] | Normally open /normally closed |
| [Operation Method] | ON when control input (CTL*) pin (ON logic) is shorted (open) to GND; setting is reflected when open (shorted). |
| [Data communication] | Command control is possible via communication (USB, CAN, RS-485) Commands set via communication cannot be released by terminal input. Reset execution is always required. |
| [Response time] | Response time can be set: 1 to 1999 ms |
| [Backup] | Possible to back up values during shift and set operations. (values can be retained even when power is turned off) |
| Setting value memory | Nonvolatile memory (EEPROM) |
| Display | |
| Display Color | [Standard] STL-2401 Red LED |
| Numerical Display | 5-digit, 7-segment LED Character height 9mm |
| [Display range] | -19999 to 99999 |
| [Over indication] | OL |
| [Zero indication] | Leading zero suppress |
| [Display update time] | 0.1 - 9.9s /Factory default setting: 0.3s |
| [Display accuracy] | 20 ppm ± 1 digit at 23°C |
| Decimal point position | Semi-fixed Decimal point position is set in program mode. [0] ******, [1] *****.* to [4] **.**** |
| Indicator (4 round LEDs) |
[IN ] Not used [RUN ] Lights up when function setting is ON (function setting is available) [COMP1] Lights up when comparator/Alarm output 1 is ON (option) [COMP2] Lights up when comparator/Alarm output 2 is ON (option) |
| USB communication | |
| Specification | USB2.0 (Serial port communication by USB virtual COM 230.4kbps) |
| Function | Writing/reading of set values/continuous output of measured values |
| Output update time | 40 to 9999ms, settable in 1ms increments |
| General | |
| Operating temp./humidity | -10°C to +50°C / 35 to 85%RH (non-condensing) |
| Power supply voltage | 7-30V DC with reverse connection protection |
| Power consumption | 3W or less |
| Isolation | Power Supply/ Voltage input /Other Input/output |
| Withstand voltage | Between each terminal of the above isolations: 500V DC between each terminal for 1 minute. |
| Weight | Approx. 60g |
| CAN Option | |
| Sspecifications | CAN2.0B 10 k / 20 k / 50 k / 100 k / 250 k / 500 k / 1M bps [Format] INTEL/MOTOROLA, [Frame] 11bit/29bit |
| Function | Writing/reading of set values/continuous output of measured values |
| Setting item | CAN transmit ID, CAN receive ID |
| Output update time | 40 to 9999ms, settable in 1ms increments |
| RS-485 Option | |
| Number of connected units | 32 units max. |
| Communication format | 2-wire multi-drop serial communication |
| Communication method | Asynchronous |
| Communication standard | RS-485 |
| Communication speed | 9600 / 19200 / 38400bps Set in program mode |
| Data format | Start bit: 1 bit / Stop bit: 1 bit / Data length: 8 bits / Parity bit: None |
| Communication code | ASCII |
| Communication function |
Writing/reading set values/measurement value output (response to request command) Modbus RTU support is available upon request. |
| Analog output option | |
| Output signals | [E1] 0 to 10 V, [E5] 0 to 5 V, [R1] ±10 V, [R5] ±5 V, [I1] 4 to 20 mA [Select a model] |
| D/A conversion | DAC conversion method |
| Output resolution | 16bit (50,000 or more) |
| Load resistance | [Voltage output] 4.7kΩ or more [Current output] 300Ω or less |
| Output accuracy | [Voltage output] ±0.1% of FS @ 23°C [Current output] ±0.1% of FS @ 23°C |
| Temperature fluctuation | ±200ppm/℃ or less |
| Output scaling | Arbitrary scaling is possible by full scale and zero scale settings |
| Output update time | 40 to 9999ms, settable in 1ms increments |
| Alarm [Comparator] output option | |
| Setting method | Set in program mode |
| Number of outputs | 2 / 4 points [Select a model] |
| Output form | Isolated non-contact output (photo-MOS relay) No polarity. When comparator operating condition is ON, resistance between COMP and COM: 50 Ω or less |
| Output load voltage | Peak AC/DC280V 100mA (resistive load) / ON resistance 50Ω or less |
| Output logic | Comparison is made with polarity (0 is greater than minus) [Over] ON when set value or more / [Under] ON when set value or less/ [Within range] ON within the set value, OFF outside the range [Out of range] ON outside the set value, OFF inside the range |
| Update time | Depends on analog output update time setting. Response time 1ms (max) |
| View more > |
| CAN analog conversion | DC current | DC voltage |
| Thermocouple [temp.] | Thermistor [temp.] | RTD [temp.] |
| Speed/Count | Frequency deviation/torque | Resistance |
Various Outputs
Software LINKSHIP
For data logging, setting
Customization