COCORESEARCH, Measuring Instrument Manufacturer
Products
Applications
Technical Info
Support
Company
Careers
Inquiry
Back to
Top

NTC Thermistor Thermometer List
Temperature Measurement Panel Meter / Signal Converter

High Conversion Accuracy with Original Calculation Method
B2 Constant Logarithmic Approximation Algorithm

Measures temperature in combination with NTC thermistors, and outputs via voltage/current signals or CAN.

Input
NTC Thermistor

 
Calculation
・Moving Average (Max 99) ・Zero Shift
・HOLD [Current / Max / Min / Max Fluctuation Range]
Thermistor Thermometer
   
Output
・16-bit Analog (Voltage/Current) ・Alarm
・CAN ・RS-485 ・Modbus ・USB
PC, PLC, Logger, Oscilloscope, Indicator, etc.

Application Examples

 To Application List > 

Temperature Detection & Control for Electrical Appliances and Batteries

 View Details > 

Converting Thermistor (Temperature) to CAN

 View Details > 

Features

Within ±0.05% rdg Conversion Accuracy
via B2 Constant Logarithmic Approximation Algorithm
@ 0°C to 150°C


Within ±0.5% rdg Conversion Accuracy at 0°C to 100°C /
Within ±3% rdg at 100°C to 150°C
via B1 Constant Logarithmic Approximation Algorithm

Resistance Measurement Error
±0.02%
FS @ 23°C

CAN Output of Measured Values [Option]
CAN Continuous Output Function Easily acquire measured values as digital data

Output Update Fastest 1 ms update

Examples of compatibility include SAE J1939 (DLC 8 bytes or less) *Please consult us
16-bit Analog Output [Option]

Fastest 1 ms output update *40 ms for HTL

0-10V
0-5V
±10V
±5V
4-20mA
*Select from the 5 types above when ordering
Alarm Output [Option]
Over
Under
Within Range
Out of Range

USB Type-C [Standard]

Data Logging & Configuration
*HT(L)-24 can also be powered via USB

RS-485 [Option]

Modbus RTU [Under Development]

Lineup

 View Details > 

HT-24T

24x48mm Size

Analog Output & Digital Communication
1-9999 ms update

Power Supply
DC7-60V / USB Power 5V

Display 5 Digits
Green LED type also available

Dimensions W48, H24, D106
24x48 DIN Size

DIN Rail Mounting Support

 View Details > 

HTL-24T

24x48mm Size (Low-Cost Version)

Analog Output & Digital Communication
40-9999 ms update

Power Supply
DC7-30V / USB Power 5V

Display 5 Digits
Red LED only

Dimensions W48, H24, D106
24x48 DIN Size

DIN Rail Mounting Support



 View Details > 

With SD Logger

Save Logging Data to Card

Front Buttons
Start / Stop Logging

1-Channel Input

Output
CAN
16-bit Analog (Voltage/Current)
Alarm
Ethernet
HDMI

Power Supply
AC100 / DC8-30V, etc.
Selectable Connectors
BNC / M8 / Terminal Block, etc.


 View Details > 

Compact Multi-Channel

Lightweight, Ideal for On-Vehicle Use

Multi-Channel Input (Customizable)

Output
CAN
16-bit Analog (Voltage/Current)
Alarm
Ethernet
HDMI

Power Supply DC8-30V
Display Select With / Without
Selectable Connectors
BNC / LAN / D-sub / Terminal Block

Customization Support [Please consult us]

 View List > 
Flexible Measurement Types & Channels

Available from a Single Unit
Convenient, Easy & Low Cost

Calibratable as an Embedded Product
Feature Modifications: Power, Output Voltage, Communication Specs, etc.

Calibration Documents & Traceability Charts Available

Customization Examples [Available for Purchase]

Enclosure / Box Housing

 View Details > 

Multi-CH with Display

 View Details > 

Multi-CH Radiation Thermometer with CAN Output

 View Details > 

With SD Logger

 View Details > 

Rack Mount Integration

 View Details > 

Handy Type

 View Details > 

Selectable Connectors, Displays, Power Supplies, etc.

Connectors
Terminal Block
For Thermocouple
Banana Plug
BNC
       
LAN
USB-C
D-sub
HDMI
Display Options
LCD Monitor Without Display External Monitor Display
Free monitor display software included
**Monitor is not included
Power Supply
AC

DC

Smart Configuration & Logging Manage configurations, print reports, and perform CSV logging with the dedicated free software LINKSHIP

 To LINKSHIP Page > 

CSV Data Logging


Log data at specified intervals. Custom logger software is also available.

Compare & Verify Settings


Compare and verify multiple configuration setting lists.

Save & Copy via PC


Prevents mistakes from handwriting/manual entry, reducing management effort and costs.

Prevent Misoperation


Configure and verify settings on the PC screen to prevent operation mistakes on the unit buttons.

Reduce Configuration Hours


Simply copy the master configuration file and upload the setting data to multiple units.

USB Type-C Standard Equipment: Configuration *HT/HTL-24T also supports logging and power supply

HT/HTL-24T
Customized Products


Handy External Configurator (No PC required) (Sold separately)

> PL-5A Product Page
*Dedicated for configuration only / Data logging and power supply are not supported.

Easy Wiring & Installation

[HT/HTL-24T]

Detachable Plug Connector
Wire to the connector and easily plug in/out

Detachable Plug Connector
Spring-lock type


Detachable Plug Connector
M2 screw type

Fixed Connector also available
[Custom Support]


Easy attachment/detachment
Mounting Hooks (Left & Right)


A Variety of Usage Options

[HT/HTL-24T]

Portable Measurement

Carry your PC, tablet, this unit, and cables to measure using USB power. Storage case BXS-1 (sold separately) is also available.



> To BXS-1 Overview

Panel Integration

24x48 mm size contributes to space saving.


> HT-24T Dimension Drawing

DIN Rail Mounting

One-touch mounting fixtures and non-display models are available.

BXF-DN2
DIN Rail Fixture (Sold separately)
HT-2451T
Without Display
HT-2431T
With Display
> To BXF-DN2 Page > View Description of 2451 / 2431

Specification Examples

Name Thermistor Thermometer
Model HT-2401T / HT-2411T / HT-2431T / HT-2451T
Input Section
No. of Inputs 1 Channel (Thermistor NTC)
Measuring Range 40kΩ
Measurement Scope 0Ω - 40kΩ (Minimum resolution: 1.5Ω)
Open Voltage 3.3V (Measurement current: 50uA)
Resistance Measurement Error ±0.02%FS @23℃
Conversion Accuracy Examples [Algorithm 1] Within ±0.5%rdg at 0℃ to 100℃ / Within ±3%rdg at 100℃ to 150℃
[Algorithm 2] Within ±0.05%rdg at 0℃ to 150℃ (Both Algorithm 1 and 2 apply to Shibaura Electronics PB43 factory default settings. Excludes resistance measurement error.)
Calculation Section
Operation Mode ΔΣ Integration Method
Moving Average Count 1 - 99 (Display moving average count: 1 - 9)
Control Input None or 1 Channel (Depends on model) / 2 additional channels with [D2] option
(Configuration Content) Configure features for each control input (CTL) and control from external sources.
[Features] Selectable from Hold (Current value, Max value, Min value, Max fluctuation range) and Zero Shift.
(Operation Method) Reflected by short-circuiting (opening) the control input (CTL*) terminal (ON logic) to GND.
(Data Communication) Command control available via communication (USB, CAN, RS-485) *Commands set via communication cannot be canceled by terminal input. A reset execution is required.
Setting Value Memory Non-volatile Memory (EEPROM)
Display Section
Display (Numeric Display) 5 Digits, 7-Segment LED (Character height: 9mm) / HT-2401T: Red LED / HT-2401T-G: Green LED (Option)
Display Range: -19999 to 99999 / Over-range Display: OL / Zero Display: Leading zero suppression
Display Update Time: 0.3 sec (Configurable from 0.1 to 9.9 sec) / Display Moving Average: 1 time (Configurable from 1 to 9 times)
Decimal Point Position Semi-fixed, configured via Program Mode (0: □□□□□, 1: □□□□.□ to 4: □.□□□□)
Display (Indicator) 1 LED, configurable from Power Supply / Control Input
USB Communication Section
USB Communication Specs USB 2.0 (Serial port communication via USB virtual COM, 230.4kbps)
USB Communication Features Write/Read configuration values / Continuous output of measured values
Output Update Time 1ms - 9999ms (Configurable in 1ms increments)
General Specifications
Operating Temp/Humidity Range -10℃ to +50℃, 35 to 85%RH (Non-condensing)
Power Supply Voltage DC 7-60V (Reverse connection protection included) / Power from USB host: 5V
Power Consumption 3W or less
Isolation Power Supply / Thermistor Input / Other Inputs and Outputs
Withstand Voltage Power Supply / Thermistor Input / Other Inputs and Outputs: DC 500V for 1 minute between terminals
Weight Approx. 60g
CAN Option
Communication Specs CAN 2.0B 10k / 20k / 50k / 100k / 250k / 500k / 1M bps, Formats (INTEL/MOTOROLA), Frames (11-bit/29-bit)
Communication Features Write/Read configuration values / Continuous output of measured values
Configuration Items CAN TX ID, CAN RX ID
Output Update Time 1ms - 9999ms (Configurable in 1ms increments)
RS-485 Option Please consult us for Modbus RTU compatibility
Max. Connections 32 Units (Max)
Communication Type 2-Wire Multi-drop Serial Communication
Communication Mode Asynchronous Mode
Communication Standard RS-485
Baud Rate 9600bps / 19200bps / 38400bps (Configured via Program Mode)
Data Format Start Bit: 1-bit / Stop Bit: 1-bit / Data Length: 8-bit / Parity: None
Communication Code ASCII
Communication Features Write/Read configuration values / Output measured values (Responds to request commands)
Analog Output Option
Output Signal [E1] 0 - 10V [E5] 0 - 5V [R1] ±10V [R5] ±5V [I1] 4 - 20mA 【Select Model】
D/A Conversion Mode DAC Conversion Method
Output Resolution 16-bit (Over 50,000)
Load Resistance Voltage Output: 4.7kΩ or more / Current Output: 300Ω or less
Output Accuracy Voltage Output: ±0.1% of FS @23℃ / Current Output: ±0.1% of FS @23℃
Temperature Fluctuation ±200ppm/℃ or less
Output Scaling Arbitrary scaling possible via full-scale and zero-scale configurations
Output Update Time 1ms - 9999ms (Configurable in 1ms increments)
Output Response Time 1ms or less (0→90% response)
Comparator (Alarm) Output Option
Configuration Method Configured via Program Mode
No. of Outputs 2 Points / 4 Points (Depends on model selection criteria)
Output Type Isolated Solid-State Output (PhotoMOS Relay), Non-polarized. Resistance between COMP-COM is 50Ω or less when comparator operation condition is ON.
Output Load Voltage Peak AC/DC 280V 100mA (Resistive load), ON resistance max 50Ω or less
Output Logic Comparison is performed with polarity (0 is greater than minus)
[Over] ON at or above set value
[Under] ON at or below set value
[Within Range] ON within set range, OFF out of range
[Out of Range] ON out of set range, ON within range
Update Time Depends on analog output update time settings. Response time: 1ms (max)

Other Related Products Panel Meters / Signal Converters / Indicators

To Product List >
EX Series To Series List >

- CAN Output
- 16-bit Analog (Voltage/Current) Output
- USB-C: Configuration & Data Logging
- Alarm Output / RS-485
- Configuration Management Software (Free): Report Printing & Data Logging
- Dual Analog Outputs [EX48]
- Ethernet (LAN) [EX48]

Load Cell / Pressure / Strain
CAN Conversion
DC Current
DC Voltage
Thermocouple (Temp)
Thermistor (Temp)
RTD (Temp)
Resistance
Speed / Totalizer
Freq Deviation / Torque

EX48

EX(L)24
> Inquiry Form