Coco Research - Measuring Instrument Manufacturer
Products
Applications
Technical Info
Support
Company
Careers
Contact
JAPANESE
PAGE
TOP

Thermocouple Meters Lineup
Digital Panel Meters for Temperature Measurement, Thermocouple Temperature Converters, Thermocouple Converters, Indicator Alarms

Compatible with Various Thermocouple Types K, J, R, E, T, B, N, S

Measures temperature based on the selected thermocouple type.
It reads the electromotive force corresponding to the temperature difference between the thermocouple tip and the instrument body, converting it mathematically into a temperature value.

Input
Various Thermocouples
K, J, R, E, T, B, N, S
 
Calculation
・Moving average (Max 99)
・HOLD [Current / Max / Min / Peak-to-Peak Max]
・Zero shift
Thermocouple Meter
   
Output
・16-bit analog ・Alarm
・CAN ・RS-485 ・Modbus ・USB
PC, PLC, Logger, Oscilloscope, Indicator lights, etc.

Application Examples

 View All Application Examples > 

Non-contact, multi-point temperature measurement for production lines: Radiation temperature sensors & CAN

 > Read More 


Temperature measurement in wind tunnel experiments: Vehicles, architectural and civil engineering structures, etc.

 > Read More 


Converting thermocouple signals to CAN

 > Read More 


Integration into burn-in testing equipment

 > Read More 


Fluid temperature difference measurement for flow rate error correction

 > Read More 

Features

Supports thermocouple types K, J, R, E, T, B, N, and S via setting switch

Measurement Range
-270°C to +1820°C

Measurement Resolution
0.1°C / 1°C

Two-point scaling setup
(Linear approximation formula)

CAN Output of Measured Values [Optional]
Continuous CAN Output Function: Easily acquire measured values as digital data

Output Update Rate: Up to 1 ms updates

Proven implementations include SAE J1939 (DLC 8 bytes or less), etc. *Please consult us
16-bit Analog Output [Optional]

Up to 1 ms output update rate *40 ms for HTL

0-10V
0-5V
±10V
±5V
4-20mA
*Select from the 5 types above at the time of order
Alarm Output [Optional]
Upper Limit
Lower Limit
In-range
Out-of-range

USB Type-C [Standard]

Data logging and configuration
*Bus power support available for HT(L)-24

RS-485 [Optional]

Modbus RTU [Under Development]

Product Lineup

 > Details 

HT-4801

48x96 mm size

Analog Output / Digital Communication
1-9999 ms update rate

Power Supply
100-240 VAC / 9.6-30 VDC

Display 6 digits
Green LED type also available

Dimensions W96, H48, D99 mm

Front configuration buttons

 > Details 

HT-24

24x48 mm size

Analog Output / Digital Communication
2-9999 ms update rate

Power Supply
7-60 VDC / 5 V USB bus power

Display 5 digits
Green LED type also available

Dimensions W48, H24, D106 mm
24x48 DIN size

DIN rail mounting support

 > Details 

HTL-24

24x48 mm size / Low-cost version

Analog Output / Digital Communication
40-9999 ms update rate

Power Supply
7-30 VDC / 5 V USB bus power

Display 5 digits
Red LED only

Dimensions W48, H24, D106 mm
24x48 DIN size

DIN rail mounting support



 > Details 

With SD Logger

Saves logging data to SD card

Front Buttons
Start / Stop logging

1-Channel Input

Output
CAN
16-bit analog (Voltage/Current)
Alarm
Ethernet
HDMI

Power Supply
100 VAC / 8-30 VDC, etc.
Selectable Connectors
BNC / M8 / Terminal block, etc.


 > Details 

Compact Multi-Channel

Lightweight, ideal for in-vehicle use

Multi-Channel Input Custom product

Output
CAN
16-bit analog (Voltage/Current)
Alarm
Ethernet
HDMI

Power Supply 8-30 VDC
Display With / Without display selectable
Selectable Connectors
BNC / LAN / D-sub / Terminal block

Customization Available [Please consult us]

 > View List 
Flexible Measurement Types & Channels

Available from Single Units
Convenient, Easy, and Cost-Effective

Calibratable as an Embedded Module
Spec Modifications: Power, Output, Communication, etc.

Calibration Docs & Traceability Charts Issuable

Customization Examples [Available for Purchase]

Enclosure Box Type

 > Details 

Multi-CH with Display

 > Details 

Multi-CH Radiation Thermometer (CAN Output)

 > Details 

With SD Logger

 > Details 

Rack Mount

 > Details 

Handy Type

 > Details 

Selectable Connectors, Display Options, Power Supplies, etc.

Connectors
Terminal Block
Thermocouple
Banana Type
BNC
       
LAN
USB-C
D-sub
HDMI
Display
LCD Monitor No Display Monitor Output
Free monitor software available
**Monitor is not included
Power Supply
AC

DC

Smart Configuration & Logging Manage settings, print reports, and log CSV data with our free LINKSHIP software

 > Go to LINKSHIP Page 

CSV Logging


Logging at specified intervals. Custom logger software is also available.

Compare Settings


Compare and verify multiple configuration lists.

Save & Copy via PC


Prevents manual entry errors; reduces management time and costs.

Prevent Misoperation


Configure and verify on screen to prevent accidental button presses on the device.

Reduce Setup Steps


Simply copy master settings and write data to multiple units.

USB Type-C Standard Equipment: Settings *HT/HTL-24 also supports logging and power supply

HT/HTL-24
HT-48
Custom Products


Handy External Configurator (No PC required) (Sold separately)

> PL-5A Product Page
*For configuration only; data logging and power supply are not supported.

Easy Wiring & Installation

[HT/HTL-24]

Pluggable Connectors
Wire to the connector for easy attachment/detachment.

Pluggable Connectors
Spring-lock type


Pluggable Connectors
M2 screw type

Fixed Connectors also available
[Custom Support]


Easy attachment/detachment
Mounting hooks (Left/Right)


Versatile Use Cases

[HT/HTL-24]

Portable Measurement

Carry PCs, tablets, this unit, and cables for USB-powered measurement. Storage case BXS-1 (sold separately) is available.



> BXS-1 Overview

Panel Embedding

24x48 size contributes to downsizing.


> HT-24 Dimensions

DIN Rail Mounting

One-touch mounting fixtures and models without displays are available.

BXF-DN2
DIN Rail Fixture (Sold Separately)
HT-2451
No Display
HT-2431
With Display
> BXF-DN2 Page > 2451 / 2431 Explanation

Specification Examples

Name Thermocouple Meter
Model HT-2401 / HT-2411 / HT-2431 / HT-2451
Input Section
Inputs 1 Channel Thermocouple: K / J / R / E / T / B / N / S
Measurement Range
Type Range A (0.1°C) Range B (1°C) Accuracy*
K -170.0 to 1370.0°C -250 to 1370°C ±0.5% FS
J -200.0 to 1100.0°C -200 to 1100°C ±0.5% FS
R 100.0 to 1760.0°C -50 to 1760°C ±0.5% FS
E -140.0 to 1000.0°C -260 to 1000°C ±0.5% FS
T -240.0 to 400.0°C -270 to 400°C ±0.5% FS
B 480.0 to 1820.0°C 100 to 1820°C ±0.5% FS
N 580.0 to 940.0°C -220 to 1320°C ±0.5% FS
S 450.0 to 1760.0°C 50 to 1760°C ±0.5% FS
*Accuracy specified with output update rate set to 100ms. ※Measurable at 0.1°C resolution within measurement range.
Cold Junction Error ±2°C
Resolution Range A: 0.1°C / Range B: 1°C
Burnout Indication Displays "bAhn" in 7-segment characters on the display.
Calibration Adjustable via zero/span reference voltage inputs for each thermocouple type (Commands via CAN/USB).
Calculation Section
Moving Average Count 1 - 99 (Display moving average: 1 - 9)
Control Input None or 1 Channel (depends on model) [D2] option adds 2 channels
(Settings) Functions configured per control input (CTL) for external control.
[Functions] Hold (Current, Max, Min, Max Peak-to-Peak) / Zero Shift
(Operation) Reflected by shorting (or opening) the control input (CTL*) terminal (ON logic) to GND.
(Data Comm.) Command control available via communication (USB, CAN, RS-485). *Commands set via communication cannot be cleared via terminal inputs; a reset execution is required.
Memory Backup Non-volatile memory (EEPROM)
Display Section
Display (Numeric) 5-digit 7-segment LED, 9mm character height HT-24: Red LED / HT-24-G: Green LED (Option)
Display range: -19999 to 99999 Overflow: OL Zero display: Leading zero suppression
Display update rate: 0.3 sec (configurable from 0.1 to 9.9 sec) Display accuracy: 20ppm ± 1 digit at 23°C
Decimal Point Semi-fixed, configured in program mode (0: □□□□□, 1: □□□□.□ to 4: □.□□□□)
Display (Indicator) 1 LED, configurable for Power / Control Input
USB Communication Section
USB Comm. Specs USB 2.0 (Serial port communication via USB Virtual COM, 230.4kbps)
USB Comm. Functions Read/Write settings / Continuous measurement data output
Update Rate 2ms - 9999ms (configurable in 2ms steps)
General Specifications
Operating Temp/Humid -10°C to +50°C, 35 to 85%RH (non-condensing)
Power Supply 7-60 VDC (with reverse polarity protection) / USB host power: 5V
Power Consumption 3W or less
Isolation Power supply / Thermocouple input / Other inputs & outputs
Withstand Voltage Power supply / Thermocouple input / Other inputs & outputs: 500 VDC for 1 minute between terminals
Weight Approx. 60g
CAN Option
Comm. Specs CAN 2.0B, 10k / 20k / 50k / 100k / 250k / 500k / 1M bps Format (INTEL/MOTOROLA), Frame (11-bit/29-bit)
Comm. Functions Read/Write settings / Continuous measurement data output
Config Items CAN Transmit ID, CAN Receive ID
Update Rate 2ms - 9999ms (configurable in 2ms steps)
RS-485 Option Please consult us for Modbus RTU support
Max Connections 32 units (max)
Comm. Format 2-wire multi-drop serial communication
Comm. Method Asynchronous
Comm. Standard RS-485
Baud Rate 9600bps / 19200bps / 38400bps (configured in program mode)
Data Format Start bit: 1-bit / Stop bit: 1-bit / Data length: 8-bit / Parity: None
Comm. Code ASCII
Comm. Functions Read/Write settings / Measurement data output (responds to request commands)
Analog Output Option
Output Signals [E1] 0 - 10V [E5] 0 - 5V [R1] ±10V [R5] ±5V [I1] 4 - 20mA 【Select Model】
D/A Conversion DAC conversion method
Resolution 16-bit (50,000 or more)
Load Resistance Voltage output: 4.7kΩ or more Current output: 300Ω or less
Accuracy Voltage output: ±0.1% of FS @23°C Current output: ±0.1% of FS @23°C
Temp Drift ±200ppm/°C or less
Output Scaling Custom scaling available via full-scale and zero-scale configurations
Update Rate 2ms - 9999ms (configurable in 2ms steps)
Response Time 1ms or less (0 to 90% response)
Comparator (Alarm) Output Option
Config Method Configured in program mode
Outputs 2 channels / 4 channels (depending on model selection conditions)
Output Form Isolated solid-state output (PhotoMOS relay), non-polarized. Resistance between COMP-COM is 50Ω or less when comparator condition is ON.
Load Voltage Peak AC/DC 280V, 100mA (resistive load). Max ON resistance 50Ω or less.
Output Logic Comparisons performed with polarity (0 is greater than minus numbers).
[Hi-Limit] ON at or above set value
[Lo-Limit] ON at or below set value
[In-Range] ON within range, OFF out of range
[Out-Range] ON out of range, ON within range
Update Rate Depends on analog output update rate configuration. Response time 1ms (max).

Other Related Products Panel Meters / Signal Converters / Indicators

Product List >
EX Series Series List >

- CAN Output - 16-bit Analog (Voltage/Current) Output
- USB Type-C: Settings & Data Logging
- Alarm Output / RS-485
- Free Setup Software: Report printing & data logging
- Dual Analog Outputs [EX48]
- Ethernet (LAN) [EX48]

Load Cell / Pressure / Strain
CAN Conversion
DC Current
DC Voltage
Thermocouple (Temp)
Thermistor (Temp)
RTD (Temp)
Resistance
Speed / Totalizer
Freq Deviation / Torque

EX48

EX(L)24