Production Line / Machinery
![]() ![]() ![]() |
Non-Contact Measurement | 12x Infrared Pyrometers * | |||||||
| ・・・・ | ![]() |
Measurement Signal ![]() Sensor Power Supply ![]() |
|||||||
| ・・・・ | ![]() |
Measurement Signal ![]() Sensor Power Supply ![]() |
|||||||
| ・・・・ | ![]() |
Measurement Signal ![]() Sensor Power Supply ![]() |
|||||||
| ・・・・ | ![]() |
Measurement Signal ![]() Sensor Power Supply ![]() |
|||||||
| ・・・・ | ![]() |
Measurement Signal ![]() Sensor Power Supply ![]() |
|||||||
| ・・・・ | ![]() |
Measurement Signal ![]() Sensor Power Supply ![]() |
|||||||
| ・・・・ | ![]() |
Measurement Signal ![]() Sensor Power Supply ![]() |
|||||||
| ・・・・ | ![]() |
Measurement Signal ![]() Sensor Power Supply ![]() |
|||||||
| ・・・・ | ![]() |
Measurement Signal ![]() Sensor Power Supply ![]() |
|||||||
| ・・・・ | ![]() |
Measurement Signal ![]() Sensor Power Supply ![]() |
|||||||
| ・・・・ | ![]() |
Measurement Signal ![]() Sensor Power Supply ![]() |
|||||||
| ・・・・ | ![]() |
Measurement Signal ![]() Sensor Power Supply ![]() |
|||||||
*Infrared temperature sensors are not included with this instrument.
|
12-Channel Thermometer
|
CAN Output ![]() Analog RS-485 Ethernet HDMI Alarm Output also available |
CAN Bus Output
|
||||||
![]() CAN-to-USB Data Logger, etc. |
||||||
![]() USB Link |
Direct data transmissions streaming to PC via CAN-to-USB loggers are fully supported. | |||||
![]() PC Node / System |
||||||
Inputs other than infrared pyrometers can also be engineered to specification.
Select only your required functions for I/O configurations, channel scaling, connectors, power supplies, or mounting handles—achieving smart, simple, and cost-efficient integration.| Thermocouple > | |||
Compatible with Types K, J, R, E, T, B, N, S
|
| Thermistor > |
High-precision math processing algorithms ![]() NTC Thermistors |
| RTD > | ||
Supports Pt100 RTD sensor elements
|
| Load Cell / Pressure / Strain > | ||||||||
Excitation: 2.5V/5V/10V | Bridge: 120Ω/350Ω
|
| Current > | ||||||||
Supports arrays from ±100μA to ±10A
|
| Voltage > | ||||||||
Supports scales from ±10mV to ±70V
|
| Resistance > | ||||
For displacement and resistive sensors
|
| Speed Pulse Input > | ||||||||
High precision via Periomatic
|
| Totalizing Pulse Input > | ||||||||
Distance, Angle, Displacement, Flow, etc.
|
| Torque Pulse Input > | ||||
For torque sensors and fuel-mix arrays
|
| CAN Converter > | ||||||||
Convert CAN bus data to analog or alarms
|
|
and more | ||
|
|
||
|
|
||
|
are also supported |
![]() |
|
![]() |
|||
|
|
|
|||
![]() |
![]() |
||||
|
|
Output to various devices is supported.
![]() |
![]() |
![]() |
|||
|
|
|
|||
![]() |
![]() |
![]() |
|||
|
|
|
|||
![]() |
![]() |
||||
|
|
| AC |
| DC |
| With/Without Power Switch |
![]() |
![]() |
![]() |
![]() |
| With/Without Handle |
| Rack Mounting, etc. |


CAN communication parameters and other settings can also be configured via PC.
Selectable from 0-10V, 0-5V, ±10V, ±5V, or 4-20mA at the time of order.
Resolution of 50,000 or higher, full/zero scale setting, and analog output zero adjustment.
Output and display data on your own monitor. Custom display software is also available. *Monitor is not included.
| > About LINKSHIP |
| View more > |
| Load cell/Pressure/Strain | CAN to analog |
| DC current | DC voltage |
| Thermocouple meter | Thermistor meter |
| RTD meter | Resistance Meter |
| Speed/Count, Pulse Freq. | Torque/Freq.deviation |
Various Outputs
Software LINKSHIP
For data logging, setting
Customization
| > View List |
> Details

> Details

> Details


> Details

> Details

> Details