- Burn-in tests evaluate the durability of electronic components by applying temperature and voltage loads to them to reduce initial defects and accelerate degradation before shipment.
- There are different types of burn-in tests such as dynamic burn-in, monitored burn-in, static burn-in, etc., depending on the purpose.。
Temperature Pressure Current |
→ | Thermostatic bath |
Temperature Voltage Current Resistance Frequency |
HT PSV PSA RR SPD |
CAN |
PC | |
→ | Oscilloscope Data logger |
||||||
Signal input | → | Characteristic measurement |
Good/Fail judgment |
PLC |
What you can do with the measurement
- Built-in to burn-in test equipment to measure temperature (HT, HT-R series), voltage (PSV series), current (PSA series), and other characteristic tests.
- CAN 1ms~ update and 16bit analog 0.1ms~ update can be output simultaneously (option).
- COCORESEARCHh's measurement management software LINKSHIP (free of charge)
Configuration and logging are available through the USB Type-C connector on the main unit of the instrument.
Selection Points
Thermocouple measurement
16bit analog output with 2ms update and CAN communication (option)
RTD ResistanceThermocouple measurement
Voltage measurement
Current measurement
Resistance measurement
16bit analog output with 1ms update and CAN communication (option)
Speed (frequency) measurement
16bit analog output with 0.1ms update, CAN communication with 1ms update (option)
Low Price
HTL-2401, HTL-2401R, PSVL-2401, PSAL-2401, RRL-2401, SPDL-2401: Low cost instruments.
High-precision (16bit update time from 40 ms) analog output and CAN communication are available as options.
Series Name | EX48 [48x96 size] | EX24 [24x48 size] | EXL24 [24x48 size] | ||||
Common Features USB RS-485 Modbus CAN |
|||||||
Thermistor meter | Under Development |
|
|
High conversion accuracy with unique calculation method | |||
RTD meter |
|
|
|
Combines with Pt100 to measure temperature | |||
Thermocouple meter |
|
|
|
Compatible with TC types K. J, R, E, T, B. N | |||
DC Ammeter |
|
|
|
±10A to ±100μA: Shunt resistance of 40mΩ or less (±5A, ±2A type) for low loss. | |||
DC Voltmeter |
|
|
|
±70V to ±10mV: For real-time measurement and feedback control. | |||
Resistance Meter |
|
|
|
4 ranges (150Ω/1.5kΩ/10kΩ/40kΩ) switchable by setting. | |||
Speed (frequency) meter |
|
|
|
PERIOMATIC™ calculation for High accuracy and High speed response | |||
Output Update Time* | 0.1ms/1ms/2ms- | 0.1ms/1ms/2ms- | 40ms- | *Varies depending on model |