Configurable reference distance and time units relative to input frequency (Speed mode only: sec/min/hour/day)
Control Input Functions
Reset, Start Measurement (Falling edge)
Control Input Operation
Settings are applied when the control input terminal is shorted to GND
Display Section
Numerical Display
6-digit, 7-segment Red LED (Character height: 14.2mm)
Display Range
-199999 to 999999 | Polarity: "-" illuminates during reverse rotation
Overflow Indicator: "OL" Zero Blanking: Leading zero suppression
Display Update Rate
0.3 seconds (Configurable within 0.1 to 9.9s range)
Decimal Point Position
Selectable via program mode (0: □□□□□□ to 4: □□.□□□□)
Measurement Accuracy
Time Quantization Error: 20.8ns + 25ppm ±1 digit
Status Indicators (4x Circular LEDs)
[IN] Edge Detection Status
- 1-Sensor (Rising): On at Low / Off at High
- 1-Sensor (Falling): Off at Low / On at High
- 2-Sensor (Rising): On at Low
- 2-Sensor (Falling): On at High
[RUN] Illuminates during standby for signal input after reset
USB Communication Section
Interface
USB 2.0 (Serial communication via Virtual COM port, 230.4kbps)
Functions
Reading and writing configuration values
General Specifications
Operating Temp/Humidity
-10°C to +50°C | 35% to 85% RH (Non-condensing)
Power Supply Voltage
[AF Type] AC 100-240V (Maximum rating: AC 85-264V, 50/60Hz)
Power Consumption
3W max.
Galvanic Isolation
Between power supply and all other input/output terminals
Dielectric Strength
Between power supply and all other I/O terminals: DC 500V for 1 minute
Weight
Approx. 340g
For CAN, RS-485 communication, analog output, and alarm outputs, please contact us.
- CAN & 16-bit Analog (Voltage/Current) Output Available
- USB Type-C: Setup Configuration & Data Logging
- Alarm Outputs / RS-485 Communication
- Free Dedicated Software: Configuration Management, Report Printing, and Data Logging