Applications

Incorporation into burn-in test equipment

- Burn-in tests evaluate the durability of electronic components by applying temperature and voltage loads to them to reduce initial defects and accelerate degradation before shipment.
- There are different types of burn-in tests such as dynamic burn-in, monitored burn-in, static burn-in, etc., depending on the purpose.。

Temperature
Pressure
Current
Thermostatic bath
Temperature
Voltage
Current
Resistance
Frequency
HT
PSV
PSA
RR
SPD

CAN
USB
Analog Output
RS-485
→→→→→→

PC
Oscilloscope
Data logger
Signal input
Characteristic
measurement

Good/Fail judgment
Alarm Output
→→→→→→

PLC

What you can do with the measurement
- Built-in to burn-in test equipment to measure temperature (HT, HT-R series), voltage (PSV series), current (PSA series), and other characteristic tests.
- CAN 1ms~ update and 16bit analog 0.1ms~ update can be output simultaneously (option).
- COCORESEARCHh's measurement management software LINKSHIP (free of charge)
Configuration and logging are available through the USB Type-C connector on the main unit of the instrument.

Selection Points
Thermocouple measurement
 16bit analog output with 2ms update and CAN communication (option)
  
RTD ResistanceThermocouple measurement
Voltage measurement
Current measurement
Resistance measurement

 16bit analog output with 1ms update and CAN communication (option)

Speed (frequency) measurement
 16bit analog output with 0.1ms update, CAN communication with 1ms update (option)

Low Price
 HTL-2401, HTL-2401R, PSVL-2401, PSAL-2401, RRL-2401, SPDL-2401: Low cost instruments.
 High-precision (16bit update time from 40 ms) analog output and CAN communication are available as options.

Products
Series Name EX48 [48x96 size] EX24 [24x48 size] EXL24 [24x48 size]  
  Common Features

USB RS-485 Modbus CAN
Analog output Alarm output
LINKSHIP compatible

Thermistor meter Under Development
HT-24T
HTL-24T
High conversion accuracy with unique calculation method
RTD meter
HT-48R
HT-24R
HTL-24R
Combines with Pt100 to measure temperature
Thermocouple meter
HT-48
HT-24
HTL-24
Compatible with TC types K. J, R, E, T, B. N
DC Ammeter
PSA-48
PSA-24
PSAL-24
±10A to ±100μA: Shunt resistance of 40mΩ or less (±5A, ±2A type) for low loss.
DC Voltmeter
PSV-48
PSV-24
PSVL-24
±70V to ±10mV: For real-time measurement and feedback control.
Resistance Meter
RR-48
RR-24
RRL-24
4 ranges (150Ω/1.5kΩ/10kΩ/40kΩ) switchable by setting.
Speed (frequency) meter
SPD-48
SPD-24
SPDL-24
PERIOMATIC™ calculation for High accuracy and High speed response
Output Update Time* 0.1ms/1ms/2ms- 0.1ms/1ms/2ms- 40ms- *Varies depending on model