NTC Thermistor (Temperature) to CAN Converters Lineup

Convert measurement signals from NTC thermistors directly into CAN bus output.
Ideal for automotive testing, construction machinery, industrial equipment, and various fields as highly stable CAN signal converters/signal conditioners.
Measurement data is automatically output to the CAN bus at user-defined intervals, enabling seamless and simple data acquisition.

Signal Conditioners for Converting NTC Thermistor Inputs into CAN Bus Output
Input
NTC Thermistor
 
 
Conversion / Processing
・Moving Average (Max 99) ・Zero Shift
・Data HOLD [Current / Max / Min / Max Peak-to-Peak]
Thermistor Thermometer
   
CAN Bus
Automated CAN Data Output at Refresh Rate Intervals

PC, Data Acquisition Units, Loggers, etc.

 
3-wire bus topology drastically
reduces wiring compared to Ethernet/BCD
Robust error detection mechanism provides
high noise immunity and superior safety
SAE J1939 support options available
(DLC up to 8 bytes)

Measurement Metrics

Temperature Measurement

Versatile Applications

Product Thermal Detection
Process Control Systems

Our Wide Range of CAN Converters

Load Cell to CAN >

Excitation: 2.5V/5V/10V | Bridge: 120Ω/350Ω

Strain Gauge Load Cell Pressure Sensor Accelerometer
Current to CAN >

Supports ±100 μA to ±10 A

Battery Charge Current Solenoid PWM Current Motor Current Clamp-on
Sensors
Voltage to CAN >

Supports ±10 mV to ±70 V

Pressure Sensor Displacement Sensor ECU Signals Level Sensor
Resistance to CAN >

For Displacement & Resistance Sensors

Potentiometer Internal Resistance
Thermocouple to CAN >

For Thermocouple K, J, R, E, T, B, N, S

RTD to CAN >

Supports Pt100 RTD Elements

Speed (Frequency Pulse) to CAN >

High Precision via PeriomaticTM

Gear Sensor Flow Sensor Rotary
Encoder
Linear
Encoder
Angle/Position/Displacement to CAN >

For Length, Angle, Displacement, Flow, etc.

Gear Sensor Stroke
Sensor
Rotary
Encoder
Linear
Encoder
Torque (Frequency Pulse) to CAN >

For Torque & Flex-Fuel Sensors

Torque Sensor Flex-Fuel Sensor
CAN to Voltage Converters Also Available >

Convert CAN Bus to Voltage or Alarm Signals

Automotive Construction Machinery Agricultural Machinery Office Equipment, etc.

Customization Support [Contact Us Anytime]

 > View Product Lineup 

■ Flexible measurement options and channel configuration ■ Convenient, simple, and cost-effective ■ Modifications available for "Power Supply, Output Voltage, Communication Protocols," etc.
■ Solutions starting from single units ■ Calibrations supported as integrated assemblies ■ Calibration certificates and traceability charts available

Enclosure / Box Mounting

> Details

Multi-CH with Display

> Details

Multi-CH Radiation Pyrometer with CAN Output

> Details

With SD Card Logger

> Details

Rack Integration

> Details

Handheld Type

> Details

Selectable Connectors, Display Options, and Power Inputs

Connectors
Terminal Block
For Thermocouple
Banana Plug
BNC
       
LAN
USB-C
D-sub
HDMI
Display Options
LCD Monitor Without Display External Monitor Display
Monitor display software included
*Monitor not included
Power Supply
AC Power

DC Power

Key Features & Capabilities

Thermal detection and process control for electrical products & mobile devices:
Convert thermistor (temperature) input to CAN for direct data acquisition.
CAN communication dramatically reduces external noise,
while minimizing installation wiring complexity for multi-channel structures.
High-speed CAN bus communication with up to 1 ms refresh rate.
CAN parameters auto-stream data at predefined refresh rates, significantly lowering software development costs *Depending on model
(Non-CAN models utilize standard command-response architecture for data retrieval)

Selection Points

Temperature Capture
Continuous CAN Streaming Function
Streamlined digital data retrieval *Depending on model

Up to 1 ms refresh rate via CAN bus (Optional)

Verified compliance setups for SAE J1939 (DLC up to 8 bytes) *Contact us for advice
Superior Accuracy
Logarithmic Approximation via B2 Constant achieves conversion accuracy within ±0.05%rdg
@ 0°C to 150°C

Resistance Measurement Error: ±0.02% FS @ 23°C

Cost-Effective
Budget-Friendly Edition HTL Series:
CAN Bus Communication with 40 ms refresh rate

Product Lineup

Shared Core Strengths

・Simultaneous output of high-precision 16-bit analog signal and high-speed CAN (1 ms) [Optional]
・Diverse alternative outputs supported: RS-485 / Alarms / Modbus [Optional], USB-C [Standard]
・Advanced HOLD tools (Current / Min / Max / Peak-to-Peak Max), Span/Zero Calibration, and Span/Zero Shift
・Complimentary dedicated configuration software: Supports setup management, report printing, and CSV data logging

HT-24T

> View Product Page

Accessible Single-Channel Type

Analog Output & Digital Comm.
1 ms to 9999 ms variable refresh

Power Input
7 V to 60 V DC / 5 V USB Bus Power

Display: 5-Digit Layout
Green LED layout options available

Dimensions: W48 x H24 x D106 mm

DIN Rail Mounting Supported


HTL-24

> View Product Page

Affordable 1-Channel Budget Edition

Analog Output & Digital Comm.
40 ms to 9999 ms refresh rate

Power Input
7 V to 30 V DC / 5 V USB Bus Power

Display: 5-Digit Layout
Red LED configuration only

Dimensions: W48 x H24 x D106 mm

DIN Rail Mounting Supported



With SD Card Logger

> View Product Page

Store Logged Data to Memory Card

Front-Panel Buttons
Instant Log Start / Stop Control

1-Channel Input Architecture

Power Options:
100 V AC / 8 V to 30 V DC, etc.

Display: 5-Digit Layout

Dimensions: W120 x H48 x D160 mm

Selectable Connectors
BNC, M8, Terminal Blocks, etc.


Multi-CH Thermistor to CAN Converter

> View Product Page

Customizable Channel Counts & Connectors

Multi-CH Input Array [Customized Build]

Power Input:
8 V to 30 V DC

Display Setup
Available with or without display

Dimensions: W126 x H53 x D128 mm

Selectable Connectors
BNC / LAN / D-sub / Terminal Block

Smart Configuration & Logging Manage configurations, print detailed report documentation, and run CSV log data via our complimentary LINKSHIP software.

 > Visit LINKSHIP Software Page 

CSV Data Logging


Log intervals specified by seconds. Custom logging software builds available.

Compare Parameters


Compare and verify multiple parameters across device setup lists.

Save & Copy via PC


Eliminates manual transcription errors; significantly lowers management overhead.

Prevent Misoperation


Configure setups directly on PC monitors to eliminate mistakes from device buttons.

Reduce Setup Hours


Simply clone a master parameter file and flash the data configuration onto multiple units.

Standard USB Type-C Integration: Parameters *HT/HTL-24T models also support active logging and device power supply.

HT / HTL-24T
Customized Build

 
 
PC-Free Handheld Configuration Unit (Sold Separately)

> PL-5A Product Page
※Dedicated for parameter setting only. Does not support data logging or power supply.

Effortless Wiring & Installation

[HT/HTL-24T]

Detachable Plug Connectors
Easy pre-wiring and snap-on hookup

Detachable Plug Connectors
Spring-lock mechanisms


Detachable Plug Connectors
M2 screw-lock mechanisms

Fixed Connectors Also Available
[Custom Support]


Quick body insertion / removal
Mounting Side-Hooks (Left/Right)


Versatile Measurement Configurations

Portable Field Measurements


Take your PC, tablet, converter unit, and cables on-site for immediate measurement via USB bus power*. Optional carrying case BXS-1 available.
*For Load Cell / Pressure Sensor ST(L) lines, supply power through the rear terminal block rather than the USB port.



> BXS-1 Overview

 

Panel Integration


Ultra-compact 24x48 mm form factor optimizes panel space efficiency.


> 24x48 mm Dimension Diagrams

 

DIN Rail Mounting


One-touch installation fixtures and display-free designs are available to suit your system.

BXF-DN2
DIN Rail Mounting Fixture (Sold Separately)
Type 2451
Without Display
Type 2431
With Display
> BXF-DN2 Page > View 2451 / 2431 Specifications
 > Contact us