Coco Research - Measuring Instrument Manufacturer
Products
Applications
Technical Info
Support
Company
Careers
Contact
PAGE
TOP

DC Voltmeter Lineup (Digital Panel Meter / Signal Converter / Indicator Alarm Meter / Distributor)

For Real-Time Voltage Measurement and Feedback Control

Measures average voltage per output update time using a Sigma-Delta AD converter with approx. 250 kHz oversampling.
The rate can be configured arbitrarily. Ideal for scaling meter applications with versatile input ranges, hold, and control functions.

[NEW] Now available with a ±30V measurement range type
Input
Voltage Signals

Pressure sensors, displacement sensors, ECUs, level sensors, etc.
 
Calculation
• Moving Average (Up to 99) • Low-cut
• HOLD [Current / Max / Min / Max Peak-to-Peak]
• Zero/Span Shift • Zero/Span Set
DC Voltmeter
   
Output
• 16-bit Analog • Alarm
• CAN • RS-485 • Modbus • USB
PCs, PLCs, loggers, oscilloscopes, indicator lights, etc.

Applications

 View All Applications > 

Current and Voltage Measurement in ECU Development

 Details > 


Voltage to CAN Conversion

 Details > 


Measurement and Monitoring of Valve Opening (Angle)

 Details > 


Water Level Measurement & Control for Tanks: Using Distributor

 Details > 

Key Features

13 Input Range Models, 10.4 ns Input Resolution

Select input range upon ordering (Contact us for ranges other than below)

±70V
±30V
±20V
±10V
±5V
±2V
±1V
±200mV
±100mV
±20mV
±10mV
1(0)-5V*
0-10V*
*Process signals supported

2-Point Rate Setting
(Linear Compensation)

For Various Applications

Voltage-CAN Conversion
DC Voltage Measurement
Pressure Measurement
Displacement Measurement
Flow Measurement
CAN Output for Measured Values [Option]
CAN Continuous Output Function Easily obtain measured values as digital data

Output Update Up to 1 ms refresh rate

Examples of compatibility include SAE J1939 (DLC 8 bytes or less) *Please consult us
16-bit Analog Output [Option]

Up to 1 ms output update refresh rate *PSVL is 40 ms

0-10V
0-5V
±10V
±5V
4-20mA
*Select from the 5 options above upon ordering
Alarm Output [Option]
Upper Limit
Lower Limit
In-Range
Out-of-Range

USB Type-C [Standard]

Data logging & configuration
*PSV(L)-24 can also be bus-powered

RS-485 [Option]

Modbus RTU [Coming Soon]

Lineup

 Details > 

PSV-4801

48x96mm Size

Analog Output & Digital Comm.
1-9999ms refresh rate

Power Supply
AC100-240V / DC9.6-30V

Display 6 Digits
Green LED type also available

Dimensions W96, H48, D99 mm

Front Configuration Buttons

 Details > 

PSV-24

24x48mm Size

Analog Output & Digital Comm.
1-9999ms refresh rate

Power Supply
DC7-60V / USB 5V Bus Power

Display 5 Digits
Green LED type also available

Dimensions W48, H24, D106 mm
24x48 DIN Size

DIN Rail Mounting Supported

 Details > 

PSVL-24

24x48mm Size (Economy Model)

Analog Output & Digital Comm.
40-9999ms refresh rate

Power Supply
DC7-30V / USB 5V Bus Power

Display 5 Digits
Red LED Only

Dimensions W48, H24, D106 mm
24x48 DIN Size

DIN Rail Mounting Supported



 Details > 

With SD Logger

Saves Logging Data to Card

Front Buttons
Start / Stop Logging

1-Channel Input

Output
CAN
16-bit Analog (Voltage/Current)
Alarm
Ethernet
HDMI

Power Supply
AC100V / DC8-30V, etc.
Selectable Connectors
BNC / M8 / Terminal Block, etc.


 Details > 

Compact Multi-CH

Lightweight, Ideal for In-Vehicle Use

Multi-Channel Input (Customized product)

Output
CAN
16-bit Analog (Voltage/Current)
Alarm
Ethernet
HDMI

Power Supply DC8-30V
Display Choice with or without
Selectable Connectors
BNC / LAN / D-sub / Terminal Block

Customization Available[Please contact us]

 View List > 
Flexible Measurement Types & Channels

Available from a Single Unit
Convenient, Simple, & Low Cost

Calibratable as an Embedded Component
Specification Changes: Power supply, output voltage, communication protocol, etc.

Calibration Documents & Traceability Charts Available

Customization Examples [Available for purchase]

Enclosed / Box Type

 Details > 

Multi-CH with Display

 Details > 

Multi-CH Radiation Thermometer (CAN Output)

 Details > 

With SD Logger

 Details > 

Rack-Mount Integrated

 Details > 

Handy / Portable Type

 Details > 

Selectable Connectors, Display Options, and Power Supplies

Connectors
Terminal Block
For Thermocouple
Banana Jack
BNC
       
LAN
USB-C
D-sub
HDMI
Display Options
LCD Monitor No Display External Monitor
Free monitoring software included
**Monitor not included
Power Supply
AC

DC

Smart Configuration & Logging Manage settings, print reports, and log to CSV with the free dedicated software "LINKSHIP"

 Go to LINKSHIP Page > 

CSV Data Logging


Logging at user-specified intervals (in seconds). Custom logger software available.

Compare & Verify Settings


Compare and verify multiple configuration lists.

Save & Copy Settings via PC


Prevents manual entry errors while reducing management effort and costs.

Prevent Operational Errors


Configure and verify directly on the PC screen to prevent accidental key presses on the unit.

Reduce Configuration Time


Simply copy the master configuration data and write it to multiple units.

Standard USB Type-C Port for Setup *PSV/PSVL-24 also supports data logging and bus power

PSV/PSVL-24
PSV-48
Customized Product


Handy External Configurator (No PC required) (Sold separately)

> Go to PL-5A Product Page
*For configuration only. Data logging and power supply functions are not supported.

Easy Wiring & Mounting

[PSV/PSVL-24]

Pluggable Connectors
Wire to the plug for easy connection

Pluggable Connectors
Spring-lock type


Pluggable Connectors
M2 screw type

Fixed Connectors also available
[Custom Support]


Easy attachment/detachment
Mounting Hooks (Left/Right)


Versatile Applications

[PSV/PSVL-24]

Portable Measurement

Carry your PC/tablet, the device, and cables for USB-powered measurement. Storage case BXS-1 (sold separately) is also available.



> BXS-1 Overview

Panel Integration

Compact 24x48 size contributes to space saving.


> PSV-24 Dimensions

DIN Rail Mounting

One-touch mounting fixtures and models without display are available.

BXF-DN2
DIN Rail Mounting Fixture (Sold separately)
PSV-2451
Without Display
PSV-2431
With Display
> Go to BXF-DN2 Page > View Description for 2451 & 2431

Specifications Example

Model PSV-2401 / PSV-2411 / PSV-2431 / PSV-2451
Input Signal DC Voltage Signal
Operation Method ΔΣ Integration Method
Input Section
Number of Inputs 1 point
Measurement Range
Type Voltage Measurement Range
±70V -70000 to +70000mV
±30V -30000 to +30000mV
±20V -20000 to +20000mV
±10V -10000 to +10000mV
±5V -5000.0 to +5000.0mV
±2V -2000.0 to +2000.0mV
±1V -1000.0 to +1000.0mV
±200mV -200.00 to +200.00mV
±100mV -100.00 to +100.00mV
±20mV -20.000 to +20.000mV
±10mV -10.000 to +10.000mV
1-5V +1000.0 to +5000.0mV
0-10V 0 to +100000mV
*Please contact us for other measurement ranges.
Accuracy ±0.1% FS + 1 digit
Oversampling Fixed at 250kHz
Input Low-Pass Filter Cutoff Frequency: 1kHz
Sensor Power Output Option: [H] DC +12V±5% 60mA max / [L] DC +5V±5% 150mA max Sensor power is not output during USB bus power.
Arithmetic Section
Moving Average Count 1 - 99
Low Cutoff Evaluates to 0 for voltage values below the set threshold.
Control Input None or 1 point (depending on model) [D2] Option adds 2 points
(Configuration) Configure functions for each control input (CTL) to manage via external control.
[Functions] Hold (Current, Max, Min, Max Peak-to-Peak fluctuation), Zero Shift, Span Shift, Zero Set, Span Set
[ON Logic] Normally Open, Normally Closed
(Operation Method) Shorting (opening) the control input (CTL*) terminal (ON logic) to GND turns it ON, and opening (shorting) applies the configured settings.
(Data Communication) Command control via communication is supported (USB, CAN, RS-485) *Commands configured via communication cannot be canceled via terminal input. A hardware reset is required.
Control Input Response Response time can be configured (1ms to 1999ms)
Control Input Backup Enables/disables backup of values during shift and set operations (retains values even when powered off).
Setting Retention Non-volatile memory (EEPROM)
Display Section
Display (Numeric) 5-digit, 7-segment LED, Character Height: 9mm PSV-2401: Red LED / PSV-2401-G: Green LED (Option)
Display Range: -19999 to 99999 Polarity Display: "-" lights up during reverse rotation
Over-range Display: OL Zero Display: Leading zero suppression
Display Update Time: 0.3 seconds (configurable from 0.1 to 9.9 seconds) Display Accuracy: 20ppm ± 1 digit at 23℃
Decimal Point Position Semi-fixed, configured in program mode. 0: □□□□□ 1: □□□□.□ to 4: □.□□□□
Display (Indicator) 1 LED, configured from Power / Control Input
USB Communication Section
USB Comm. Specs USB 2.0 (Serial port communication via USB Virtual COM at 230.4kbps)
USB Comm. Functions Write/Read settings, continuous measurement value output
Output Update Time 1ms - 9999ms (Configurable in 1ms increments)
General Specifications
Operating Temp/Humidity -10℃ to +50℃, 35 to 85% RH (Non-condensing)
Power Supply Voltage DC 7-60V (With reverse connection protection), USB Host Power: 5V
Power Consumption 3W or less
Isolation Between Power / Voltage Input / Other Inputs & Outputs
Weight Approx. 60g
CAN Option
Comm. Specs CAN 2.0B 10k / 20k / 50k / 100k / 250k / 500k / 1M bps, Formats (INTEL/MOTOROLA), Frames (11-bit/29-bit)
Comm. Functions Write/Read settings, continuous measurement value output
Configurable Items CAN Transmit ID, CAN Receive ID
Output Update Time 1ms - 9999ms (Configurable in 1ms increments)
RS-485 Option Please contact us for Modbus RTU support as well.
Max Connections 32 units (max)
Connection Type 2-wire multi-drop serial communication
Comm. Method Asynchronous
Comm. Standard RS-485
Baud Rate 9600bps / 19200bps / 38400bps (Configured in program mode)
Data Format Start bit: 1-bit / Stop bit: 1-bit / Data length: 8-bit / Parity: None
Comm. Code ASCII
Comm. Functions Write/Read settings, measurement value output (responds to request commands)
Analog Output Option
Output Signal [E1] 0 - 10V [E5] 0 - 5V [R1] ±10V [R5] ±5V [I1] 4 - 20mA 【Select Model】
D/A Conversion DAC Method
Output Resolution 16-bit (50,000 or more)
Load Resistance Voltage Output: 4.7kΩ or higher Current Output: 300Ω or lower
Output Accuracy Voltage Output: ±0.1% of FS @ 23℃ Current Output: ±0.1% of FS @ 23℃
Temperature Drift ±200ppm/℃ or less
Output Scaling Arbitrary scaling possible via Full Scale and Zero Scale settings
Output Update Time 1ms - 9999ms (Configurable in 1ms increments)
Comparator (Alarm) Output Option
Configuration Configured in program mode
Number of Outputs 2 points / 4 points (depending on model selection criteria)
Output Form Isolated solid-state output (PhotoMOS relay), non-polarized. When comparator operation condition is ON, resistance between COMP-COM is 50Ω or less.
Output Load Voltage Peak AC/DC 280V 100mA (Resistive load), ON Resistance: Max 50Ω or less
Output Logic Comparison is performed with polarity (0 is greater than negative).
[High] ON when at or above the set value
[Low] ON when at or below the set value
[Inside Range] ON within the range, OFF outside the range
[Outside Range] ON outside the range, OFF within the range
Update Time Based on analog output update time configuration. Response time: 1ms (max)

Other Related Products Panel Meters / Signal Converters / Indicators

To Product List >
EX Series To Series List >

- CAN Output
- 16-bit Analog (Voltage/Current) Output
- USB-C: Configuration & Data Logging
- Alarm Output / RS-485
- Configuration Management Software (Free): Report Printing & Data Logging
- Dual Analog Outputs [EX48]
- Ethernet (LAN) [EX48]

Load Cell / Pressure / Strain
CAN Conversion
DC Current
DC Voltage
Thermocouple (Temp)
Thermistor (Temp)
RTD (Temp)
Resistance
Speed / Totalizer
Freq Deviation / Torque

EX48

EX(L)24