COCORESEARCH - Measuring Instrument Manufacturer
Products
Applications
Technical Info
Support
Company
Careers
Inquiry
JAPANESE
PAGE
TOP

Water Level Measurement & Control for Tanks, etc. Using Distributors

Supplies driving power to 2-wire transmitters such as water level meters and level sensors using a distributor, and converts the received signals into DC current/voltage signals.
In addition, alarm outputs can be configured based on water level or flow rate (e.g., OFF at 90%, ON at 40%) to be utilized as pump ON/OFF signals.

Overview

2-Wire Transmitter
Differential Pressure Meters, Water Level Meters, Level Sensors, Flowmeters, etc.
Power Supply
DC 24V


Instrumentation Signal
4-20mA
Distributor


Without Display


With Display

Analog Output
1(0)-5V, etc.

Alarm
RS-485
CAN


PLC /
Controllers, etc.
 
Alarm Output
OFF when level
is 90% or higher

ON when level
is 50% or lower
etc.

Capabilities

For water level measurement in tanks, signals from 2-wire transmitters (sensors, etc.) can be converted into analog signals to import data.
Power supply to the 2-wire transmitter can be performed simultaneously.
Analog output can achieve up to a 1ms update rate.
Equipped with 2 to 4 alarm outputs (optional), which can be used as control signals for turning pumps or indicator lights ON/OFF.
While non-CAN communications acquire measurement data via a command-response method, CAN communication automatically outputs data at each update interval, reducing program development costs (depending on the selected model).

Selection Points

CAN Output for Measurement Data (Optional)
CAN Continuous Output Function
Easily acquire measured values as digital values *Depending on model

Output Update: Up to 1ms update rate

Support examples available for SAE J1939 (DLC 8 bytes or less), etc. *Please consult us
Analog Output (Optional)

Output Update: Up to 1ms~

Output Signal (Specify at the time of order)

0-10V 0-5V ±10V ±5V 4-20mA

Full-scale value can be configured

Dual analog output option available

Power Supply to Sensor (Optional)
Power supply capable for 2-wire transmitters: DC 24V / 12V / 5V, etc.
Alarm Output (Optional)
ON conditions can be configured: Above set value / Below set value / Within range / Out of range
Low Cost
Low-cost version PSAL / PSVL Series:
Analog output and CAN communication feature a 40ms update rate

Product Introduction Distributors by COCORESEARCH

Common Features (DC Current Input / Voltage Input Types)
 View Series List > 
16-bit Analog Output
1ms update rate: 4-20mA, 1-5V, etc. Simultaneous output with CAN is available
CAN
1ms update rate. Simultaneous output with analog output is available
USB Type-C Connector
Logging & Configuration
If power supply to the transmitter is not required, the 24** type can also operate via 5V USB power
Alarm Output
2 to 4 points. ON conditions can be configured individually (Above / Below / Out of range / Within range)
2-Point Rate Configuration
Linear scaling equation
Zero / Span Configuration
Zero / Span Shift · Zero / Span Set
Measurement Management Software LINKSHIP (Free)
Configuration management / Report printing. Easy setup
With Display
Visual check of converted values is also available (4801, 2401, 2431 types)
Isolation
Isolated between power supply / current (voltage) input / other inputs and outputs

DC Current Input Type

13 Input Range Models, 10.4ns Input Resolution

Select input range at the time of order (Please consult us for ranges other than below)

±10A
±10mA
±5A
±2mA
±2A
±1mA
±1A
±200μA
±200mA
±100μA
±100mA
4(0)-20mA*
±20mA
*Process signal compatible

40mΩ Shunt Resistance* Substantially Reduces Resistance Loss

For various applications

DC Current Measurement
Leakage Current Measurement
PWM Current Measurement
Charging Current Measurement
Current-to-CAN Conversion
*The 40mΩ shunt resistance is for ±10A / ±5A / ±2A models.

Understand Current Measurement! Advantages of the PSA Series Basics of measurement, shunt resistance, low-side / high-side measurement, etc.
 View Details > 

Lineup


PSA-4801

 Details > 

48x96 mm Size

Analog Output & Digital Comm.
1-9999ms Update

Power Supply
AC100-240V / DC9.6-30V

Display: 6 Digits
Green LED type also available

Dimensions: W96, H48, D99 mm

Front Configuration Buttons


PSA-24

 Details > 

Easy-to-use 1-CH Type

Analog Output & Digital Comm.
1-9999ms Update

Power Supply
DC7-60V / 5V USB Bus Power

Display: 5 Digits
Green LED type also available

Dimensions: W48, H24, D106 mm
24x48 mm DIN Size

DIN Rail Mount Compatible


PSAL-24

 Details > 

Easy 1-CH Low-Cost Model

Analog Output & Digital Comm.
40-9999ms Update

Power Supply
DC7-30V / 5V USB Bus Power

Display: 5 Digits
Red LED only

Dimensions: W48, H24, D106 mm
24x48 mm DIN Size

DIN Rail Mount Compatible




With SD Logger

 Details > 

Save Logging Data on Card

Front Buttons
Start / Stop Logging

1-CH Input

Output
CAN
16-bit Analog (Volt/Current)
Alarm
Ethernet
HDMI

Power Supply
AC100V / DC8-30V, etc.
Selectable Connectors
BNC / M8 / Terminal Block, etc.



Compact Multi-CH

 Details > 

Lightweight for On-Vehicle Use

Multi-CH Input Customized Product

Output
CAN
16-bit Analog (Volt/Current)
Alarm
Ethernet
HDMI

Power Supply: DC8-30V
Display: Selectable With/Without
Selectable Connectors
BNC / LAN / D-sub / Terminal Block

DC Voltage Input Type

13 Input Range Models, 10.4ns Input Resolution

Select input range at the time of order (Please consult us for ranges other than below)

±70V
±200mV
±30V
±100mV
±20V
±20mV
±10V
±10mV
±5V
0-10V*
±2V
1(0)-5V*
±1V
*Process signal compatible

For Various Applications

Can be used for multiple purposes beyond water level

Pressure Measurement
Displacement Measurement
Flow Rate Measurement
Voltage-to-CAN Conversion
DC Voltage Measurement

Lineup


PSV-4801

 Details > 

48x96 mm Size

Analog Output & Digital Comm.
1-9999ms Update

Power Supply
AC100-240V / DC9.6-30V

Display: 6 Digits
Green LED type also available

Dimensions: W96, H48, D99 mm

Front Configuration Buttons


PSV-24

 Details > 

Easy-to-use 1-CH Type

Analog Output & Digital Comm.
1-9999ms Update

Power Supply
DC7-60V / 5V USB Bus Power

Display: 5 Digits
Green LED type also available

Dimensions: W48, H24, D106 mm
24x48 mm DIN Size

DIN Rail Mount Compatible


PSVL-24

 Details > 

Easy 1-CH Low-Cost Model

Analog Output & Digital Comm.
40-9999ms Update

Power Supply
DC7-30V / 5V USB Bus Power

Display: 5 Digits
Red LED only

Dimensions: W48, H24, D106 mm
24x48 mm DIN Size

DIN Rail Mount Compatible




With SD Logger

 Details > 

Save Logging Data on Card

Front Buttons
Start / Stop Logging

1-CH Input

Output
CAN
16-bit Analog (Volt/Current)
Alarm
Ethernet
HDMI

Power Supply
AC100V / DC8-30V, etc.
Selectable Connectors
BNC / M8 / Terminal Block, etc.



Compact Multi-CH

 Details > 

Lightweight for On-Vehicle Use

Multi-CH Input Customized Product

Output
CAN
16-bit Analog (Volt/Current)
Alarm
Ethernet
HDMI

Power Supply: DC8-30V
Display: Selectable With/Without
Selectable Connectors
BNC / LAN / D-sub / Terminal Block

Smart Configuration & Logging

Manage configurations, print reports, and perform CSV logging with the dedicated free software LINKSHIP.
 View LINKSHIP Page > 

CSV Logging



Logging available by specifying intervals in seconds. Logger software customization is also available.

Compare & Verify Configurations



Compare and verify multiple configuration parameter lists.

Save & Copy via PC



Prevents handwriting and manual entry errors, while reducing management hours and costs.

Prevent Operation Errors



Configure and verify settings directly on the PC screen to prevent accidental hardware button errors.

Reduce Configuration Labor



Copy the master configuration file to instantly write data into multiple devices.

USB Type-C Standard Equipment


Front USB: Config, Logging, Power Supply


Configuration, logging, and power supply are also available via rear terminals*. Rear USB types are also available.
*Configuration and logging from the rear terminal block require CAN or RS-485 options.
*For load cells and pressure gauges ST(L), please supply power from the rear terminal block rather than the USB connector.


Rear USB: Config & Logging


Configuration is also possible via front buttons or rear terminal blocks.
*Configuration and logging from the rear terminal block require CAN or RS-485 options.



Ethernet (LAN) options are also available.

Handheld Configurator: No LINKSHIP or PC Required
[Sold Separately]



 PL-5A Product Page > 


*For configuration use only. Data logging and power supply functions are not supported.


Easy Wiring & Installation

Designed for On-site Usability

Detachable Plug Connector
Simply wire to the connector and plug it in

Detachable Plug Connector
Spring-Lock Type [Standard]


Detachable Plug Connector
M2 Screw Type [Option]

Fixed Connector
[Custom Support]


Mounting Hooks [Left & Right]
Attach and detach the body easily without tools




Front Panel Config & Measurement
Equipped with a key-lock function to prevent misoperation


(A) Operation Status LED
(B) Front Sheet Buttons
[Program Mode]: MODE / Digit Selection / Value Adjustment / ENTER
[Measurement Mode]: Span Shift / Zero Shift
Key lock, etc.



Front Panel Blue/Pink Type [Option]
*The design is subject to change without notice.


Mounting Hooks [Left & Right]
Attach and detach the body easily without tools

Versatile Usage Methods

Portable Measurement


Carry your PC, tablet, this instrument, and cables to measure using USB power supply*. Storage case BXS-1 (sold separately) is also available.
*For load cells and pressure gauges ST(L), please supply power from the rear terminal block rather than the USB connector.



> BXS-1 Overview

Panel Integration


Contributes to space-saving with its 24x48 mm compact size.


> 24x48 mm Size Dimensional Drawing

DIN Rail Mounting


One-touch mounting fixtures and models without displays are available.

BXF-DN2
DIN Rail Fixture (Sold Separately)
2451 Type
Without Display
2431 Type
With Display
> BXF-DN2 Product Page > View Description of 2451 & 2431

Enclosures, Multi-CH Options Available [Customizable Solution - Please Consult Us]

 View Examples > 
Flexible Measurement Types & CH Counts
Available from a Single Unit
Convenient, Easy, and Low Cost
Calibration as an Integrated System is Available
Feature Mod: Power Supply, Output Volt, Comm. Specifications, etc.
Calibration Certificates & Traceability Charts Can Be Issued

Customization Examples [Available for Purchase]

Enclosures

 Details > 

Multi-CH with Display

 Details > 

HDMI Output + Software

 Details > 

With SD Logger

 Details > 

Rack Integration

 Details > 

Special Specifications

 Details > 

Selectable Connectors, Display Availability, Power Supply, etc.

Connectors
Terminal Block
Thermocouple
Banana Plug
BNC
       
LAN
USB-C
D-sub
HDMI
       
Display
With LCD Monitor Without Monitor External Monitor
With Display Software
*Monitor not included
Power Supply
AC

DC

> Inquiry Form