Verify bearing RPM and rotation speed inside an environmental chamber. Trigger an alarm output in the event of abnormal speed drops, increases, or stops.
Environmental Chamber![]() [A] Bearing |
![]() ![]() ![]() ![]() Pulse Signal |
| Speed/Totalizer [Switchable] SPD Series (4 units) [Example of Housed Customization] ![]() |
![]() Analog Alarm RS-485 CAN USB, etc. |
| PC, PLC, Logger, Oscilloscope, Indicator Lights, etc.
![]() |
|
| Rotation Measurement & Anomaly Detection Without Opening the Chamber |
Conventional Method![]() |
![]() |
|
・Must open the chamber to visually inspect at every check. ・Opening/closing and inspection for long-term tests is labor-intensive. ・Chamber temperature fluctuates every time it is opened. |
This Solution![]() |
|
|
・No need to open the environmental chamber during inspections. ・Allows for at-a-glance confirmation during routine patrols. ・Reduces fluctuations in chamber temperature due to opening/closing. |
Measure multiple samples simultaneously to evaluate performance and variations.
Trigger alerts if rotation speed abnormally increases, decreases, or stops.
Record the history of rotation speeds to facilitate root-cause analysis during anomalies.
■ Analog output can be selected from 0-10V, 0-5V, ±10V, ±5V, and 4-20mA (Optional / Specify at the time of order).
Output update rate is as fast as 0.1 ms (SPD). Full-scale values can also be configured.
■ Alarm (alert) signal can be output when the rotation exceeds specified limits (Optional).
■ Supports both rotation speed and totalizer count measurement (Switchable: simultaneous measurement not available).
■ Supports CAN output for measurement data (Optional).
■ Measurement from 0 Hz.
*Please prepare your own rotation detection sensors.
■ Multiple measurement instruments can be housed together in a single enclosure.
■ Instrument types, quantities, and connector styles can be specified.
■ Calibration and document issuance are also available for housed products.
■ A diverse product lineup supporting rotation speed, temperature, current, voltage, resistance, torque, CAN, etc.
■ Fast update time, analog output (Optional)
■ Fastest 1ms update, CAN output (Optional)
■ Line driver input support, highly resistant to noise during long-distance transmission (Optional)
| Load Cell / Pressure / Strain | CAN Conversion |
| DC Current | DC Voltage |
| Thermocouple (Temperature) | Thermistor (Temperature) |
| RTD (Temperature) | Resistance |
| Speed / Totalizer | Frequency Deviation / Torque |
- CAN Output
- 16-bit Analog (Voltage / Current) Output
- Simultaneous CAN and Analog Output Available (1ms or 40ms update)
- USB-C Standard Equipment: Configuration & Data Logging
- Alarm Output / RS-485
- Free Measurement Management Software: Configuration Management, Report Printing, Data Logging