COCORESEARCH Measuring Instrument Manufacturer
Products
Applications
Technical Info
Support
Company
Careers
Inquiry
PAGE
TOP

RTD Thermometers Product List
Panel Meters & Signal Converters for Temperature Measurement

Pt100 RTD Compatible With Pt100 Resistance Check Function

Measures temperature in combination with Pt100 sensors.

Input
Various RTD Sensors
Pt100
 
Calculation
・Moving Average: Max 99 ・Zero Shift
・HOLD [Current / Max / Min / Peak-to-Peak Max]
RTD Thermometer
   
Output
・16-bit Analog ・Alarm
・CAN ・RS-485 ・Modbus ・USB
PC, PLC, Logger, Oscilloscope, Indicator Lights, etc.

Applications

 View Applications List > 

Convert RTD to CAN

 > Details 


Measurement of Temperature, Torque, Speed, and Position of Rotating Bodies via Slip Ring

 > Details 


Simultaneous Temperature Measurement for Multiple Points: Inside Tanks, Piping, Chambers, Facilities, Food, Liquids, Ambient/Room Temperature, etc.

 > Details 

Features

Measurement Range: -200°C to +850°C

Accuracy: ±0.2% of FS

2-Point Rate Setting (Linear Approximation Formula)

With Pt100 Resistance Check Function

CAN Output of Measured Values [Option]
CAN Continuous Output Function: Easily retrieve measured values as digital values

Output Update Rate: Up to 1ms update

Proven track record with SAE J1939 (DLC 8 bytes or less), etc. *Please consult us
16-bit Analog Output [Option]

Up to 1ms output update rate *40ms for HTL

0-10V
0-5V
±10V
±5V
4-20mA
*Select from the above 5 types when ordering
Alarm Output [Option]
Hi-Limit
Lo-Limit
In-Range
Out-Range

USB Type-C [Standard]

Data Logging & Settings Configuration
*HT(L)-24 also supports power supply

RS-485 [Option]

Modbus RTU [In Preparation]

Lineup

 > Details 

HT-4801R

48x96mm Size

Analog Output & Digital Communication
1-9999ms update rate

Power Supply
100-240 VAC / 9.6-30 VDC

Display: 6 Digits
Green LED model also available

Dimensions: W96, H48, D99 mm

Front Configuration Buttons

 > Details 

HT-24R

24x48mm Size

Analog Output & Digital Communication
1-9999ms update rate

Power Supply
7-60 VDC / 5V USB Power Supply

Display: 5 Digits
Green LED model also available

Dimensions: W48, H24, D106 mm
24x48 DIN Size

DIN Rail Mounting Support

 > Details 

HTL-24R

24x48mm Size / Low-Cost Model

Analog Output & Digital Communication
40-9999ms update rate

Power Supply
7-30 VDC / 5V USB Power Supply

Display: 5 Digits
Red LED only

Dimensions: W48, H24, D106 mm
24x48 DIN Size

DIN Rail Mounting Support



 > Details 

With SD Logger

Save logging data directly to card

Front Buttons
Start / Stop Logging

1-CH Input

Output
CAN
16-bit Analog (Voltage/Current)
Alarm
Ethernet
HDMI

Power Supply
100 VAC / 8-30 VDC, etc.
Selectable Connectors
BNC / M8 / Terminal Block, etc.


 > Details 

Compact Multi-CH

Lightweight and ideal for automotive use

Multi-CH Input Custom product

Output
CAN
16-bit Analog (Voltage/Current)
Alarm
Ethernet
HDMI

Power Supply 8-30 VDC
Display Selectable (With/Without)
Selectable Connectors
BNC / LAN / D-sub / Terminal Block

Customization Available [Please consult us]

 >View List 
Flexible Measurement Types & CH Count

Available from Single Units
Convenient, Easy & Low Cost

Calibratable as an Embedded Unit
Spec Modifications: Power, Output Voltage, Communication, etc.

Calibration Docs & Traceability Charts Available

Customization Examples [Available for Purchase]

Enclosure Case Box

 > Details 

Multi-CH with Display

 > Details 

Multi-CH Infrared Thermometer CAN Output

 > Details 

With SD Logger

 > Details 

Rack Mount Assembly

 > Details 

Handy Portable Type

 > Details 

Selectable Connectors, Displays, Power Supplies, etc.

Connectors
Terminal Block
Thermocouple
Banana Plug
BNC
       
LAN
USB-C
D-sub
HDMI
Display
LCD Monitor Without Display External Monitor
Free viewer software included
**Monitor not included
Power Supply
AC

DC

Smart Configuration & Logging Manage settings, print reports, and perform CSV data logging with free LINKSHIP software

 > Go to LINKSHIP Page 

CSV Data Logging


Log at specified intervals (seconds). Logger software customization also available.

Compare Settings


Compare and verify multiple configuration parameter lists.

PC Backup & Copy


Prevent manual typing errors, reducing management overhead and costs.

Prevent Misoperation


Configure and verify settings via PC screen to avoid hardware button errors.

Reduce Setup Hours


Simply copy the master configuration and write data to multiple units.

Standard USB Type-C: Configuration *HT/HTL-24R also supports data logging & USB power supply

HT/HTL-24R
HT-48R
Customized Products


Handy External Programmer (No PC Required) (Sold Separately)

> PL-5A Product Page
*For configuration only. Data logging and power supply functions are not supported.

Easy Wiring & Installation

[HT/HTL-24R]

Detachable Plug Connectors
Wire to connector for easy attach/detach

Detachable Plug Connectors
Spring-lock Type


Detachable Plug Connectors
M2 Screw Type

Fixed-type Connectors Also Available
[Custom Support]


Easy Unit Attach/Detach
Mounting Hooks (Left/Right)


Versatile Use Cases

[HT/HTL-24R]

Portable Measurement

Carry PCs, tablets, units, and cables for USB-powered field measurements. BXS-1 carrying case (sold separately) is available.



> BXS-1 Overview

Panel Integration

Contributes to downsizing with its 24x48mm size.


> HT-24R Dimensional Drawing

DIN Rail Mounting

One-touch mounting brackets and models without display are available.

BXF-DN2
DIN Rail Bracket (Sold Separately)
HT-2451R
Without Display
HT-2431R
With Display
> BXF-DN2 Page > View Description for 2451 & 2431

Specification Example

Name RTD (Pt100) Thermometer
Model HT-2401R / HT-2411R / HT-2431R / HT-2451R
Input Section
Input Channels 1-CH, Pt100 RTD (3-wire system)
Measuring Range -200°C to 850°C, ±0.2% of FS
Resistance Check Function 0 to 400 Ω
Calculation Section
Moving Average Count 1 to 99 (Display moving average count: 1 to 9)
Control Input None, or 1 point (depending on model) / 2 points added with [D2] option
(Configurations) Set functions for each control input (CTL) and control externally.
[Functions] Selectable from Hold (Current value, Max, Min, Max Peak-to-Peak) and Zero Shift.
(Operation Method) The configuration takes effect when the control input (CTL*) terminal (ON logic) is short-circuited (opened) to GND, and turns ON.
(Data Communication) Command control available via communication (USB, CAN, RS-485). *Commands set via communication cannot be canceled via terminal inputs. A system reset must be executed.
Settings Memory Non-volatile memory (EEPROM)
Display Section
Display (Numeric) 5 Digits, 7-Segment LED, Character Height: 9mm. HT-2401R: Red LED / HT-2401R-G: Green LED (Option).
Display Range: -19999 to 99999 / Over-range Display: OL / Zero Display: Leading Zero Suppression
Display Update Time: 0.3 sec (Configurable within 0.1 to 9.9 sec range) / Display Moving Average: 1 time (Configurable from 1 to 9 times)
Decimal Point Position Semi-fixed, configured in program mode. 0: □□□□□, 1: □□□□.□ to 4: □.□□□□
Display (Indicator) 1 LED, configurable from Power Supply / Control Input.
USB Communication Section
USB Specs USB 2.0 (Serial port communication via USB Virtual COM, 230.4kbps)
USB Functions Read/Write settings parameters, Continuous measured value output
Output Update Time 1ms to 9999ms, configurable in 1ms increments
General Specifications
Operating Temp/Humidity -10°C to +50°C, 35 to 85% RH (Non-condensing)
Power Supply Voltage 7 to 60 VDC (With reverse connection protection) / Powered from USB host: 5V
Power Consumption 3W or less
Isolation Between Power Supply / RTD Input / Other I/Os
Withstand Voltage Between Power Supply / RTD Input / Other I/Os: 500 VDC for 1 minute between each terminal
Weight Approx. 60g
CAN Option
Communication Specs CAN 2.0B (10 k / 20 k / 50 k / 100 k / 250 k / 500 k / 1M bps), Format (INTEL/MOTOROLA), Frame (11-bit / 29-bit)
Communication Functions Read/Write settings parameters, Continuous measured value output
Configurable Items CAN Tx ID, CAN Rx ID
Output Update Time 1ms to 9999ms, configurable in 1ms increments
RS-485 Option Please consult us for Modbus RTU compatibility
Max Connections 32 units (max)
Communication Format 2-wire multi-drop serial communication
Transmission Mode Asynchronous
Communication Specs RS-485
Baud Rate 9600bps / 19200bps / 38400bps, configured in program mode
Data Format Start bit: 1 bit / Stop bit: 1 bit / Data length: 8 bits / Parity: None
Communication Code ASCII
Communication Functions Read/Write settings parameters, Measured value output (Responds to request commands)
Analog Output Option
Output Signal [E1] 0-10V, [E5] 0-5V, [R1] ±10V, [R5] ±5V, [I1] 4-20mA 【Select Model When Ordering】
D/A Conversion Mode DAC conversion mode
Output Resolution 16-bit (50,000 or higher)
Load Resistance Voltage Output: 4.7 kΩ or more / Current Output: 300 Ω or less
Output Accuracy Voltage Output: ±0.1% of FS @ 23°C / Current Output: ±0.1% of FS @ 23°C
Temperature Drift ±200ppm/°C or less
Output Scaling Arbitrary scaling available via full-scale and zero-scale configurations
Output Update Time 1ms to 9999ms, configurable in 1ms increments
Output Response Time 1ms or less (0 to 90% response)
Comparator (Alarm) Output Option
Configuration Method Configured in program mode
Output Points 2 points / 4 points (depending on model selection conditions)
Output Form Isolated solid-state output (PhotoMOS relay), non-polarized. When comparator operation condition is ON, resistance between COMP and COM is 50 Ω or less.
Output Load Voltage Peak AC/DC 280V, 100mA (Resistive load), Max ON-resistance: 50 Ω or less
Output Logic Comparison is performed with polarity (0 is greater than minus)
[High Alert] ON when value is greater than or equal to the set value
[Low Alert] ON when value is less than or equal to the set value
[In-Range] ON within the range, OFF out of the range
[Out-Range] ON out of the range, ON within the range
Update Time Depends on the Analog Output Update Time settings. Response time: 1ms (max)

Other Related Products Panel Meters / Signal Converters / Indicators

Product List > 
EX Series Series List > 

- CAN Output
- 16-bit Analog (Voltage / Current) Output
- USB-C: Configuration & Data Logging
- Alarm Output / RS-485
- Configuration Management Software (Free): Report Printing & Data Logging
- Dual Analog Outputs [EX48]
- Ethernet (LAN) [EX48]

Load Cell / Pressure / Strain
CAN Conversion
DC Current
DC Voltage
Thermocouple (Temp)
Thermistor (Temp)
RTD (Temp)
Resistance
Speed / Totalizer
Freq Deviation / Torque

EX48

EX(L)24
 > Inquiry Form