Ohmmeters & Potentiometer Converters Lineup (Digital Panel Meters, Signal Converters, Indicator Alarms)

For Displacement Sensors, Resistance Output Sensors, etc.

The scaling rate can be set arbitrarily, making it ideal for use in combination with potentiometer-type displacement sensors or resistance-output temperature sensors.
Converts resistance values from potentiometers and linear displacement sensors to CAN signals. Also perfect for CAN signal conditioner applications.

Input
Potentiometers, Internal Resistance, etc.

Sensor Power Supply
・12V / 5V / Others
Arithmetic Operations
・Moving Average (Max 99) ・Zero Shift
・HOLD [Current / Max / Min / Max Peak-to-Peak]
Ohmmeters
   
Output
・16-bit Analog ・Alarm Output
・CAN ・RS-485 ・Modbus ・USB
PC, PLC, Logger, Oscilloscope, Indicator Lights, etc.

Applications

 View All Applications > 

Resistance Value to CAN Conversion

 Details > 


Valve Opening (Angle) Measurement & Monitoring

 Details > 


Resistance Measurement in Wind Tunnel Testing: Vehicles, Architecture, Civil Engineering, etc.

 Details > 

Features

Input Ranges
150Ω / 1.5kΩ / 10kΩ / 40kΩ

*Switchable via program settings
Range 150Ω 1.5kΩ 10kΩ 40kΩ
Measuring Range 0-160Ω 0-1.6kΩ 0-10kΩ 0-40kΩ
Open-Circuit Voltage 3.3V
Measuring Current 1000μA 100μA 50μA
Accuracy Error Rate ±0.02%FS
Min Resolution 0.01Ω 0.1Ω 0.5Ω 1.5Ω

2-Point Scaling Rate Setup
(Linear Compensation Formula)

Versatile Applications

Resistance-to-CAN Conversion
Resistance Measurement
Position Measurement & Control
Angle Measurement & Control
Internal Resistance Measurement
Potentiometer Conversion
CAN Output for Measured Values [Optional]
Continuous CAN Output Function Easily acquire measured values as digital data.

Output Update Rate Up to 1ms refresh rate.

Compatible with SAE J1939 (DLC 8 bytes or less), etc. *Please consult us.
16-bit Analog Output [Optional]

Up to 1ms output refresh rate *40ms for RRL

0-10V
0-5V
±10V
±5V
4-20mA
*Select from the 5 options above when ordering.
Alarm Output [Optional]
High (>=)
Low (<=)
In Range
Out of Range

USB Type-C [Standard]

Data logging & configuration
*Bus power support available for RR(L)-24

RS-485 [Optional]

Modbus RTU [In Development]

Product Lineup

 Details > 

RR-4801

48x96mm Size

Analog Output & Digital Communication
1-9999ms refresh rate

Power Supply
AC100-240V / DC9.6-30V

Display 6 digits
Green LED type also available

Dimensions W96, H48, D99 mm

Front configuration buttons

 Details > 

RR-24

24x48mm Size

Analog Output & Digital Communication
1-9999ms refresh rate

Power Supply
DC7-60V / USB 5V power supply

Display 5 digits
Green LED type also available

Dimensions W48, H24, D106 mm
24x48 DIN size

DIN rail mounting support

 Details > 

RRL-24

24x48mm Size (Economy Model)

Analog Output & Digital Communication
40-9999ms refresh rate

Power Supply
DC7-30V / USB 5V power supply

Display 5 digits
Red LED only

Dimensions W48, H24, D106 mm
24x48 DIN size

DIN rail mounting support



 Details > 

With SD Logger

Saves log data to SD card

Front Buttons
Log Start / Stop

1-Channel Input

Output Options
CAN
16-bit Analog (Volt/Current)
Alarm Output
Ethernet
HDMI

Power Supply
AC100V / DC8-30V, etc.
Selectable Connectors
BNC / M8 / Terminal Block, etc.


 Details > 

Compact Multi-CH

Lightweight, ideal for in-vehicle applications

Multi-Channel Input Custom-build model

Output Options
CAN
16-bit Analog (Volt/Current)
Alarm Output
Ethernet
HDMI

Power Supply DC8-30V
Display Option Available / None
Selectable Connectors
BNC / LAN / D-sub / Terminal Block

Customization Available [Please consult us]

 View List > 
Flexible Measurement Types & Channels

Available from 1 Unit
Convenient, Easy & Low Cost

Calibratable as an Embedded Module
Functional Modifications: Power supply, output voltage, communication specs, etc.

Calibration Documents & Traceability Charts Issuable

Customization Examples [Available for purchase]

Enclosure

 Details > 

Multi-CH with Display

 Details > 

Multi-CH Radiation Thermometer (CAN Output)

 Details > 

With SD Logger

 Details > 

Rack Mountable

 Details > 

Handy Type

 Details > 

Selectable Connectors, Display Options, and Power Supplies

Connectors
Terminal Block
For Thermocouple
Banana Jack
BNC
       
LAN
USB-C
D-sub
HDMI
Display
LCD Monitor Without Display Monitor Output
Free Monitor Software Included
**Monitor is not included
Power Supply
AC

DC

Smart Configuration & Data Logging Manage settings, print reports, and log data to CSV with the free dedicated software LINKSHIP

 Go to LINKSHIP Page > 

CSV Data Logging


Logs data at custom intervals (seconds). Custom logging software is also available.

Compare & Verify Settings


Compare and verify multiple setting profiles side by side.

Save & Copy Settings via PC


Prevents manual entry/handwritten errors, reducing management time and cost.

Prevent Misoperation


Configure and check settings on the PC screen to prevent accidental button presses on the device.

Reduce Setup Hours


Simply copy master settings and write the configuration data to multiple units.

USB Type-C Equipped as Standard: For Configuration *RR/RRL-24 also supports data logging and bus power.

RR/RRL-24
RR-48
Customized Products


Handy External Configurator (No PC Required) (Sold Separately)

> PL-5A Product Page
*For configuration only. Data logging and power supply are not supported.

Easy Wiring & Mounting

[RR/RRL-24]

Pluggable Connectors
Wire to the connector for quick detachment.

Pluggable Connectors
Spring-lock type


Pluggable Connectors
M2 screw type

Fixed Connectors also available
[Custom Option]


Easy body attachment
Mounting hooks (Left & Right)


Variety of Applications

[RR/RRL-24]

Portable Measurement

Carry your PC/tablet, the device, and cables to measure using USB bus power. Carrying Case BXS-1 (sold separately) is also available.



> BXS-1 Overview

Panel Integration

The compact 24x48 size contributes to space-saving equipment designs.


> RR-24 Dimensions

DIN Rail Mounting

One-touch mounting fixtures and models without displays are available.

BXF-DN2
DIN Rail Fixture (Sold Separately)
RR-2451
Without Display
RR-2431
With Display
> BXF-DN2 Page > View Description for 2451 & 2431

Specifications Example

Product Name Ohmeter (Resistance Meter)
Model RR-2401 / RR-2411 / RR-2431 / RR-2451
Input Section
Number of Inputs 1 point
Measurement Range: 150Ω / 1.5kΩ / 10kΩ / 40kΩ
Range 150Ω 1.5kΩ 10kΩ 40kΩ
Measurement Range 0-160Ω 0-1.6kΩ 0-10kΩ 0-40kΩ
Open-circuit Voltage 3.3V
Measurement Current 1000μA 100μA 50μA
Accuracy Error Rate ±0.02% F.S.
Min Resolution 0.01Ω 0.1Ω 0.5Ω 1.5Ω

Sensor Power Output Option: [H] DC +12V±5% 60mA max / [L] DC +5V±5% 150mA max *Sensor power is not output during USB bus power delivery.
Arithmetic Section
Operation Method ΔΣ A/D Conversion Method
Moving Average Count 1 - 99 (Display moving average count is 1 - 9)
Control Input None or 1 point (depending on model) / 2 points added with [D2] option
(Configurable Functions) Assign functions to each control input (CTL) for external control.
[Functions] Hold (Current value, Max value, Min value, Max peak-to-peak fluctuation range), Zero shift
(Operation Method) Short-circuiting the control input (CTL*) terminal (ON logic) to GND activates the control; opening it deactivates/reflects settings.
(Data Communication) Command control supported via communications (USB, CAN, RS-485). *Commands set via communication cannot be cleared via terminal inputs. A system reset is required.
Memory Storage Non-volatile memory (EEPROM)
Display Section
Display (Numeric) 5-digit, 7-segment LED, Character Height: 9mm / RR-2401: Red LED / RR-2401-G: Green LED (Option)
Display Range: -19999 to 99999 / Over-range Display: OL / Zero Display: Leading zero suppression
Display Update Time: 0.3 sec (configurable from 0.1 to 9.9 sec) / Display Moving Average: 1 time (configurable from 1 to 9 times)
Decimal Point Position Semi-fixed, configured in program mode. 0: □□□□□, 1: □□□□.□ to 4: □.□□□□
Display (Indicator) 1 LED, configurable from power status / control input
USB Communication Section
USB Specs USB 2.0 (Serial port communication via USB Virtual COM, 230.4 kbps)
USB Functionality Read/Write setting values / Continuous measurement data output
Output Update Time 1ms - 9999ms (configurable in 1ms increments)
General Specifications
Operating Temp/Humidity -10°C to +50°C, 35 to 85% RH (Non-condensing)
Supply Voltage DC 7-60V, Reverse connection protection included / Power via USB host: 5V
Power Consumption 3W or less
Isolation Between Power Supply / Ohmmeter Input / Other I/Os
Withstand Voltage Between Power Supply / Ohmmeter Input / Other I/Os: DC 500V for 1 minute between each terminal
Weight Approx. 60g
CAN Option
Communication Specs CAN 2.0B, 10 k / 20 k / 50 k / 100 k / 250 k / 500 k / 1M bps / Formats (INTEL/MOTOROLA) / Frames (11-bit/29-bit)
Communication Functions Read/Write setting values / Continuous measurement data output
Configuration Items CAN Tx ID, CAN Rx ID
Output Update Time 1ms - 9999ms (configurable in 1ms increments)
RS-485 Option Please consult us for Modbus RTU support
Max Connections 32 units (max)
Connection Type 2-wire multi-drop serial communication
Communication Mode Asynchronous
Standard RS-485
Baud Rate 9600bps / 19200bps / 38400bps (configured in program mode)
Data Format Start bit: 1-bit / Stop bit: 1-bit / Data length: 8-bit / Parity bit: None
Communication Code ASCII
Communication Functions Read/Write setting values / Measurement data output (responds to request commands)
Analog Output Option
Output Signals [E1] 0 - 10V / [E5] 0 - 5V / [R1] ±10V / [R5] ±5V / [I1] 4 - 20mA [Select Model Type]
D/A Conversion DAC method
Output Resolution 16-bit (over 50,000 counts)
Load Resistance Voltage output: 4.7kΩ or more / Current output: 300Ω or less
Output Accuracy Voltage output: ±0.1% of F.S. @23°C / Current output: ±0.1% of F.S. @23°C
Temperature Drift ±200ppm/°C or less
Output Scaling Custom scaling available via full-scale and zero-scale configurations
Output Update Time 1ms - 9999ms (configurable in 1ms increments)
Comparator (Alarm/Alert) Output Option
Configuration Method Configured in program mode
Number of Outputs 2 points / 4 points (depending on model selection conditions)
Output Form Isolated solid-state output (PhotoMOS relay), non-polarized / Resistance between COMP-COM is 50Ω or less when comparator operation condition is ON
Output Load Voltage Peak AC/DC 280V 100mA (Resistive load) / Max ON resistance: 50Ω or less
Output Logic Comparison performed with polarity (0 is greater than negative value)
[High / Above] ON when value is greater than or equal to setting
[Low / Below] ON when value is less than or equal to setting
[Go / Within Range] ON within the range, OFF outside the range
[Out of Range] ON outside the range, ON within the range
Update Time Depends on analog output update time settings / Max response time: 1ms

Other Related Products Panel Meters / Signal Converters / Indicators

To Product List >
EX Series To Series List >

- CAN Output
- 16-bit Analog (Voltage/Current) Output
- USB-C: Configuration & Data Logging
- Alarm Output / RS-485
- Configuration Management Software (Free): Report Printing & Data Logging
- Dual Analog Outputs [EX48]
- Ethernet (LAN) [EX48]

Load Cell / Pressure / Strain
CAN Conversion
DC Current
DC Voltage
Thermocouple (Temp)
Thermistor (Temp)
RTD (Temp)
Resistance
Speed / Totalizer
Freq Deviation / Torque

EX48

EX(L)24
> Inquiry Form