Thermocouple meter HT-2401
Digital Panel Meters for Temperature Measurement, Thermocouple Temperature Converters, Indicating Alarm Meters

Option
Dimensions
Applications
Software

Compatible with various thermocouple[TC] types K, J, R, E, T, B, N, S

- Select a TC type and measure the temperature.
- The electromotive force corresponding to the temperature difference between the tip of the TC and the main body of the instrument is measured as a voltage and converted to a temperature.

Measurement: -270°C to +1820°C
Measurement Resolution: 0.1°C / 1°C
Rate setting between two points Linear Compensation Formula

Usage example *The figure below includes optional functions

Input
Thermocouple
K, J, R, E, T, B, N, S
 
Calculation
・Moving average Max. 99
・HOLD [Current value/Max. value/Min. value/Max. variation range]
Zero shift
HT-24 series
Power supply
・7 to 60V DC
・USB power 5V
Setting
・LINKSHIP software
・Setting unit PL-5A
   
Output
16bit analog
CAN
RS-485
Alarm
Modbus*
USB
*In preparation
PC, PLC, Logger, Oscilloscope, Indicators, etc.

     

Body Type

HT-2401

Front USB


HT-2411

Rear USB, Front waterproof gasket included


HT-2431

DIN rail mounting, with indicator


HT-2451

DIN rail mounting, no indicator


Customization [Minimum of 1 unit: Please consult with us]

 >View more 

■Select and combine only what you need
■Convenient, easy, and low cost
■Functional change : power supply, output voltage, communication specifications, etc.
■Calibration as an embedded product is available
■Calibration documents and traceability charts can be issued

Compact multi-CH
Flexible number of CHs

Boxed type
Easy to use and low cost

With SD logger
Logging data storage

Multi-CH CAN output
20CH, with display

Rack Mounted, Control Box

HDMI output, multi-CH

Output 2ms update

 See 40ms type> 

CAN [Option]]

3-wire wiring greatly reduces wiring compared to BCD
Powerful error detection system for improved noise immunity and safety

SAE J1939 [DLC 8 bytes or less] Customization experience available
Please contact us for other customizations.

RS-485 [Option]

16bit analog [Option]
Resolution 50,000 or more/Full scale and zero scale settings, output zero adjustment


Alarm [Option] 1 to 4points [Depends on model]


USB Type-C [Standard feature] Data logging, setting


Reasonable and easy-to-use 1CH type

 See Low-cost version > 
HT-2401
32,500 yen and up*
Display only, Equipped with USB communication
HT-2451
28,100 yen and up*
DIN rail mounting, no display
*Prices as of February 2024, in Japan. Tax not included
 See options and price list> 

Smart configuration and logging

Setting management, report printing, and CSV logging with dedicated software LINKSHIP [free of charge]

 LINKSHIP Page > 

CSV logging



Time-specific logging available. Custom logger software is available.

Compare set value lists



Multiple lists of set values can be compared and collated.

Save and copy of set



Prevents errors in handwriting and typing, and reduces management time and costs.

Prevention of misoperation



Settings and confirmations can be made on the PC screen, preventing misoperation of the main unit's buttons.

Quickly set up multiple units



Even multiple units can be easily configured by simply writing the configuration data.

USB Type-C connector standard:For setting / logging / power supply


Setup unit without LINKSHIP or PC required [Sold separately]



>PL-5A Product Page
*Setting only / data logging and power supply not available

Easy wiring and installation For on-site usability

Detachable Plug Connectors
Simply connect the wires to the connector and plug it in by hand.

Detachable Plug Connectors
Spring lock type [Standard]


Detachable Plug Connectors
M2 screw type [Option]

Fixed Connector
Non-detachable [Customize]


Mounting hooks
Fixing the main body


*Not included in 2431 and 2451 types

Various ways to use

Carry and measure

Carry PC, instrument, and cable, and measure with USB power supply. Storage case BXS-1 is also available.



>BXS-1 Overview

Built in panel

24x48 size contributes to downsizing


>HT-24 Dimensions

DIN rail mounting

One-touch fixture and display-less type

BXF-DN2
DIN rail attachment [sold separately]
HT-2451
Display-less type
HT-2431
With display type
>BXF-DN2 page

Power supply 7 to 60V DC, and 5V USB power supply

Isolation Electrical isolation between power supply/ Thermocouple input/other inputs and outputs

Applications

 Applications list > 


Incorporation into burn-in test equipment


Thermocouple to CAN conversion


For Infrared Temperature Sensors, Multi-CH Thermometer


Wind Tunnel Testing / vehicles, motorcycles, architectural and civil engineering structures, etc.

 Model List, Options and Prices > 

 
Name Thermocouple meter
Model HT-2401 / HT-2411 / HT-2431 / HT-2451
Input
Number of input 1 point Thermocouple
Measuring range
TC types Range A(0.1℃) Range B(1℃) Accuracy*
K -170.0 to 1370.0 °C -250 to 1370 °C (±0.5%FS)
J -200.0 to 1100.0 °C -200 to 1100 °C (±0.5%FS)
R 100.0 to 1760.0 °C -50 to 1760 °C (±0.5%FS)
E -140.0 to 1000.0 °C -260 to 1000 °C (±0.5%FS)
T -240.0 to 400.0 °C -270 to 400 °C (±0.5%FS)
B 480.0 to 1820.0 °C 100 to 1820 °C (±0.5%FS)
N 580.0 to 940.0 °C -220 to 1300 °C (±0.5%FS)
S 450.0 to 1760.0 °C 50 to 1760 °C (±0.5%FS)
*Accuracy is specified by setting output update time of 100 ms.
*Measurements can be made with a resolution of 0.1°C within the measurement range.
Cold junction compensator accuracy ±2℃
Measurement resolution Measurement range A: 0.1°C / B: 1°C
Burnout display "bAhn" in 7seg characters
Input connector Plug type [Standard] Spring lock / [Option] M2 screw
Calibration Adjustable with zero reference voltage input and span reference voltage input for each thermocouple type
(Adjustment command via CAN or USB command)
   
Calculation
Moving Average Number 1 to 99
Control input None or 1 point (depending on model)   [D2] Option adds 2 points
[Settings] Set functions per control input (CTL) for external control
[Functions] Hold (current value, max value, min value, max fluctuation range),
zero shift
[Operation] Control Input (CTL*) Terminal (ON Logic):
Short to GND (Open) for ON, Open (Short) for setting content to take effect
[Commnication] Command control possible via communication (USB, CAN, RS-485)
*Commands set via communication cannot be canceled by terminal input. Reset execution is always required
Setting Value Memory Non-volatile Memory (EEPROM)
   
Display
Display Color [Standard] HT-2401 Red LED
[Option]HT-2401-G Green LED
Indicator [Numerical Display] 5-digit, 7-segment LED Character height 9mm
Display range:-19999 to 99999
Over indication: OL / Zero indication: Leading zero suppress
Decimal point position Semi-fixed Set in program mode. [0] *****,  [1] ****.* to [4] *.****
Display update time 0.3 sec [settable from 0.1 to 9.9 sec]
Display accuracy 20ppm ± 1 digit
Display Moving Average 1 to 9
Indicator LED 1 point [selected from power/ control input]
 
USB communication
Specification USB2.0 [Serial port communication by USB virtual COM 230.4kbps]
Function Writing/reading of set values/ Continuous output of measured values
Output update 2 to 9999ms, settable in 2ms increments
 
General Information
Operating temp./humidity -10°C to +50°C / 35 to 85%RH [non-condensing]
Power supply 7 to 60V DC with reverse connection protection. Power supply from USB host: 5V
Power consumption 3W or less
Isolation Power supply / TC input / Other input/output
Withstand voltage Between each terminal of the above isolation:
DC 500V for 1 minute
Weight Approx. 60g
 
CAN Option
Specifications CAN2.0B 10 k / 20 k / 50 k / 100 k / 250 k / 500 k / 1M bps [Format] INTEL/MOTOROLA, [Frame] 11bit/29bit
Function Writing/reading of set values/ Continuous output of measured values
Setting item CAN transmit ID, CAN receive ID
Output update 2ms to 9999ms  settable in 2 ms increments
 
RS-485 communication option Modbus RTU support is available upon request.
Connected units 32 units [max.]
Format 2-wire multi-drop serial communication
Method Asynchronous
Standard RS-485
Speed 9600bps / 19200bps / 38400bps Set in program mode
Data format Start bit: 1 bit / Stop bit: 1 bit / Data length: 8 bits / Parity bit: None
Code ASCII
Function Writing/reading set values/measurement value output [response to request command]
 
Analog output option
Output signals [E1] 0 - 10V [E5] 0 - 5V [R1] ±10V [R5] ±5V [I1] 4 - 20mA  [Select a model]
D/A conversion DAC conversion method
Output resolution 16bit [50,000 or more]
Load resistance [Voltage output] 4.7kΩ or more / [Current output] 300Ω or less
Output accuracy [Voltage output] ±0.1% of FS @ 23℃/ [Current output] ±0.1% of FS @ 23℃
Temp. fluctuation ±200ppm/℃ or less
Output scaling Arbitrary scaling is possible by full scale and zero scale settings
Output update 2 to 9999ms settable in 2ms increments
Input/output delay Output update time + analog rise time 150 μs max.
 
Alarm [Comparator] output option
Setting method Set in program mode
Number of outputs 2 points (or 1 point) depends on the models  1 point for line driver input and analog output with comparator output specification.
Output form Isolated non-contact output [photo-MOS relay] No polarity.
When comparator operating condition is ON, resistance between COMP and COM
50 Ω or less
Output load voltage Peak AC/DC280V 100mA [resistive load] / ON resistance 50Ω or less
Output logic Comparison is made with polarity [0 is greater than minus]
[Over] ON when set value or more
[Under] ON when set value or less
[Within range] ON within the set value, OFF outside the range
[Out of range] ON outside the set value, OFF within the range
Update time Depends on analog output update time setting. Response time 1ms [max.]

Related Products

All products> Temperature meters>

Other measurement categories:EX Series

 View List > 
Input type
Load cell/Pressure/Strain CAN to analog
DC current DC voltage
Thermocouple meter Thermistor meter
RTD meter Resistance Meter
Speed/Count, Pulse Freq. Torque/Freq.deviation

CAN, 16bit analog, Alarm, RS-485, Modbus

 Various Outputs

Smart configuration / Prevents unintentional operation

 Software LINKSHIP

USB Type-C standard equipment

 For data logging, setting

Built in box, multi-CH, and function changes, etc

 Customization


EX48


EX(L)24